1.
AimTo determine the setup reproducibility in the radiation treatment of Head and Neck (HN) patients using open face head and shoulder masks (OHSM) with customized headrest (CHR) versus standard closed head and shoulder masks (CHSM) and to determine the patient’s level of comfort and satisfaction for both masks.MethodsForty patients were prospectively randomized into two groups using simple random sampling. Group 1 was assigned with CHSMs, immobilized with a standard HR (SHR) while Group 2 was assigned with OHSMs, and immobilized with CHR. Cone beam computed tomography (CBCT) was taken the first 3 days, followed by weekly CBCT (prior treatment) with results registered to the planning CT to determine translational and rotational inter-fraction shifts and to verify accuracy. Mean (M) and standard deviation (SD) of the systematic and random setup errors of the 2 arms in the translational and rotational directions were analyzed, using Independent t-test and Mann–Whitney U test. Patient comfort was measured using a Likert questionnaire.ResultsThe vertical, lateral, longitudinal and Z/roll rotational shifts were not significantly different between the two masks. X/yaw and Y/pitch rotational shifts were significantly greater in Group 2 versus Group 1, for both systematic (p = 0.009 and 0.046, respectively) and random settings (p = 0.016 and 0.020) but still within three degrees. Patients reported higher neck and shoulder comfort (p = 0.020) and overall satisfaction (p = 0.026) using the OHSM with the CHR versus the CHSM with the SHR during CT simulation.ConclusionOpen masks provide comparable yet comfortable immobilization to closed masks for HN radiotherapy.  相似文献   

2.
PurposeWhen using volumetric modulated arc therapy (VMAT) for head and neck cancer, setup errors regarding the shoulders can create loss of target coverage or increased organ-at-risk doses. This study created variations of realistic shoulder deformations to understand the associated VMAT dosimetric effects and investigated water-equivalent thickness (WET) differences using in-house software.MethodsTen patients with head and neck cancer with lower neck involvement were retrospectively and randomly enrolled. Their retrospective analysis comprised treatment planning using RayStation 5.0 (RaySearch Laboratories, Stockholm, Sweden), shoulder deformation of 5–15 mm in three-dimensional axes using the ImSimQA package (Oncology Systems Limited, Shrewsbury, Shropshire, UK), and evaluation of the clinical impact of the dose distribution after recalculating the dose distribution using computed tomography images of deformed shoulders and deforming the dose distribution. Additionally, our in-house software program was used to measure WET differences for shoulder deformation.ResultsWET differences were greater in the superoinferior (SI) direction than in the other directions (the WET difference was >20 mm for 15-mm SI deformation). D99%, D98%, and D95% for all clinical target volumes were within 3%. Local dose differences of more than ±10% were found for normal tissues at the level of the shoulder for 15-mm movement in the SI direction.ConclusionsShoulder deformation of >6 mm could cause large dose variations delivered to the targeted tissue at the level of the shoulder. Thus, to ensure delivery of appropriate treatment coverage to the targeted tissue, shoulder deformation should be taken into consideration during the planning stage.  相似文献   

3.
PurposeTo compare the planning target volume (PTV) margins needed for prostate patients who have used hydrogel spacer or rectal balloon during proton treatments.MethodTotal of 190 prostate patients treated with proton therapy during 2017 were selected for this study. Of these patients, 96 had hydrogel spacer injection and 94 patients had only rectal balloons insertion. All patients had implanted gold markers inside the prostate for daily target alignment. Post-treatment radigraphs were obtained to evaluate prostate intrafraction motion. The systematic and random components of patient setup residual error and prostate intrafraction motion error were obtained. PTV margins were calculated using the van Herk formula for both patient groups.ResultsFor setup residual error, the mean values in the superior-inferior (SI) direction and the variances in the left–right (LR) direction were statistically different between the two groups. For intrafraction motion, there were significant differences of the mean values in the SI direction and of the variances in both LR and anterior-posterior (AP) directions. The population PTV margins for hydrogel spacer group were 2.6 mm, 3.3 mm, and 1.6 mm in LR, SI, AP directions, respectively. For the rectal balloon group, the PTV margins were 2.1 mm, 3.1 mm, and 2.0 mm in LR, SI, AP directions, respectively.ConclusionStatistically significant differences were observed in the patient setup and prostate intrafraction motion errors of the two patient groups. However, under the current protocol of bladder preparation and daily marker-based x-ray image-guidance, population PTV margins were comparable between the two patient groups.  相似文献   

