首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple method for preparing undecalcified thin sections of bone with implants has been developed. After exposing a surface of bone and implant in a plastic block by sawing thick sections, the surface is stained prior to making a thin section. A glass coverslip is affixed with a thin layer of cement to the stained surface to stabilize the tissue and implant during sectioning. A mixture of glycerine and water is used as a coolant and lubricant. The orientation in situ is preserved allowing demonstration of bone architecture and cells, and the tissue-implant interface.  相似文献   

2.
Development of surface treatments has enabled secure attachment of dental implants in less than 1 month. Consequently, it is necessary to characterize accurately the osseointegration of the implant surface in the region of the bone-implant contact (BIC). We developed a method for sample preparation that preserves both bone and BIC to permit analysis of the contact interface. We prepared eight nanotextured implants and implanted them in rabbit tibias. After healing for 30 days, outcomes were analyzed using both our bone preservation protocol and routine decalcification followed by preparation of histological sections stained by hematoxylin and eosin (H & E). Pull-out tests for implant osseointegration were performed after healing. Non-implanted samples of rabbit mandible were used as a control for assessing organic and mineralized bone characteristics and bone structure. Our bone preservation protocol enabled evaluation of many of the same bone characteristics as histological sections stained with H & E. Our protocol enables analysis of implant samples, implant surfaces and osseointegration without risk of BIC damage.  相似文献   

3.
Orthopedic biomaterials currently are made of metal alloy coated with one or more thin layers of dense or porous ceramic or metal. Sections of these materials implanted in human bone were made without altering the implant or bone-implant interfaces. Bone containing an implant was fixed and then embedded in polyme-thylmethacrylate. Thick sections were made using a cooled. low speed diamond saw, then ground and polished. Some were stained by fuchsin-toluidine staining solution, others were acid etched to reveal the structure of the metal contained in the prosthesis. Observation by reflected and transmitted light microscopy revealed microstructure of the implant material as well as features of the surrounding tissues.  相似文献   

4.
A thin sectioning technique involving hand grinding has been developed to produce 20-40-microns-thick sections of bone-titanium implant sites. Components include: 1) surface staining of sections prior to mounting on slides so bone labels (oxytetracycline-HCl and 2,4-bis(N,N-dicarbomethyl)aminomethylfluorescein (DCAF] can be seen in sections viewed with transmitted light, 2) a pneumatic sample press for bonding sections to slides with a thin, uniform glue line and without trapped air bubbles, and 3) bonding methyl methacrylate embedded sections to clear acrylic slides with methyl methacrylate monomer to provide enhanced bond strength and grinding properties compared to those obtainable with glass slides. Sample cracking and distortion is minimized and the tissue-implant interface can be kept intact. The expense of start-up equipment for this technique is minimal.  相似文献   

5.
A thin sectioning technique involving hand grinding has been developed to produce 20—40-μn-thick sections of bone-titanium implant sites. Components include: 1) surface staining of sections prior to mounting on slides so bone labels (oxytetracycline-HCI and 2,4-bis(N,N-dicarbometnyl) aminomethylfluorescein (DCAF)) can be seen in sections viewed with transmitted light, 2) a pneumatic sample press for bonding sections to slides with a thin, uniform glue line and without trapped air bubbles, and 3) bonding methyl methacrylate embedded sections to clear acrylic slides with methyl methacrylate monomer to provide enhanced bond strength and grinding properties compared to those obtainable with glass slides. Sample cracking and distortion is minimized and the tissue-implant interface can be kept intact The expense of start-up equipment for this technique is minimal.  相似文献   

6.
A technique for demonstrating cement lines in thin, undecalcified transverse sections of cortical bone has been developed. Cortical bone samples are processed and embedded undecalcified in methyl methacrylate plastic. After sectioning at 3-5 μm, cross-sections are transferred to a glass slide and flattened for 10 min. Sections of cortical bone are stained for 20 sec free-floating in a fresh solution of 1% toluidine blue dissolved in 0.1% formic acid. The section is dehydrated in t-butyl alcohol, cleared in xylene, and mounted with Eukitt's medium. Reversal lines appear as thin, scalloped, dark blue lines against a light blue matrix, whereas bone formation arrest lines are thicker with a smooth contour. With this technique cellular detail, osteoid differentiation, and fluorochrome labels are retained. Results demonstrate the applicability of a one-step staining method for cement lines which will facilitate the assessment of bone remodeling activity in thin sections of undecalcified cortical bone.  相似文献   

