首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 781 毫秒
1.
PurposeTo perform a complete evaluation on radiation doses, received by primary and assistant medical staff, while performing different vascular interventional radiology procedures.Materials and methodsWe evaluated dose received in different body regions during three categories of vascular procedures: lower limb angiography (Angiography), lower limb percutaneous transluminal angioplasty (Angioplasty) and stent graft placement for abdominal aortic aneurysm treatment (A. A. A. Treatment). We positioned the dosimeters near the eye lens, thyroid, chest, abdomen, hands, and feet of the interventional physicians. Equivalent dose was compared with annual dose limits for workers in order to determine the maximum number of procedures per year that each physician could perform. We assessed 90 procedures.ResultsWe found the highest equivalent doses in the A. A. A. Treatment, in which 90% of the evaluations indicated at least one region receiving more than 1 mSv per procedure. Angioplasty was the only procedural modality that provided statistically different doses for different professionals, which is an important aspect on regards to radiological protection strategies. In comparison with the dose limits, the most critical region in all procedures was the eye lens.ConclusionsSince each body region of the interventionist is exposed to different radiation levels, dose distribution measurements are essential for radiological protection strategies. These results indicate that dosimeters placed in abdomen instead of chest may represent more accurately the whole body doses received by the medical staff. Additional dosimeters and a stationary shield for the eye lens are strongly recommended.  相似文献   

2.

In this study, which is the first of its kind in the gulf region, eye doses of interventional cardiologists and nurses were measured using active dosimeters for left and right eyes, in 60 percutaneous coronary interventions in three main hospitals in Kuwait. The dose given in terms of Hp(0.07) per procedure when ceiling suspended screens were used by main operators ranged from 18.5 to 30.3 µSv for the left eye and from 12.6 to 23.6 µSv for the right eye. Taking into account typical staff workload, the results show that the dose limit of 20 mSv/year to the eyes can be exceeded for interventional cardiologists in some situations, which demonstrates the need of using additional effective radiation protection tools, e.g. protective eye spectacles, in addition to the regular and proper use of ceiling suspended screens. With indications of increase in workload, the need for availability of a dedicated active dosimeter for the regular monitoring of eye doses is emphasized.

  相似文献   

3.
PurposeTo analyse the correlations between the eye lens dose estimates performed with dosimeters placed next to the eyes of paediatric interventional cardiologists working with a biplane system, the personal dose equivalent measured on the thorax and the patient dose.MethodsThe eye lens dose was estimated in terms of Hp(0.07) on a monthly basis, placing optically stimulated luminescence dosimeters (OSLDs) on goggles. The Hp(0.07) personal dose equivalent was measured over aprons with whole-body OSLDs. Data on patient dose as recorded by the kerma-area product (PKA) were collected using an automatic dose management system. The 2 paediatric cardiologists working in the facility were involved in the study, and 222 interventions in a 1-year period were evaluated. The ceiling-suspended screen was often disregarded during interventions.ResultsThe annual eye lens doses estimated on goggles were 4.13 ± 0.93 and 4.98 ± 1.28 mSv. Over the aprons, the doses obtained were 10.83 ± 0.99 and 11.97 ± 1.44 mSv. The correlation between the goggles and the apron dose was R2 = 0.89, with a ratio of 0.38. The correlation with the patient dose was R2 = 0.40, with a ratio of 1.79 μSv Gy−1 cm−2. The dose per procedure obtained over the aprons was 102 ± 16 μSv, and on goggles 40 ± 9 μSv. The eye lens dose normalized to PKA was 2.21 ± 0.58 μSv Gy−1 cm−2.ConclusionsMeasurements of personal dose equivalent over the paediatric cardiologist’s apron are useful to estimate eye lens dose levels if no radiation protection devices are typically used.  相似文献   