4.
PurposeTo evaluate inter-fraction tumor localization errors (TE) in the RapidArc® treatment of pelvic cancers based on CBCT. Appropriate CTV-to PTV margins in a non-IGRT scenario have been proposed.MethodsData of 928 patients with prostate, gynecological, and rectum/anal canal cancers were retrospectively analyzed to determine systematic and random localization errors. Two protocols were used: daily online IGRT (d-IGRT) and weekly IGRT. The latter consisted in acquiring a CBCT for the first 3 fractions and subsequently once a week. TE for patients who underwent d-IGRT protocol were calculated using either all CBCTs or the first 3.ResultsThe systematic (and random) TE in the AP, LL, and SI direction were: for prostate bed 2.7(3.2), 2.3(2.8) and 1.9(2.2) mm; for prostate 4.2(3.1), 2.9(2.8) and 2.3(2.2) mm; for gynecological 3.0(3.6), 2.4(2.7) and 2.3(2.5) mm; for rectum 2.8(2.8), 2.4(2.8) and 2.3(2.5) mm; for anal canal 3.1(3.3), 2.1(2.5) and 2.2(2.7) mm. CTV-to-PTV margins determined from all CBCTs were 14 mm in the AP, 10 mm in the LL and 9–9.5 mm in the SI directions for the prostate and the gynecological groups and 9.5–10.5 mm in AP, 9 mm in LL and 8–10 mm in the SI direction for the prostate bed and the rectum/anal canal groups. If assessed on the basis of the first 3 CBCTs, the calculated CTV-to-PTV margins were slightly larger.Conclusionswithout IGRT, large CTV-to-PTV margins up to 15 mm are required to account for inter-fraction tumor localization errors. Daily IGRT should be used for all hypo-fractionated treatments to reduce margins and avoid increased toxicity to critical organs.  相似文献   

5.
PurposeAccurate localization is crucial in delivering safe and effective stereotactic body radiation therapy (SBRT). The aim of this study was to analyse the accuracy of image-guidance using the cone-beam computed tomography (CBCT) of the VERO system in 57 patients treated for lung SBRT and to calculate the treatment margins.Materials and methodsThe internal target volume (ITV) was obtained by contouring the tumor on maximum and mean intensity projection CT images reconstructed from a respiration correlated 4D-CT. Translational and rotational tumor localization errors were identified by comparing the manual registration of the ITV to the motion-blurred tumor on the CBCT and they were corrected by means of the robotic couch and the ring rotation. A verification CBCT was acquired after correction in order to evaluate residual errors.ResultsThe mean 3D vector at initial set-up was 6.6 ± 2.3 mm, which was significantly reduced to 1.6 ± 0.8 mm after 6D automatic correction. 94% of the rotational errors were within 3°. The PTV margins used to compensate for residual tumor localization errors were 3.1, 3.5 and 3.3 mm in the LR, SI and AP directions, respectively.ConclusionsOn-line image guidance with the ITV–CBCT matching technique and automatic 6D correction of the VERO system allowed a very accurate tumor localization in lung SBRT.  相似文献   

6.
Purpose/objectiveTo evaluate intra-fraction target shift during automated mono-isocentric linac-based stereotactic radiosurgery with open-face mask system and optical real-time tracking.Materials/methodsNinety-five patients were treated using automated linac-based stereotactic radiosurgery in 1–5 fractions with single isocenter for a total of 195 fractions. During treatment, patient positioning was tracked real-time with optical surface guidance and immobilized with a rigid open-face mask. Patients were re-positioned if optical surface guidance error exceeded 1 mm magnitude or 1°. Translational and rotational intra-fractional changes were determined by post-treatment CBCT matched to the planning CT. Target specific error was calculated by translation and rotation matrices applied to isocenter and target spatial coordinates.ResultsFor 132 fractions with isocenter within a single target, the median shift magnitude was 0.40 mm with a maximum shift of 1.17 mm. A total of 398 targets treated for plans having multiple or single targets that lied outside isocenter, resulted in a median shift magnitude of 0.46 mm, with median translational shifts of 0.20 mm and 0.20° rotational shifts. A 1 mm PTV margin was insufficient in 18% of targets at a distance greater than 6 cm away from isocenter, but sufficient for 96% of targets within 6 cm.ConclusionsThe findings of this study support 1 mm PTV expansion due to intra-fraction motion to ensure target coverage for plans with isocenter placement less than 6 cm away from the targets.  相似文献   

