首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Tests of two leading brands of membrane filters used for enumerating fecal coliform bacteria showed that Gelman GN-6 filters recovered statistically more colonies of bacteria than did Millipore HAWG 047SO filters from pure cultures incubated at either 35 C (the optimal growth temperature) or 44.5 C (the standard temperature for the fecal coliform test). Standard membrane filter procedures with M-FC broth base were used to enumerate the organisms. Densities of colonies incubated on Gelman filters at 44.5 C averaged 2.3 times greater than those on Millipore filters. Plate counts of the bacteria at both temperatures indicated that incubation at 44.5 C did not inhibit propagation of fecal coliform bacteria. For the pour plates, M-FC broth base plus 1.5% agar was used. This modified medium compared favorably to plate count agar for enumerating Escherichia coli. At 35 and 44.5 C, colony counts on Gelman filters agreed closely with plate counts prepared concurrently, but Millipore counts were consistently lower than plate counts, especially at 44.5 C. Comparative analyses of river water for fecal coliform bacteria by the membrane filter technique gave results comparable to those for the pure cultures.  相似文献   

2.
Reports indicate that the standard membrane filter (MF) technique for recovery of fecal coliform bacteria from chlorinated sewage effluents is less effective than the multiple-tube (or most-probable-number [MPN]) procedure. A modified MF method was developed that requires a preincubation period of 5 h at 35 degrees C followed by 18+/-1 h at 44.5 degrees C. This procedure was evaluated by using both laboratory- and plant-chlorinated primary and secondary effluents. Results obtained by the modified MF method compared favorably with those of the MPN technique for the enumeration of fecal coliforms from chlorinated effluent. Agreement between these two methods was greatest with samples from secondary treatment plants. The average recovery of fecal coliforms by the standard MF procedure was only 14% that of the MPN method, whereas with the modified technique recovery was increased to 68% of the MPN counts. Enhanced recovery resulting from a simple modification in the incubation schedule makes the MF method a valuable adjunct for enumerating fecal coliforms from chlorinated effluents.  相似文献   

3.
Reports indicate that the standard membrane filter (MF) technique for recovery of fecal coliform bacteria from chlorinated sewage effluents is less effective than the multiple-tube (or most-probable-number [MPN]) procedure. A modified MF method was developed that requires a preincubation period of 5 h at 35 degrees C followed by 18+/-1 h at 44.5 degrees C. This procedure was evaluated by using both laboratory- and plant-chlorinated primary and secondary effluents. Results obtained by the modified MF method compared favorably with those of the MPN technique for the enumeration of fecal coliforms from chlorinated effluent. Agreement between these two methods was greatest with samples from secondary treatment plants. The average recovery of fecal coliforms by the standard MF procedure was only 14% that of the MPN method, whereas with the modified technique recovery was increased to 68% of the MPN counts. Enhanced recovery resulting from a simple modification in the incubation schedule makes the MF method a valuable adjunct for enumerating fecal coliforms from chlorinated effluents.  相似文献   

4.
Interest in rapid bacterial detection methods for sanitary indicator bacteria in water prompted a study of the use of [U-14C]mannitol to detect fecal coliforms (FC). A simple method which used m-FC broth, membrane filtration, and two-temperature incubation (35 degrees C for 2 h followed by 44.5 degrees C for 2.5 h) was developed. [U-14C]mannitol was added to the medium, and the temperature was raised to 44.5 degrees C after 2 h at 35 degrees C. 14CO2 was collected as Ba14CO3 and assayed by liquid scintillation spectroscopy. Correlations were examined between FC cell numbers at the start of incubation (standard 24-h FC test) and Ba14CO3 counts per minute after 4.5 h. Results indicated that FC numbers ranging from 1 x 10(1) to 2.1 x 10(5) cells could be detected in 4.5 h. Within-sample reproducibility at all cell concentrations was good, but sample-to-sample reproducibility was variable. Comparisons between m-FC broth and m-FC broth modified by substituting D-mannitol for lactose indicated that the standard m-FC broth was the better test medium. Results from experiments in which dimethyl sulfoxide was used to increase permeability of FC to [U-14C]mannitol indicated no increase in 14CO2 production due to dimethyl sulfoxide. Detection of FC by this method may be useful for rapid estimation of FC levels in freshwater recreational areas, for estimating the quality of potable source water, and potentially for emergency testing of potable water, suspected of contamination due to distribution line breaks or cross-connections.  相似文献   