4.
ObjectivesTo estimate the organ equivalent doses and the effective doses (E) in patient undergoing percutaneous transhepatic biliary drainage (PTBD) examinations, using the MCNP5 and PCXMC2 Monte Carlo-based codes.MethodsThe purpose of this study is to estimate the organ doses to patients undergoing PTBD examinations by clinical measurements and Monte Carlo simulation. Dose area products (DAP) values were assessed during examination of 43 patients undergoing PTBD examination separated into groups based on the gender and the dimensions and location of the beam.ResultsMonte Carlo simulation of photon transport in male and female mathematical phantoms was applied using the MCNP5 and PCXMC2 codes in order to estimate equivalent organ doses. Regarding the PTBD examination the organ receiving the maximum radiation dose was the lumbar spine. The mean calculated HT for the lumbar spine using the MCNP5 and PCXMC2 methods respectively, was 117.25 mSv and 131.7 mSv, in males. The corresponding doses were 139.45 mSv and 157.1 mSv respectively in females. The HT values for organs receiving considerable amounts of radiation during PTBD examinations were varied between 0.16% and 73.2% for the male group and between 1.10% and 77.6% for the female group. E in females and males using MCNP5 and PCXMC2.0 was 5.88 mSv and 6.77 mSv, and 4.93 mSv and 5.60 mSv.ConclusionThe doses remain high compared to other invasive operations in interventional radiology. There is a reasonable good coincidence between the MCNP5 and PCXMC2.0 calculation for most of the organs.  相似文献   

5.
PurposeThe aim of this study was to measure the occupational exposure using active personal dosimeters (APD) in the PET/CT department at different stages of the operation chain i.e. radiopharmaceutical arrival, activity preparation, dispensing, injection, patient positioning, discharge and compare the radiation exposure doses received using two automatic injection/infusion systems. This paper also reflects optimization processes that were performed to reduce occupational exposure.MethodsMeasured APD data were analysed for medical physicists, radiology technologists and administrative staff from 2014 till 2018. For dispensing and injecting 18F-FDG, the automatic infusion/injection system IRIDE (Comecer, Italy) or the automatic fractionator ALTHEA (Comecer, Italy) with wireless injection system WIS (Comecer, Italy) were used. Radiation exposure optimization methods were applied during the data collection period (installation of the transport port, patient management, APD alarm threshold and etc.).ResultsRadiology technologists who perform injection procedures, regardless of the automatic infusion system, received the highest radiation exposure dose. The average doses to the radiology technologists per one study were 1.72 ± 0.33 μSv and 1.16 ± 0.11 μSv with ALTHEA/WIS and IRIDE system, respectively. The average dose for accompanying the patient to the PET/CT scanner and scan procedure was 0.52 ± 0.07 μSv. For the medical physicists, the average dose was 0.29 ± 0.09 µSv. The measured dose for administrative staff was 0.30 ± 0.15 μSv.ConclusionsOccupational exposure can be effectively optimized by different means including staff monitoring with APD, implementation of radiation safety culture and the usage of automatic infusion systems.  相似文献   

6.
ObjectiveThis paper aims to provide some practical recommendations to reduce eye lens dose for workers exposed to X-rays in interventional cardiology and radiology and also to propose an eye lens correction factor when lead glasses are used.MethodsMonte Carlo simulations are used to study the variation of eye lens exposure with operator position, height and body orientation with respect to the patient and the X-ray tube. The paper also looks into the efficiency of wraparound lead glasses using simulations. Computation results are compared with experimental measurements performed in Spanish hospitals using eye lens dosemeters as well as with data from available literature.ResultsSimulations showed that left eye exposure is generally higher than the right eye, when the operator stands on the right side of the patient. Operator height can induce a strong dose decrease by up to a factor of 2 for the left eye for 10-cm-taller operators. Body rotation of the operator away from the tube by 45°–60° reduces eye exposure by a factor of 2. The calculation-based correction factor of 0.3 for wraparound type lead glasses was found to agree reasonably well with experimental data.ConclusionsSimple precautions, such as the positioning of the image screen away from the X-ray source, lead to a significant reduction of the eye lens dose. Measurements and simulations performed in this work also show that a general eye lens correction factor of 0.5 can be used when lead glasses are worn regardless of operator position, height and body orientation.  相似文献   

7.
PurposeThe aim of the present study was to determine the efficiency of six methods for calculate the effective dose (E) that is received by health professionals during vascular interventional procedures.MethodsWe evaluated the efficiency of six methods that are currently used to estimate professionals’ E, based on national and international recommendations for interventional radiology. Equivalent doses on the head, neck, chest, abdomen, feet, and hands of seven professionals were monitored during 50 vascular interventional radiology procedures. Professionals’ E was calculated for each procedure according to six methods that are commonly employed internationally. To determine the best method, a more efficient E calculation method was used to determine the reference value (reference E) for comparison.ResultsThe highest equivalent dose were found for the hands (0.34 ± 0.93 mSv). The two methods that are described by Brazilian regulations overestimated E by approximately 100% and 200%. The more efficient method was the one that is recommended by the United States National Council on Radiological Protection and Measurements (NCRP). The mean and median differences of this method relative to reference E were close to 0%, and its standard deviation was the lowest among the six methods.ConclusionsThe present study showed that the most precise method was the one that is recommended by the NCRP, which uses two dosimeters (one over and one under protective aprons). The use of methods that employ at least two dosimeters are more efficient and provide better information regarding estimates of E and doses for shielded and unshielded regions.  相似文献   