7.
PurposeElectronic portal imaging detector (EPID)-based patient positioning verification is an important component of safe radiotherapy treatment delivery. In computer simulation studies, learning-based approaches have proven to be superior to conventional gamma analysis in the detection of positioning errors. To approximate a clinical scenario, the detectability of positioning errors via EPID measurements was assessed using radiomics analysis for patients with thyroid-associated ophthalmopathy.MethodsTreatment plans of 40 patients with thyroid-associated ophthalmopathy were delivered to a solid anthropomorphic head phantom. To simulate positioning errors, combinations of 0-, 2-, and 4-mm translation errors in the left–right (LR), superior-inferior (SI), and anterior-posterior (AP) directions were introduced to the phantom. The positioning errors-induced dose differences between measured portal dose images were used to predict the magnitude and direction of positioning errors. The detectability of positioning errors was assessed via radiomics analysis of the dose differences. Three classification models—support vector machine (SVM), k-nearest neighbors (KNN), and XGBoost—were used for the detection of positioning errors (positioning errors larger or smaller than 3 mm in an arbitrary direction) and direction classification (positioning errors larger or smaller than 3 mm in a specific direction). The receiver operating characteristic curve and the area under the ROC curve (AUC) were used to evaluate the performance of classification models.ResultsFor the detection of positioning errors, the AUC values of SVM, KNN, and XGBoost models were all above 0.90. For LR, SI, and AP direction classification, the highest AUC values were 0.76, 0.91, and 0.80, respectively.ConclusionsCombined radiomics and machine learning approaches are capable of detecting the magnitude and direction of positioning errors from EPID measurements. This study is a further step toward machine learning-based positioning error detection during treatment delivery with EPID measurements.  相似文献   

8.
PurposeTo evaluate the accuracy of an intra-modality trans-abdominal ultrasound (TA-US) device against soft-tissue based Cone-Beam Computed tomography (CBCT) registration for prostate and post-prostatectomy pre-treatment positioning.MethodsThe differences between CBCT and US shifts were calculated on 25 prostate cancer patients (cohort A) and 11 post-prostatectomy patients (cohort B), resulting in 284 and 106 paired shifts for cohorts A and B, respectively. As a second step, a corrective method was applied to the US registration results to decrease the systematic shifts observed between TA-US and CBCT results. This method consisted of subtracting the mean difference obtained between US and CBCT registration results during the first 3 sessions from the US registration results of the subsequent sessions. Inter-operator registration variability (IOV) was also investigated for both modalities.ResultsAfter initial review, about 20% of the US images were excluded because of insufficient quality. The average differences between US and CBCT were: 2.8 ± 4.1 mm, −0.9 ± 4.2 mm, 0.4 ± 3.4 mm for cohort A and 1.3 ± 5.0 mm, −2.3 ± 4.6 mm, 0.5 ± 2.9 mm for cohort B, in the anterior-posterior (AP), superior-inferior (SI) and lateral (LR) directions, respectively. After applying the corrective method, only the differences in the AP direction remained significant (p < 0.05). The IOV values were between 0.6–2.0 mm and 2.1–3.5 mm for the CBCT and TA-US modalities, respectively.ConclusionsBased on the obtained results and on the image quality, the TA-US imaging modality is not safely interchangeable with CBCT for pre-treatment repositioning. Treatment margins adaptation based on the correction of the systematic shifts should be considered.  相似文献   