5.
Interest in rapid bacterial detection methods for sanitary indicator bacteria in water prompted a study of the use of [U-14C]mannitol to detect fecal coliforms (FC). A simple method which used m-FC broth, membrane filtration, and two-temperature incubation (35 degrees C for 2 h followed by 44.5 degrees C for 2.5 h) was developed. [U-14C]mannitol was added to the medium, and the temperature was raised to 44.5 degrees C after 2 h at 35 degrees C. 14CO2 was collected as Ba14CO3 and assayed by liquid scintillation spectroscopy. Correlations were examined between FC cell numbers at the start of incubation (standard 24-h FC test) and Ba14CO3 counts per minute after 4.5 h. Results indicated that FC numbers ranging from 1 x 10(1) to 2.1 x 10(5) cells could be detected in 4.5 h. Within-sample reproducibility at all cell concentrations was good, but sample-to-sample reproducibility was variable. Comparisons between m-FC broth and m-FC broth modified by substituting D-mannitol for lactose indicated that the standard m-FC broth was the better test medium. Results from experiments in which dimethyl sulfoxide was used to increase permeability of FC to [U-14C]mannitol indicated no increase in 14CO2 production due to dimethyl sulfoxide. Detection of FC by this method may be useful for rapid estimation of FC levels in freshwater recreational areas, for estimating the quality of potable source water, and potentially for emergency testing of potable water, suspected of contamination due to distribution line breaks or cross-connections.  相似文献   

6.
Membrane filter method for enumerating Escherichia coli.   总被引:20,自引:19,他引:1       下载免费PDF全文
A membrane filter procedure for enumerating Escherichia coli was developed and evaluated. The method quantifies E. coli within 24 h without requiring subculture and identification of isolates. It incorporates a primary selective-differential medium for gram-negative, lactose-fermenting bacteria; resuscitation of weakened organisms by incubation for 2 h at 35 degrees C before incubation at 44.5 degrees C for 18 to 22 h; and an in situ urease test to differentiate E. coli from other thermotolerant, lactose-positive organisms. The recovery of E. coli from marine, estuarine, and freshwater samples exceeded 90%. Of the presumptively positive colonies, 91% were verified as E. coli. Less than 1% of all of the verified E. coli colonies failed to react typically.  相似文献   

7.
This study compared the performance of a commercial chromogenic medium, CHROMagarECC (CECC), and CECC supplemented with sodium pyruvate (CECCP) with the membrane filtration lauryl sulfate-based medium (mLSA) for enumeration of Escherichia coli and non-E. coli thermotolerant coliforms (KEC). To establish that we could recover the maximum KEC and E. coli population, we compared two incubation temperature regimens, 41 and 44.5 degrees C. Statistical analysis by the Fisher test of data did not demonstrate any statistically significant differences (P = 0.05) in the enumeration of E. coli for the different media (CECC and CECCP) and incubation temperatures. Variance analysis of data performed on KEC counts showed significant differences (P = 0.01) between KEC counts at 41 and 44.5 degrees C on both CECC and CECCP. Analysis of variance demonstrated statistically significant differences (P = 0.05) in the enumeration of total thermotolerant coliforms (TTCs) on CECC and CECCP compared with mLSA. Target colonies were confirmed to be E. coli at a rate of 91.5% and KEC of likely fecal origin at a rate of 77.4% when using CECCP incubated at 41 degrees C. The results of this study showed that CECCP agar incubated at 41 degrees C is efficient for the simultaneous enumeration of E. coli and KEC from river and marine waters.  相似文献   

8.
A Mates  M Schaffer 《Microbios》1986,46(186):45-49
Staphylococcus aureus counts from swimming pool water were determined by the membrane filtration technique. Water samples were passed through a membrane filter and then put on Baird-Parker media. After incubation, the filters were transferred to nutrient agar, and incubated at 37 degrees C, for 3 h. After removal of the filters, the plates were incubated at 60 degrees C for 2 h. An overlay of toluidine blue agar was added and the plates reincubated for 4 h at 37 degrees C. The formation of thermonuclease correlated with the formation of coagulase, and the results indicated that Staphylococcus aureus could be present in swimming pool water without the presence of either coliform or faecal coliform bacteria.  相似文献   