8.
Occupational radiation dose of staff handling 125I assessment at the Benin radioimmunoassay laboratory, have been undertaken from October 2012 to April 2013 to determine level of radiation safety. Equivalent dose to skin, whole body and extremities, were measured by the mean of thermoluminescence dosimetry. Firstly, three permanent workers and two students were provided with finger ring dosimeters to wear at index finger base of both hands. Ring dosimeters were used for four months. Secondly, three permanent workers and three students were provided with badge dosimeters to wear at the chest level. Badge dosimeters were renewed monthly for six months. The exposed ring and badge dosimeters were evaluated in Ghana. Permanent workers highest average equivalent dose received at index finger base of both hands was 142.75 ± 89.54, microSV/2 months and that of students was 34.69 ± 29.23, microSV/2 months. Workers skin exposure was below one third of prescribed dose limits for permanents workers (500mSv/yr) and students (150mSv/yr). Whole body exposure, expressed in mSv/month, of permanent workers and students, respectively ranged from 0.12 to 0.23 and from 0.11 to 0.16. Radio-immuno-assay laboratory workers are weakly exposed to ionizing radiation. They are safe from deterministic effect risk.  相似文献   

9.
The paper presents a study of the radiation doses to eye lens of medical staff during endoscopic retrograde cholangiopancreatography (ERCP) procedures performed in a busy gastroenterology department. For each procedure the dose equivalent to the eye, exposure time, dose rate, Kerma Area Product and fluoroscopy time were recorded. Measurements were performed for a period of two months in four main positions of the operating staff, and then extrapolated to estimate annual doses. The fluoroscopy time per ERCP procedure varied between 1.0 min and 28.8 min, with a mean value of 4.6 min. The calculated mean eye dose per procedure varied between 34.9 μSv and 93.3 μSv. The results demonstrated that if eye protection is not used, annual doses to the eye lens of the gastroenterologist performing the procedure and the anesthesiologist can exceed the dose limit of 20 mSv per year.  相似文献   

10.
PurposeTo determine the eye lens dose of the Interventional Cardiology (IC) personnel using optically stimulated luminescent dosimeter (OSLD) and the prevalence and risk of radiation – associated lens opacities in Thailand.Methods and results48 IC staff, with age- and sex- matches 37 unexposed controls obtained eye examines. Posterior lens change was graded using a modified Merriam-Focht technique by two independent ophthalmologists. Occupational exposure (mSv) was measured in 42 IC staff, using 2 OSLD badges place at inside lead apron and at collar. Annual eye lens doses (mSv) were also measured using 4 nanoDots OSL placed outside and inside lead glass eyewear. The prevalence of radiation-associated posterior lens opacities was 28.6% (2/7) for IC, 19.5% (8/41) for nurses, and 2.7% (1/37) for controls. The average and range of annual whole body effective dose, Hp(10), equivalent dose at skin of the neck, Hp(0.07) and equivalent dose at eye lens, Hp(3) were 0.80 (0.05–6.79), 5.88 (0.14–35.28), and 5.73 (0.14–33.20) mSv respectively. The annual average and range of eye lens dose using nano Dots OSL showed the outside lead glass eyewear on left and right sides as 8.06 (0.17–32.45), 3.55(0.06–8.04) mSv and inside left and right sides as 3.91(0.05–14.26) and 2.44(0.06–6.24) mSv respectively.ConclusionEye lens doses measured by OSLD badges and nano Dot dosimeter as Hp(10), Hp(0.07) and Hp(3). The eyes of the IC personnel were examined annually by two ophthalmologists for the prevalence of cataract induced by radiation.  相似文献   

11.