7.
A technique for demonstrating cement lines in thin, undecalcified transverse sections of cortical bone has been developed. Cortical bone samples are processed and embedded undecalcified in methyl methacrylate plastic. After sectioning at 3-5 microns, cross-sections are transferred to a glass slide and flattened for 10 min. Sections of cortical bone are stained for 20 sec free-floating in a fresh solution of 1% toluidine blue dissolved in 0.1% formic acid. The section is dehydrated in t-butyl alcohol, cleared in xylene, and mounted with Eukitt's medium. Reversal lines appear as thin, scalloped, dark blue lines against a light blue matrix, whereas bone formation arrest lines are thicker with a smooth contour. With this technique cellular detail, osteoid differentiation, and fluorochrome labels are retained. Results demonstrate the applicability of a one-step staining method for cement lines which will facilitate the assessment of bone remodeling activity in thin sections of undecalcified cortical bone.  相似文献   

8.
A technique for demonstrating cement lines in thin, undecalcified, transverse sections of cortical bone has been developed. Cortical bone samples are processed and embedded undecalcified in methyl methacrylate plastic. After sectioning at 3-5 microns, cross-sections are transferred to a glass slide and flattened for 10 min. Sections of cortical bone are stained for 20 sec free-floating in a fresh solution of 1% toluidine blue dissolved in 0.1% formic acid. The section is dehydrated in t-butyl alcohol, cleared in xylene, and mounted with Eukitt's medium. Reversal lines appear as thin, scalloped, dark blue lines against a light blue matrix, whereas bone formation arrest lines are thicker with a smooth contour. With this technique cellular detail, osteoid differentiation, and fluorochrome labels are retained. Results demonstrate the applicability of a one-step staining method for cement lines which will facilitate the assessment of bone remodeling activity in thin sections of undecalcified cortical bone.  相似文献   

9.
A new method for preparation of sections of undecalcified bone is described. Samples of ovine bone were embedded in methylmethacrylate and thick-sectioned with a cutoff machine or commercial band saw. Composite slides were prepared by gluing white acrylic to glass using cyanoacrylate glue. Bone sections were glued to the composite slide and then surface polished by grinding or ultramilling. The polished surface of the section was then etched and stained. The techniques described in this paper reduce the time spent grinding or milling sections and improve resolution of surface-stained features of undecalcified bone sections.  相似文献   

10.
A new method for preparation of sections of undecalcified bone is described. Samples of ovine bone were embedded in methylmethacrylate and thick-sectioned with a cutoff machine or commercial band saw. Composite slides were prepared by gluing white acrylic to glass using cyanoacrylate glue. Bone sections were glued to the composite slide and then surface polished by grinding or ultramilling. The polished surface of the section was then etched and stained. The techniques described in this paper reduce the time spent grinding or milling sections and improve resolution of surface-stained features of undecalcified bone sections.  相似文献   

11.
Sections of compact bone were cut from the diaphysis of the femur, tibia, and humerus from dogs and monkeys. These sections were either ground thin and decalcified, or decalcified and subjected to frozen sectioning. Decalcification of the sections was effected by immersion in either Decal, 10% formic acid, 10% formic acid-sodium citrate (pH 4.5) or 20% aqueous EDTA. Sections were routinely stained with oil red O, Sudan black B, or Fettrot 7B. In addition, Nile blue A and phosphine 3R were also employed. Sections stained with phosphine were viewed with a fluorescence microscope. Control sections were extracted with lipid solvents prior to application of the staining procedures. The results indicate that lipid is present in compact bone within the osteocytes, lacunae, canaliculi, and organic matrix. The significance of the lipid in these sites, particularly extracellularly, is unknown.  相似文献   