9.
AIMS: The chemical/physical environment of groundwater may contribute to the existence of a subpopulation of small-sized bacteria (filterable bacteria) that fails to be trapped on conventional 0.45 microm-pore-size membrane filters during routine bacteriological water quality analyses. Efforts were directed to determining an efficient recovery method for detection of such cells. METHODS AND RESULTS: Individual groundwater supplies in a rural setting were examined by a double membrane filtration procedure to determine the presence of heterotrophic plate count (HPC) bacteria capable of escaping detection on conventional pore size (0.45 microm) membrane filters but retained on 0.22 microm-pore-size filters. Since optimum cultural conditions for recovery of filterable bacteria are not well defined, initial efforts focused on evaluation of various media (R2A, m-HPC and NWRI) and incubation temperatures (15, 20, 28 and 35 degrees C) for specific recovery of filterable bacteria. Maximum recovery of small-sized HPC bacteria occurred on low-nutrient concentration R2A agar incubated for 7 d at 28 degrees C. Similarly, identical cultural conditions gave enhanced detection of the general HPC population on 0.45 microm-pore-size filters. A 17-month survey of 10 well water supplies conducted with the cultural conditions described above resulted in detection of filterable bacteria (ranging in density from 9 to 175 cfu ml-1) in six of the groundwater sources. The proportion of filterable bacteria in any single sample never exceeded 10% of the total HPC population. A majority of the colonies appearing on the 0.22 microm membrane filters was pigmented (50-90%), whereas the proportion of colonies demonstrating pigmentation on the larger porosity filters failed to exceed 50% for any of the samples (19-49%). CONCLUSION: A reliable recovery method was developed for the detection of filterable bacteria from groundwater. During a subsequent survey study using this procedure, filterable bacteria were detected in a majority of the groundwater supplies examined; however, the density of filterable bacteria in any single sample never exceeded 10% of the total HPC population. Identification of randomly selected isolates obtained on the 0.22 microm filters indicated that some of these filterable bacteria have been implicated as opportunistic pathogens. SIGNIFICANCE AND IMPACT OF THE STUDY: We have determined the presence of small-sized HPC bacteria in ground water that may go undetected when using standard porosity membrane filters for water quality analyses. Further study is needed to assess the significance and possible health risk associated with presence of filterable bacteria in drinking water supplies from groundwater sources.  相似文献   

10.
Loss of plasmids during enrichment for Escherichia coli.   总被引:9,自引:5,他引:4       下载免费PDF全文
Enrichment with sodium lauryl sulfate and incubation at 44.5 degrees C resulted in a loss of plasmids and decreased efficiency in the recovery of pathogenic. Escherichia coli strains from foods.  相似文献   

11.
The physiological basis of the Eijkman elevated-temperature test for differentiating fecal from nonfecal coliforms was investigated. Manometric studies indicated that the inhibitory effect upon growth and metabolism in a nonfecal coliform at 44.5 degrees C involved cellular components common to both aerobic and fermentative metabolism of lactose. Radioactive substrate incorporation experiments implicated cell membrane function as a principal focus for temperature sensitivity at 44.5 degrees C. A temperature increase from 35 to 44.5 degrees C drastically reduced the rates of [14C]glucose uptake in nonfecal coliforms, whereas those of fecal coliforms were essentially unchanged. In addition, relatively low levels of nonfecal coliform beta-galactosidase activity coupled with thermal inactivation of this enzyme at a comparatively low temperature may also inhibit growth and metabolism of nonfecal coliforms at the elevated temperature.  相似文献   

12.
Fecal coliform elevated-temperature test: a physiological basis.   总被引:2,自引:2,他引:0       下载免费PDF全文
The physiological basis of the Eijkman elevated-temperature test for differentiating fecal from nonfecal coliforms was investigated. Manometric studies indicated that the inhibitory effect upon growth and metabolism in a nonfecal coliform at 44.5 degrees C involved cellular components common to both aerobic and fermentative metabolism of lactose. Radioactive substrate incorporation experiments implicated cell membrane function as a principal focus for temperature sensitivity at 44.5 degrees C. A temperature increase from 35 to 44.5 degrees C drastically reduced the rates of [14C]glucose uptake in nonfecal coliforms, whereas those of fecal coliforms were essentially unchanged. In addition, relatively low levels of nonfecal coliform beta-galactosidase activity coupled with thermal inactivation of this enzyme at a comparatively low temperature may also inhibit growth and metabolism of nonfecal coliforms at the elevated temperature.  相似文献   