9.
Movement of the target object during cone-beam computed tomography (CBCT) leads to motion blurring artifacts. The accuracy of manual image matching in image-guided radiotherapy depends on the image quality. We aimed to assess the accuracy of target position localization using free-breathing CBCT during stereotactic lung radiotherapy. The Vero4DRT linear accelerator device was used for the examinations. Reference point discrepancies between the MV X-ray beam and the CBCT system were calculated using a phantom device with a centrally mounted steel ball. The precision of manual image matching between the CBCT and the averaged intensity (AI) images restructured from four-dimensional CT (4DCT) was estimated with a respiratory motion phantom, as determined in evaluations by five independent operators. Reference point discrepancies between the MV X-ray beam and the CBCT image-guidance systems, categorized as left-right (LR), anterior-posterior (AP), and superior-inferior (SI), were 0.33 ± 0.09, 0.16 ± 0.07, and 0.05 ± 0.04 mm, respectively. The LR, AP, and SI values for residual errors from manual image matching were -0.03 ± 0.22, 0.07 ± 0.25, and -0.79 ± 0.68 mm, respectively. The accuracy of target position localization using the Vero4DRT system in our center was 1.07 ± 1.23 mm (2 SD). This study experimentally demonstrated the sufficient level of geometric accuracy using the free-breathing CBCT and the image-guidance system mounted on the Vero4DRT. However, the inter-observer variation and systematic localization error of image matching substantially affected the overall geometric accuracy. Therefore, when using the free-breathing CBCT images, careful consideration of image matching is especially important.  相似文献   

10.
PurposeImage-guided radiation therapy could benefit from implementing adaptive radiation therapy (ART) techniques. A cycle-generative adversarial network (cycle-GAN)-based cone-beam computed tomography (CBCT)-to-synthetic CT (sCT) conversion algorithm was evaluated regarding image quality, image segmentation and dosimetric accuracy for head and neck (H&N), thoracic and pelvic body regions.MethodsUsing a cycle-GAN, three body site-specific models were priorly trained with independent paired CT and CBCT datasets of a kV imaging system (XVI, Elekta). sCT were generated based on first-fraction CBCT for 15 patients of each body region. Mean errors (ME) and mean absolute errors (MAE) were analyzed for the sCT. On the sCT, manually delineated structures were compared to deformed structures from the planning CT (pCT) and evaluated with standard segmentation metrics. Treatment plans were recalculated on sCT. A comparison of clinically relevant dose-volume parameters (D98, D50 and D2 of the target volume) and 3D-gamma (3%/3mm) analysis were performed.ResultsThe mean ME and MAE were 1.4, 29.6, 5.4 Hounsfield units (HU) and 77.2, 94.2, 41.8 HU for H&N, thoracic and pelvic region, respectively. Dice similarity coefficients varied between 66.7 ± 8.3% (seminal vesicles) and 94.9 ± 2.0% (lungs). Maximum mean surface distances were 6.3 mm (heart), followed by 3.5 mm (brainstem). The mean dosimetric differences of the target volumes did not exceed 1.7%. Mean 3D gamma pass rates greater than 97.8% were achieved in all cases.ConclusionsThe presented method generates sCT images with a quality close to pCT and yielded clinically acceptable dosimetric deviations. Thus, an important prerequisite towards clinical implementation of CBCT-based ART is fulfilled.  相似文献   

11.
The link between supporting leg stability and individual trunk strategies used during spontaneous whole-body rotations was studied according to visual and kinesthetic imagery styles for classical dancers and untrained female participants. Shoulders–hip angles in the horizontal plane and supporting leg (SL) displacements were analyzed with three-dimensional kinematic at the beginning and end of the four turns, identified according to their SL (left vs. right) and turn direction (clockwise, CW vs. counterclockwise, CCW). To begin a turn in CCW on left SL, all the participants turned shoulders before hips (?25° angle), p < 0.01. Untrained participants yielded the reverse (+30° angle) in CW – their non-preferred turn - whereas dancers maintained their trunk en bloc. In the turn slow down, in their preferred direction all the participants adopted en bloc behavior to avoid imbalance. Dancers kept this pattern in CCW but untrained participants separated shoulders and hips, p < 0.01; on left SL (+20° angle) hips finished before shoulders and on right SL (?25° angle), shoulders finished before hips. Both mental imagery styles and spatial context link reduction of shoulder–hip angle and stability of SL. Daily expertise, not only dance training, facilitates the en bloc shoulder–hip coordination to maintain equilibrium.  相似文献   