12.
Aluminum is known to accumulate with age in bone and other tissues of humans, even in the absence of renal disease. Our study aimed to develop a histological staining method sufficiently sensitive to detect aluminum in plastic sections of undecalcified bone biopsies from healthy volunteers as well as from patients with renal and non-renal bone diseases. We used quantitative histomorphometry to measure the percentage of trabecular surface stained by aluminum and found that our new method was approximately 50% more sensitive for detecting aluminum than the Acid Solochrome Azurine (ASA) method which in turn was significantly more sensitive than the Aluminon method. Aluminon is widely used in pathology laboratories for diagnostic purposes despite concerns in the literature about Aluminon's limited sensitivity for aluminum. Our histomorphometric results showed that the newly developed method stained approximately 10% of the trabecular surface in bone sections from healthy controls, 38% from renal patients, 26% from patients with vitamin D deficiency, and 29% from patients with osteoporosis. Histomorphometric measurements of aluminum-stained trabecular surfaces in sections stained with ASA were consistent with those obtained in Walton-stained sections but proportionately lower. Moreover, the Walton and ASA methods stained aluminum at similar locations in adjacent bone sections. As the ASA and Walton methods are considerably more sensitive for bone aluminum than the Aluminon method, we recommend that either of them should be used in place of the Aluminon method for routine diagnostic purposes.  相似文献   

13.
To evaluate the osteogenic potential of novel implant materials, it is important to examine their effect on osteoblastic differentiation. Characterizing the tissue response at the bone-biomaterial interface in vivo at a molecular level would contribute significantly to enhancing our understanding of tissue integration of endosseous implant materials. We describe here a new technique that overcomes difficulties commonly associated with performing immunohistochemistry on undecalcified sawed sections of bone. Sheep mandible specimens were fixed in an ethanol based fixative to maintain adequate antigenicity of the tissue. As a result, it was possible to omit antigen retrieval at high temperature for recovery of antigenicity, and detachment of sections from the slides was avoided. Following dehydration and infiltration, the specimens were embedded in a resin composed of polymethylmethacrylate and polybutylmethacrylate. Polymerization was achieved by adding benzoylperoxide and N,N-dimethyl-toluidine. This resin was selected because it maintained the antigenicity of the tissue, provided adequate properties for cutting 50 µm thick sections, and it facilitated deacrylizing the sawed sections. Acid-resistant acrylic slides were glued to the blocks using an epoxy resin based two-component adhesive to avoid detachment of the slides during the deacrylation procedure. Samples were stained for alkaline phosphatase, type I collagen, osteonectin, osteopontin, osteocalcin and bone sialoprotein. The EnVision + ™ dextran polymer conjugate two-step visualization system was applied for immunohistochemical detection of these bone matrix proteins. This procedure yielded positive staining for the osteogenic markers in cells and matrix components. The protocol described here facilitates the use of immunohistochemistry on resin embedded sawed sections of bone and provides a convenient and reliable method that can be used routinely for immunohistochemical analysis of hard tissue specimens containing implant materials.  相似文献   

14.
A versatile mineralized bone stain (MIBS) for demonstrating osteoid seams and tetracycline fluorescence simultaneously in thin or thick undecalcified sections has been developed. Bone specimens are fixed in 70% ethanol, but 10% buffered formalin is permissible. Depending upon one's preference, these specimens can be left unstained or be prestained before plastic embedding. Osteoid seams are stained green to jade green, or light to dark purple. Mineralized bone matrix is unstained or green. Osteoblast and osteoclast nuclei are light to dark purple, cytoplasm varies from slightly gray to pink. The identification of osteoid seams by this method agrees closely with identification by in vivo tetracycline uptake using the same section from the same biopsy. The method demonstrates halo volumes, an abnormal, lacunar, low density bone around viable osteocytes in purple. This phenomenon is commonly seen in vitamin D-resistant rickets, fluorosis, renal osteodystrophy, hyperparathyroidism, and is sometimes seen in fluoride treated osteoporotic patients. In osteomalacic bone, most osteoid seams are irregularly stained as indicated by the presence of unmineralized osteoid between mineralized lamellae. The method has been used effectively in staining new bone formation in hydroxyapatite implants and bone grafts. Old, unstained, plastic embedded undecalcified sections are stained as well as fresh sections after removal of the coverslip. This stain also promises to be valuable in the study of different metabolic bone diseases from the point of view of remodeling, histomorphometry, and pathology.  相似文献   