13.
A new medium for the enumeration and subculture of bacteria from potable water   总被引:37,自引:0,他引:37  
Plate count agar is presently the recommended medium for the standard bacterial plate count (35 degrees C, 48-h incubation) of water and wastewater. However, plate count agar does not permit the growth of many bacteria that may be present in treated potable water supplies. A new medium was developed for use in heterotrophic plate count analyses and for subculture of bacteria isolated from potable water samples. The new medium, designated R2A, contains 0.5 g of yeast extract, 0.5 g of Difco Proteose Peptone no. 3 (Difco Laboratories), 0.5 g of Casamino Acids (Difco), 0.5 g of glucose, 0.5 g of soluble starch, 0.3 g of K2HPO4, 0.05 g of MgSO4 X 7H2O, 0.3 g of sodium pyruvate, and 15 g of agar per liter of laboratory quality water. Adjust the pH to 7.2 with crystalline K2HPO4 or KH2PO4 and sterilize at 121 degrees C for 15 min. Results from parallel studies with spread, membrane filter, and pour plate procedures showed that R2A medium yielded significantly higher bacterial counts than did plate count agar. Studies of the effect of incubation temperature showed that the magnitude of the count was inversely proportional to the incubation temperature. Longer incubation time, up to 14 days, yielded higher counts and increased detection of pigmented bacteria. Maximal bacterial counts were obtained after incubation at 20 degrees C for 14 days. As a tool to monitor heterotrophic bacterial populations in water treatment processes and in treated distribution water, R2A spread or membrane filter plates incubated at 28 degrees C for 5 to 7 days is recommended.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
Plate count agar is presently the recommended medium for the standard bacterial plate count (35 degrees C, 48-h incubation) of water and wastewater. However, plate count agar does not permit the growth of many bacteria that may be present in treated potable water supplies. A new medium was developed for use in heterotrophic plate count analyses and for subculture of bacteria isolated from potable water samples. The new medium, designated R2A, contains 0.5 g of yeast extract, 0.5 g of Difco Proteose Peptone no. 3 (Difco Laboratories), 0.5 g of Casamino Acids (Difco), 0.5 g of glucose, 0.5 g of soluble starch, 0.3 g of K2HPO4, 0.05 g of MgSO4 X 7H2O, 0.3 g of sodium pyruvate, and 15 g of agar per liter of laboratory quality water. Adjust the pH to 7.2 with crystalline K2HPO4 or KH2PO4 and sterilize at 121 degrees C for 15 min. Results from parallel studies with spread, membrane filter, and pour plate procedures showed that R2A medium yielded significantly higher bacterial counts than did plate count agar. Studies of the effect of incubation temperature showed that the magnitude of the count was inversely proportional to the incubation temperature. Longer incubation time, up to 14 days, yielded higher counts and increased detection of pigmented bacteria. Maximal bacterial counts were obtained after incubation at 20 degrees C for 14 days. As a tool to monitor heterotrophic bacterial populations in water treatment processes and in treated distribution water, R2A spread or membrane filter plates incubated at 28 degrees C for 5 to 7 days is recommended.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
Four combinations of media for membrane filtration (MF) and one for Most Probable Number (MPN) estimation were evaluated for their ability to enumerate faecal streptococci from five types of waters under winter conditions, using various regimes of temperature and incubation. A total of 5910 isolates was identified and the data used to recalculate the total populations estimated by each method. From this study the most notable observation was that those media incubated at 44.5 °C to enhance their selectivity were the least sensitive. The sensitivity of the MPN procedure utilizing azide dextrose and ethyl violet azide broths incubated at 35 °C for 48 h was equal to that of the most sensitive membrane filtration procedure.  相似文献   