This work presents the exposure of hands of the personnel of a nuclear medicine department who prepare and administer 68Ga-DOTA-TATE. Dosimetry measurements were performed during three 1-week sessions, for nine production procedures. A total of 360 measurements were made by using high-sensitivity MCP-N thermoluminescent detectors. Annealed detectors were and vacuum-packed in foil and then placed on each fingertip of both hands of five radiochemists and four nurses (one detector for one fingertip). The greatest exposure to ionizing radiation was found on the non-dominant left hand of radiochemists and nurses. A maximum Hp(0.07)/A value of 49.36?±?4.95 mSv/GBq was registered for radiochemists during the 68 Ga-DOTA-DATE activity dispensing procedure. For nurses performing the radiopharmaceutical injection procedure, a corresponding maximum value of 1.28?±?0.13 mSv/GBq was measured, while the mean value for all the nurses was 0.38 mSv/GBq. The dispensing procedure accounted for approximately 60% of the total exposure of radiochemists' fingertips. Based on the results obtained it is recommended that a ring dosimeter should be routinely placed on the middle finger of the non-dominant hand of radiochemists and nurses. Furthermore, it is proposed to systematically train workers in handling open sources of ionizing radiation, with the aim of reducing the required handling time.

  相似文献   

12.
This study aims to estimate the effective radiation dose and organ dose from head CT procedures. It was conducted in three main private hospitals in Khartoum State-Sudan, using Toshiba machines with 64 slices. The total number of patients included in this study was 142 patients (82 males and 60 females). The effective dose and organ dose were calculated by CT Expo software. The effective dose slightly varied among patients according to gender and age. The effective dose for female patients (5.99 mSv) was higher than that for male patients (5.84 mSv), and the pediatric dose (5.46 mSv) was lower than the adults’ dose (5.94 mSv).The dose for eye lens was found lower for male patients (89.117 mSv) than the dose for female patients (94.62) mSv). According to patients’ age: the dose received by the lens of the eye was much lower in pediatric (79.93 mSv) than the adults (92.41 mSv). The dose for thyroid in female patients (33.52 mSv) was higher than the male patients (28 mSv). The pediatric dose (28.34 mSv) was lower than the adults’ dose (30.64 mSv).Departmental imaging protocol and lack of training among hospital staff are expected to be responsible for these variations. Therefore, this study recommends that the CT technologists be trained on suitable strategies to achieve dose optimization. Moreover, patients’ doses must be monitored regularly.  相似文献   

13.
Histerosalpingography (HSG) remains the dominant diagnostic tool for investigation of infertility in women. Conversion factors used to estimate effective (E) and organ doses (HT) from air Kerma area product (KAP) are needed to estimate patient doses in HSG, performed with state-of-the-art fluoroscopic X-ray systems with digital detectors.In this study, estimates of E and HT for six critical organs/tissues, were derived on an individual basis in 120 HSG procedures and in 1410 irradiation events, performed on two X-ray systems from information available through the radiation dose structured report using Monte Carlo methods.Mean values of E and Hovaries were1.0 ± 0.9 mSv and 5.6 ± 5.4 mGy. E/KAP conversion factors of 0.13; 0.18; 0.28 and 0.35 mSv Gy−1cm−2 were established for irradiation events with a Cu filtration of 0.0; 0.1; 0.4 and 0.9 mm. A high agreement was obtained between E estimated through Monte Carlo methods and E/KAP conversion factors accounting separately for the different modes of fluoroscopy and the radiography component of HSG, with a systematic error of 0 mSv and lower/upper limits of agreement of −0.6 and 0.5 mSv. On the contrary, the use of a single coefficient of conversion did not provide accurate estimates of E, showing a bias of −0.4 mSv and lower and upper limits of agreement of −1.9 and 1.2 mSv.An algorithm for the estimation of effective and organ doses from KAP has been established in HSG procedures depending on the Cu filtration in the X-ray irradiation events.  相似文献   