12.
PurposeTo define optimal planning target volume (PTV) margins for intensity modulated radiotherapy (IMRT) ± knee-heel support (KHS) in patients treated with adjuvant radiotherapy.MethodsComputed tomography (CT) scans ± KHS of 10 patients were taken before and at 3rd and 5th week of treatment, fused and compared with initial IMRT plans.ResultsA PTV margin of 15 mm in anteroposterior (AP) and superoinferior (SI) directions and 5 mm in lateral directions were found to be adequate without any difference between ± KHS except for the SI shifts in CTV-primary at the 3rd week. Five mm margin for iliac CTV was found to be inadequate in 10–20% of patients in SI directions however when 7 mm margin was given for iliac PTV, it was found to be adequate. For presacral CTV, it was found that the most striking shift of the target volume was in the direction of AP. KHS caused significantly less volume of rectum and bladder in the treated volume.ConclusionsPTV margin of 15 mm in SI and AP, and 5 mm in lateral directions for CTV-primary were found to be adequate. A minimum of 7 mm PTV margin should be given to iliac CTV. The remarkable shifting in presacral CTV was believed to be due to the unforeseen hip malposition of obese patients. The KHS seems not to provide additional beneficial effect in decreasing the shifts both in CTV-primary and lymphatic, however it may have a beneficial effect of decreasing the OAR volume in PTV margins.  相似文献   

13.
AimThe aim was to find an optimal setup image matching position and minimal setup margins to maximally spare the organs at risk in breast radiotherapy.BackgroundRadiotherapy of breast cancer is a routine task but has many challenges. We investigated residual position errors in whole breast radiotherapy when orthogonal setup images were matched to different bony landmarks.Materials and methodsA total of 1111 orthogonal setup image pairs and tangential field images were analyzed retrospectively for 50 consecutive patients. Residual errors in the treatment field images were determined by matching the orthogonal setup images to the vertebrae, sternum, ribs and their compromises. The most important region was the chest wall as it is crucial for the dose delivered to the heart and the ipsilateral lung. Inter-observer variation in online image matching was investigated.ResultsThe best general image matching position was the compromise of the vertebrae, ribs and sternum, while the worst position was the vertebrae alone (p  0.03). The setup margins required for the chest wall varied from 4.3 mm to 5.5 mm in the lung direction while in the superior–inferior (SI) direction the margins varied from 5.1 mm to 7.6 mm. The inter-observer variation increased the minimal margins by approximately 1 mm. The margin of the lymph node areas should be at least 4.8 mm.ConclusionsSetup margins can be reduced by proper selection of a matching position for the orthogonal setup images. To retain the minimal margins sufficient, systematic error of the chest wall should not exceed 4 mm in the tangential field image.  相似文献   

14.
PurposeTo commission and assess the performance of AlignRT InBore™, a Halcyon™ and Ethos™-dedicated Surface Guided Radiation Therapy (SGRT) platform which combines ceiling-mounted cameras for patient setup and bore-mounted cameras for in-bore tracking.MethodsTo check the potential impact of InBore™ cameras on dose delivery, 16 SRS, H&N, breast and pelvis patients’ quality assurance (QA) treatment plans were measured with/without AlignRT InBore™ and using ArcCHECK® and SRS MapCHECK®. Impact on image quality was determined using Catphan® 540 phantom and considering all available MV and CBCT protocols (head, breast, chest and pelvis). The stability, accuracy and overall performance of AlignRT InBore™ was assessed using an MV Cube and anthropomorphic phantoms.ResultsComparison of 2D dose distributions with/without AlignRT InBore™ showed no impact on treatment delivery for all 16 QA checks (p-value > 0.25). 2D and CBCT images showed no artefacts or change in the contrast-to-noise ratio, resolution and noise values measured with Catphan® 540. Anti-collision sensors were unaffected by the bore-mounted cameras. Additionally, AlignRT InBore™ cameras allowed for motion detection with sub-0.5 mm accuracy and sub-0.4 mm stability with surface coverage of >50 × 60 × 35 cc. Accurate transition (sub-0.3 mm) from virtual to treatment isocentres was achieved. Finally, Halcyon™ rotations during CBCT and beam delivery resulted in limited camera vibrations with translation uncertainty <0.5 mm in left-right and anterior-posterior directions and <0.1 mm in head-feet direction.ConclusionAlignRT InBore™ provides SGRT setup and intrafraction monitoring capabilities with a performance comparable to standard SGRT solutions while having no adverse effect on Halcyon™.  相似文献   