16.
Total coliform (TC), fecal coliform (FC), and fecal streptococcus (FS) survival characteristics, under natural conditions at 0 degrees C in an ice-covered river, were examined during February and March 1975. The membrane filter (MF) technique was used throughout the study, and the multiple-tube (MPN) method was used in parallel on three preselected days for comparative recovery of these bacteria. Survival was studied at seven sample stations downstream from all domestic pollution sources in a 317-km reach of the river having 7.1 days mean flow time (range of 6.0 to 9.1 days). The mean indicator bacteria densities decreased continuously at successive stations in this reach and, after adjustment for dilution, the most rapid die-off was found to occur during the first 1.9 days, followed by a slower decrease. After 7.1 days, the relative survival was TC less than FC less than FS, with 8.4%, 15.7%, and 32.8% of the initial populations remaining viable, respectively. These rates are higher than previously reported and suggest that the highest survival rates for these bacteria in receiving streams can be expected at 0 degree C under ice cover. Additionally, the FC-FS ratio was greater than 5 at all stations, indicating that this ratio may be useable for determining the source of fecal pollution in receiving streams for greater than 7 days flow time at low water temperatures. The MPN and MF methods gave comparable results for the TC and FS at all seven sample stations, with both the direct and verified MF counts within the 95% confidence limits of the respective MPNs in most samples, but generally lower than the MPN index. Although FC recovery on membrane filters was comparable results at stations near the pollution source. However, the results became more comparable with increasing flow time. The results of this study indicate that heat shock is a major factor in suppression of the FC counts on the membrane filters at 44.5 degree C. Heat shock may be minimized by extended incubation at 35 degrees C before exposure to the higher temperature.  相似文献   

17.
AIMS: To develop improved methods for the detection of Escherichia coli O157 from water and sediments. METHODS AND RESULTS: The effects of different broth enrichment media (unsupplemented tryptic soya broth, tryptic soya broth with antibiotics, and gram-negative broth), incubation durations (5 and 24 hrs), incubation temperatures (37 and 44.5 degrees C) and the use of immunomagnetic separation (IMS) on the sensitivity of E. coli O157 detection were evaluated on artificially and naturally-contaminated water and sediment samples. The sensitivity of recovery of E. coli O157 from samples was dependent upon the media composition, temperature duration of incubation and the use of IMS. CONCLUSION: Use of high temperature (44.5 degrees C) incubation for 24 hrs in unsupplemented tryptic soya broth and the use of IMS improved the sensitivity of E. coli O157 culture from water and sediment samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The methods described can be used to increase the sensitivity of E. coli O157 detection from water and sediments.  相似文献   

18.
A membrane filtration technique has been developed for the enumeration of Bacteroides fragilis group (BFG) organisms from sewage and natural waters. The method uses the agar medium of Wilkins and Chalgren supplemented with gentamicin, penicillin, aesculin and ferric ammonium citrate. Membrane filters with 0.22 micron pores were significantly more efficient than those with 0.45 micron pores in the isolation of BFG. A preliminary incubation period of 4 h at 30 degrees C prior to 44 h at 37 degrees C yielded significantly higher numbers of BFG than direct incubation at 37 degrees C for 48 h.  相似文献   

19.
Several protocols for isolation of mycobacteria from water exist, but there is no established standard method. This study compared methods of processing potable water samples for the isolation of Mycobacterium avium and Mycobacterium intracellulare using spiked sterilized water and tap water decontaminated using 0.005% cetylpyridinium chloride (CPC). Samples were concentrated by centrifugation or filtration and inoculated onto Middlebrook 7H10 and 7H11 plates and Lowenstein-Jensen slants and into mycobacterial growth indicator tubes with or without polymyxin, azlocillin, nalidixic acid, trimethoprim, and amphotericin B. The solid media were incubated at 32 degrees C, at 35 degrees C, and at 35 degrees C with CO(2) and read weekly. The results suggest that filtration of water for the isolation of mycobacteria is a more sensitive method for concentration than centrifugation. The addition of sodium thiosulfate may not be necessary and may reduce the yield. Middlebrook M7H10 and 7H11 were equally sensitive culture media. CPC decontamination, while effective for reducing growth of contaminants, also significantly reduces mycobacterial numbers. There was no difference at 3 weeks between the different incubation temperatures.  相似文献   

20.
To the problem of Campylobacter jejuni detectability in water   总被引:1,自引:0,他引:1  
In a series of model experiments two isolation procedures for the detection of water-borne Campylobacter jejuni were compared: a standard culture in thioglycolate broth enriched with 7% defibrinated sheep blood and supplement C and a modified membrane filtration method in which the filter (porosity 0.45 microns) plated on campylobacter agar surface was removed after the first 24 hours of incubation and the plate further incubated for 48 hours. The recovery rates by the thioglycolate broth method were markedly less pronounced than those obtained by the modification of membrane filtration technique, especially in the case of water rich in organics. The best isolation parameters were achieved with water samples of at least 10 ml in volume.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号