14.
PurposeAdvanced 3D dosimetry is required for verifications of complex dose distributions in modern radiotherapy. Two 3D polymer gel dosimeters, coupled with magnetic resonance (MR) imaging (3 T MRI) readout and data processing with polyGeVero® software, were tested for the verification of calculated 3D dose distributions by a treatment planning system (TPS) and ArcCHECK®–3DVH®, related to eradication of a lung tumour.MethodsN-vinylpyrrolidone-containing 3D polymer gel dosimeters were used: VIC (containing ascorbic acid and copper sulfate pentahydrate) and VIC-T (containing tetrakis(hydroxymethyl)phosphonium chloride). Three remote centers were involved in the dosimeters preparation and irradiation (Poland), and MRI (Austria). Cross beam calibration of the dosimeters and verification of a 3D dose distribution calculated with an Eclipse External Beam TPS and ArcCHECK®–3DVH® were performed. The 3D-to-3D comparisons of the VIC and VIC-T with TPS and ArcCHECK®–3DVH® along with ArcCHECK®–3DVH® versus TPS dose matrixes were performed with the aid of the polyGeVero® by analyzing dose profiles, isodoses lines, gamma index, gamma angle, dose difference, and related histograms.ResultsThe measured MR-relaxation rate (R2 = 1/T2) for the dosimeters relates to the dose, as follows: R2 = 0.0928 ± 0.0008 [Gy−1 s−1] × D [Gy] + 2.985 ± 0.012 [s−1] (VIC) and 0.1839 ± 0.0044 [Gy−1 s−1] × D [Gy] + 2.519 ± 0.053 [s−1] (VIC-T). The 3D-to-3D comparisons revealed a good agreement between the measured and calculated 3D dose distributions.ConclusionsVIC and VIC-T with 3T MRI readout and polyGeVero® showed potential for verifications of calculated irradiation plans. The results obtained suggest the implementation of the irradiation plan for eradication of the lung tumour.  相似文献   

15.
PurposeInterventional radiology techniques cause radiation exposure both to patient and personnel. The radiation dose to the operator is usually measured with dosimeters located at specific points above or below the lead aprons. The aim of this study is to develop and validate two fast Monte Carlo (MC) codes for radiation transport in order to improve the assessment of individual doses in interventional radiology. The proposed methodology reduces the number of required dosemeters and provides immediate dose results.MethodsTwo fast MC simulation codes, PENELOPE/penEasyIR and MCGPU-IR, have been developed. Both codes have been validated by comparing fast MC calculations with the multipurpose PENELOPE MC code and with measurements during a realistic interventional procedure.ResultsThe new codes were tested with a computation time of about 120 s to estimate operator doses while a standard simulation needs several days to obtain similar uncertainties. When compared with the standard calculation in simple set-ups, MCGPU-IR tends to underestimate doses (up to 5%), while PENELOPE/penEasyIR overestimates them (up to 18%). When comparing both fast MC codes with experimental values in realistic set-ups, differences are within 25%. These differences are within accepted uncertainties in individual monitoring.ConclusionThe study highlights the fact that computational dosimetry based on the use of fast MC codes can provide good estimates of the personal dose equivalent and overcome some of the limitations of occupational monitoring in interventional radiology. Notably, MCGPU-IR calculates both organ doses and effective dose, providing a better estimate of radiation risk.  相似文献   

16.
PurposeMost radiation protection programs, regulations and guidance apply specific restrictions to the occupational exposure of pregnant workers. The aim of this study was to compile data from the declared pregnant woman (DPW) radiation protection program over more than 5 years at a large, high-volume, comprehensive oncology academic/medical institution and to evaluate for effectiveness against existing regulations and guidance.MethodsA retrospective review was performed of the data collected as part of the DPW radiation protection program from January 2010 through May 2016, including the number of declared pregnancies, worker category, personal and fetal dosimetry monitoring measurements, workplace modifications, as well as the monthly and total recorded badge results during the entire pregnancy.Results245 pregnancies were declared. The mean monthly fetal radiation dosimetry result was 0.009 mSv with a median of 0.005 mSv and a maximum of 0.39 mSv. The mean total dose over the entire pregnancy was estimated to be 0.08 mSv with a median of 0.05 mSv and a maximum of 0.89 mSv. Only 8 (3.2%) of the 245 declared pregnancies required that workplace modifications be implemented for the worker.ConclusionsThe implementation of a declared pregnancy and fetal assessment program, careful planning, an understanding of the risks, and minimization of radiation dose by employing appropriate radiation safety measures as needed, can allow medical staff to perform procedures and normal activities without incurring significant risks to the conceptus, or significant interruptions of job activities for most medical workers.  相似文献   