15.
Cells of uninduced Bacillus licheniformis (strain 749) in mid-logarithmic phase have no extensive intracytoplasmic membrane. After induction with cephalosporin C, characteristic organelles that contain tubules and vesicles with single-layered membranes and no visible internal substructure can be seen in thin sections in the periplasm. A magnoconstitutive penicillinase producer (749/C) contains similar structures. It is suggested that they represent a penicillinase secretory apparatus. In the first 15 min after induction, negatively stained preparations of induced 749 show large intracellular vesicles without individual contact with the cell surface. Negatively stained 749/C and fully induced 749 contain invaginations comparable to the structures seen in thin sections. When protoplasts of induced 749 and of 749/C are prepared, vesicles and tubules similar to those seen in thin sections of whole cells are liberated from the cell. Growing protoplasts of induced 749 show massive convolutions of the peripheral membrane, multiple layers of membrane, and characteristic long, slender tubules extending from the protoplast surface. These phenomena are not observed in uninduced 749 except for the production of a relatively small number of tubules. In 749/C, there were fewer convolutions than in induced 749, although tubule production was similar. Multiple layers of membrane were not observed in 749/C. The relation of the penicillinase secretory structures to mesosomes and to secretory structures of other organisms is discussed.  相似文献   

16.
A gallocyanin method for demonstrating cement lines in thin, undecalcified sections of bone has been developed that is compatible with prestaining with osteochrome before plastic embedding. After sectioning at 5 microns on the Jung K heavy duty microtome, the sections are attached to a microslide using Haupt's adhesive mounting medium, placed on a slide warmer at 37 C until completely dry, and deplasticized in xylene at 45 C for 16-24 hr. Sections are stained with 0.15% gallocyanin-5% chrome alum solution for 30 min, followed by staining in buffered Villanueva blood stain for 1-1 1/2 hr, quickly dehydrated, differentiated in equal parts xylene and 100% ethanol, cleared, and mounted in Eukitt's medium. Reversal lines appear as thin, scalloped, blue or purple lines approximately 0.3 micron wide, and arrest lines as thick, homogeneous, straight or evenly curved, dark blue or purple lines approximately 2 microns wide. The method also demonstrates abnormal halo volumes around osteocytes, old and new bone matrix, osteoid seams, and the granular mineralization front at the osteoid-bone interface. It promises to be valuable in the study of age-related bone loss, osteoporosis, and metabolic bone disease.  相似文献   

17.
A gallocyanin method for demonstrating cement lines in thin, undecalcified sections of bone has been developed that is compatible with prestaining with ostcochrome before plastic embedding. After sectioning at 5 pm on the Jung K heavy duty microtome, the sections are attached to a microslide using Haupt's adhesive mounting medium, placed on a slide warmer at 37 C until completely dry, and deplasticized in xylene at 45 C for 16-44 hr. Sections are stained with 0.15% gallocyanin-5% chrome alum solution for 30 min, followed by staining in buffered Villanueva blood stain for 1-1 1/2 hr, quickly dehydrated, differentiated in equal parts xylene and 100% ethanol, cleared, and mounted in Eukitt's medium. Reversal lines appear as thin, scalloped, blue or purple lines approximately 0.3 pm wide, and arrest lines as thick, homogeneous, straight or evenly curved, dark blue or purple lines approximately 2 pm wide. The method also demonstrates abnormal halo volumes around ostcocytes, old and new bone matrix, osteoid seams, and the granular mineralization front at the osteoid-bone interface. It promises to be valuable in the study of age-related bone loss, osteoporosis, and metabolic bone disease.  相似文献   

18.
Purified preparations of tobacco mosaic virus (TMV) and pieces of tomato leaves infected with TMV were embedded in methacrylate or epoxy resin, sectioned, and stained with 1.0% strontium permanganate for electron microscopy. In sections containing purified and intracellular virus, the apparent length of stained particles varied directly with section thickness, indicating stain penetration beyond the surface of the section. Penetration was demonstrated also by stereoscopy. Penetration was less complete when sections were allowed to dry before staining. In most instances the number of identifiable particles per unit area was independent of section thickness but increased when both surfaces of the sections were stained instead of only one surface. Staining was prevented by thin films of methacrylate or epoxy resin placed between the virus section and staining solution. Most results supported the view that electron scattering capacity was enhanced only in particles which intersected the surface of the section exposed to permanganate.  相似文献   

19.
A modification of Bodian's protargol-S technique is done on 7 μm sections of decalcified bone. Light microscopic results are greatly improved when compared to either ground bone sections or decalcified bone stained routinely with hematoxylin and eosin.  相似文献   

20.
Fossil tissues generally require specialized processing. Most thin sectioning techniques yield unstained sections or require unwieldy methods to produce stained sections. I outline here two simple techniques for producing stained, ground, thin sections using readily available Romanowsky-type cytology stains and a urine sediment stain. Results are comparable to hematoxylin and eosin stained specimens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号