15.
IntroductionThe aim of this study was to evaluate three-dimensional (3D) set-up errors and propose optimum margins for planning target volume (PTV) coverage in head and neck radiotherapy.MethodsThirty-five patients were included in the study. The total number of portal images studied was 632. Population systematic (Σ) and random (σ) errors for the patients with head and neck cancer were evaluated based on the portal images in the caudocranial longitudinal (CC) and left-right lateral (LR) direction measured in the anterior-posterior (AP) field, as well as from the images in the caudocranial longitudinal (CC) and dorsoventral lateral (DV) direction measured in the lateral (LAT) field. The values for the clinical-to-planning target volume (CTV-PTV) margins were calculated using ICRU Report 62 recommendations, along with Stroom's and van Herk's formulae.ResultsThe standard deviations of systematic set-up errors (Σ) ranged from 1.51 to 1.93 mm while the standard deviations of random set-up (σ) errors fell in between 1.77 and 1.86 mm. The mean 3D vector length of displacement was 2.66 mm. PTV margins calculated according to ICRU, Stroom's and van Herk's models were comprised between 1.95 and 6.16 mm in the three acquisition directions.Discussion and conclusionsBased on our results we can conclude that a 6-mm extension of CTV to PTV margin, as the lower limit, is enough to ensure that 90% of the patients treated for head and neck cancer will receive a minimum cumulative CTV dose greater than or equal to 95% of the prescribed dose.  相似文献   

16.
PurposeThis study proposed a synchronous measurement method for patient-specific dosimetry using two three-dimensional dose verification systems with delivery errors.MethodsTwenty hypofractionated radiotherapy treatment plans for patients with lung cancer were retrospectively reviewed. Monitor unit (MU) changes, leaf in-position errors, and angles of deviation of the collimator were intentionally introduced to investigate the detection sensitivity of the EDose + EPID (EE) and Dolphin + Compass (DC) systems.ResultsBoth systems accurately detected the MU modifications and had a similar ability to detect leaf in-position errors. The detection of multi-leaf collimator (MLC) errors was difficult for the whole body using different gamma criteria. When the introduced MLC error was 1.0 mm, the numbers of errors detected in the clinical target volume (CTV) by the EE system were 20, 20, and 20 and the numbers of errors detected by the DC system were 18, 19, and 20, at 3%/2 mm, 2%/2 mm, and 1%/1 mm, respectively. The average dose deviation of all DVH parameters exceeded 3%. The gamma and DVH evaluation results remained unchanged for the DC system when different collimator angle errors were introduced. The number of errors detected by the EE system was <11 for each anatomical structure for all gamma criteria. The mean dose deviation of the CTV was not distinguished.ConclusionsThis synchronous measurement approach can effectively eliminate the influence of random errors during treatment. The EE and DC systems reconstruct the three-dimensional dose distribution accurately and are convenient and reliable for dose verification.  相似文献   

17.
Background and purposeTo compare the accuracy of the Block Matching deformable registration (DIR) against rigid image registration (RIR) for head-and-neck multi-modal images CT to cone-beam CT (CBCT) registration.Material and methodsPlanning-CT and weekly CBCT of 10 patients were used for this study. Several volumes, including medullary canal (MC), thyroid cartilage (TC), hyoid bone (HB) and submandibular gland (SMG) were transposed from CT to CBCT images using either DIR or RIR. Transposed volumes were compared with the manual delineation of these volumes on every CBCT. The parameters of similarity used for analysis were: Dice Similarity Index (DSI), 95%-Hausdorff Distance (95%-HD) and difference of volumes (cc).ResultsWith DIR, the major mean difference of volumes was −1.4 cc for MC, revealing limited under-segmentation. DIR limited variability of DSI and 95%-HD. It significantly improved DSI for TC and HB and 95%-HD for all structures but SMG. With DIR, mean 95%-HD (mm) was 3.01 ± 0.80, 5.33 ± 2.51, 4.99 ± 1.69, 3.07 ± 1.31 for MC, TC, HB and SMG, respectively. With RIR, it was 3.92 ± 1.86, 6.94 ± 3.98, 6.44 ± 3.37 and 3.41 ± 2.25, respectively.ConclusionBlock Matching is a valid algorithm for deformable multi-modal CT to CBCT registration. Values of 95%-HD are useful for ongoing development of its application to the cumulative dose calculation.  相似文献   

18.
Background and purposeTo evaluate the impact of deformation magnitude and image modality on deformable-image-registration (DIR) accuracy using Halcyon megavoltage cone beam CT images (MVCBCT).Materials and methodsPlanning CT images of an anthropomorphic Head phantom were aligned rigidly with MVCBCT and re-sampled to achieve the same resolution, denoted as pCT. MVCBCT was warped with twenty simulated pre-known virtual deformation fields (Ti, i = 1–20) with increasing deformation magnitudes, yielding warped CBCT (wCBCT). The pCT and MVCBCT were registered to wCBCT respectively (Multi-modality and Uni-modality DIR), generating deformation vector fields Vi and Vi′ (i = 1–20). Vi and Vi′ were compared with Ti respectively to assess the DIR accuracy geometrically. In addition, Vi, Ti, and Vi′ were applied to pCT, generating deformed CT (dCTi), ground-truth CT (Gi) and deformed CT′ (dCTi′) respectively. The Hounsfield Unit (HU) on these virtual CT images were also compared.ResultsThe mean errors of vector displacement increased with the deformation magnitude. For deformation magnitudes between 2.82 mm and 7.71 mm, the errors of uni-modality DIR were 1.16 mm ~ 1.73 mm smaller than that of multi-modality (p = 0.0001, Wilcoxon signed rank test). DIR could reduce the maximum signed and absolute HU deviations from 70.8 HU to 11.4 HU and 208 HU to 46.2 HU respectively.ConclusionsAs deformation magnitude increases, DIR accuracy continues to deteriorate and uni-modality DIR consistently outperformed multi-modality DIR. DIR-based adaptive radiotherapy utilizing the noisy MVCBCT images is only conditionally applicable with caution.  相似文献   

19.
AimPatient setup errors were aimed to be reduced in radiotherapy (RT) of head-and-neck (H&N) cancer. Some remedies in patient setup procedure were proposed for this purpose.BackgroundRT of H&N cancer has challenges due to patient rotation and flexible anatomy. Residual position errors occurring in treatment situation and required setup margins were estimated for relevant bony landmarks after the remedies made in setup process and compared with previous results.Materials and methodsThe formation process for thermoplastic masks was improved. Also image matching was harmonized to the vertebrae in the middle of the target and a 5 mm threshold was introduced for immediate correction of systematic errors of the landmarks. After the remedies, residual position errors of bony landmarks were retrospectively determined from 748 orthogonal X-ray images of 40 H&N cancer patients. The landmarks were the vertebrae C1–2, C5–7, the occiput bone and the mandible. The errors include contributions from patient rotation, flexible anatomy and inter-observer variation in image matching. Setup margins (3D) were calculated with the Van Herk formula.ResultsSystematic residual errors of the landmarks were reduced maximally by 49.8% (p  0.05) and the margins by 3.1 mm after the remedies. With daily image guidance the setup margins of the landmarks were within 4.4 mm, but larger margins of 6.4 mm were required for the mandible.ConclusionsRemarkable decrease in the residual errors of the bony landmarks and setup margins were achieved through the remedies made in the setup process. The importance of quality assurance of the setup process was demonstrated.  相似文献   

20.
PurposeTo evaluate the spatial accuracy of a frameless cone-beam computed tomography (CBCT)-guided cranial radiosurgery (SRS) using an end-to-end (E2E) phantom test methodology.Methods and materialsFive clinical SRS plans were mapped to an acrylic phantom containing a radiochromic film. The resulting phantom-based plans (E2E plans) were delivered four times. The phantom was setup on the treatment table with intentional misalignments, and CBCT-imaging was used to align it prior to E2E plan delivery. Comparisons (global gamma analysis) of the planned and delivered dose to the film were performed using a commercial triple-channel film dosimetry software. The necessary distance-to-agreement to achieve a 95% (DTA95) gamma passing rate for a fixed 3% dose difference provided an estimate of the spatial accuracy of CBCT-guided SRS. Systematic (∑) and random (σ) error components, as well as 95% confidence levels were derived for the DTA95 metric.ResultsThe overall systematic spatial accuracy averaged over all tests was 1.4 mm (SD: 0.2 mm), with a corresponding 95% confidence level of 1.8 mm. The systematic (Σ) and random (σ) spatial components of the accuracy derived from the E2E tests were 0.2 mm and 0.8 mm, respectively.ConclusionsThe E2E methodology used in this study allowed an estimation of the spatial accuracy of our CBCT-guided SRS procedure. Subsequently, a PTV margin of 2.0 mm is currently used in our department.  相似文献   