17.
PurposeTo estimate the number of patients in OECD (Organization for Economic Co-operation and Development) countries who receive a cumulative effective dose (CED) ≥ 100 mSv from recurrent computed tomography (CT) exams.MethodsTaking into account recently published data on the number of CTs per patient and the fraction of patients with CED ≥ 100 mSv as well as country-specific data for the number of CT exams/1,000 population from OECD publication, this paper makes estimations for 35 OECD countries.ResultsThe estimated total number of patients with CED ≥ 100 mSv for all 35 OECD countries combined in a 5-year period is around 2.5 million (2,493,685) in a population of 1.2 billion (1,176,641,900), i.e., 0.21% of the population. Expressed per 1,000 population, the range is from 0.51 for Finland to 2.94 for the US, a nearly six-fold difference. Countries with more than 2 patients with CED ≥ 100 mSv in a 5-yr period per 1,000 population are: Belgium, France, Iceland, Japan, Korea, Luxembourg, Portugal, Turkey, and US.ConclusionsThe first estimates of the number of patients likely receiving CED ≥ 100 mSv through recurrent CT exams in 35 OECD countries indicate that 2.5 million patients reach this level in a 5-year period. There is an urgent need for various stakeholders including medical physicists, referring physicians, health policy makers, manufacturers of CT equipment and epidemiologists to attend to the issue in the interest of patient radiation safety.  相似文献   

18.
BackgroundThe Euratom directive 97/43 recommends the use of patient dose surveys in diagnostic radiology and the establishment of reference dose levels (DRLs).PurposeTo perform measurements of the dose delivered during diagnostic angiography of the lower limbs using thermoluminescence dosimeters (TLDs), extraction of DRLs and estimation of the effective dose and radiation risk for this particular examination.MethodsDose measurement was performed on 30 patients by using TLD sachets attached in 5 different positions not only on the patient, but also to the radiologist. All the appropriate factors were recorded. Measurement of the ESD was performed after each examination.ResultsThe mean entrance skin dose (ESD) was calculated to be 70.8, 67.7, 24.3, 18.4, 9.7 mGy at the level of aorta bifurcation, pelvis, femur, knees, and at feet, respectively. The average effective dose is 9.8 mSv with the radiation risks for fatal cancer to be 5.4 × 10?4. The effective dose of the radiologist was calculated to be 0.023 mSv per procedure.ConclusionRadiation dose variation depends on the physical characteristics of the patient, on the procedure preferences by radiologists and the difficulties in conducting procedures. The main reason for the increased patient dose, compared to other studies, is the number of frames rather than the duration of fluoroscopy. For DSA of the lower limbs, the DRL was chosen to be an entrance skin dose of 96.4 mGy in the pelvic region. The dose to the radiologist is negligible.  相似文献   

19.
Rheumatoid arthritis (RA) is a chronic inflammatory disease that can potentially damage the synovial joints. One of the effective treatment modality for RA is radiation synovectomy (RSV) where properly selected radionuclide is injected into the joint space, enabling controlled destruction of diseased synovial membrane via radiation exposure. Radiation dosimetry in RSV appears challenging due to the heterogeneous nature of synovial membrane, nonuniform distribution and leakage of radionuclide from the synovial cavity. This article reviews the dosimetric perspective pertaining to RSV. Specifically, characteristics of radionuclide for RSV and radiation dose to target and non-target (i.e., articular cartilage, bone, bloodstream, gonads, etc.) tissues of patient have been discussed. The personal dose Hp(0.07) to the hands of medical staff (i.e., radiochemist, therapist physician, nurse) may be considerably high due to handling of high specific activities (∼500 MBq/ml for Y-90); such doses are typically measured using thermoluminescence dosimeters (TLD) ring dosimeters and ranges from 1 to 21.5, 0.1 to 40 and 0.1 to 5 µSv/MBq for the radiochemist, therapist physician and the nurse, respectively. Methods to minimize radiation doses to the patient, medical staff and public are elaborated. Contamination risks and precautionary measures are also reported.  相似文献   

20.
IntroductionSentinel node biopsy is a procedure used for axillary nodal staging in breast cancer surgery. The process uses radioactive 99mTc isotope for mapping the sentinel node(s) and all the staff involved in the procedure is potentially exposed to ionizing radiation. The colloid for radiolabelling (antimone-sulphide) with 99mTc isotope (half-life 6 h) is injected into the patient breast. The injection has activity of 18.5 MBq. The surgeon removes the primary tumor and detects active lymph nodes with gamma detection unit. The tumor as well as the active nodal tissue is transferred to pathologist for the definitive findings. The aim of the study was to measure dose equivalents to extremities and whole body for all staff and suggest practice improvement in order to minimize exposure risk.Materials and methodsThe measurements of the following operational quantities were performed: Hp(10) personal dose equivalent to whole body and Hp(0.07) to extremities for staff as well as ambiental dose for operating theatre and during injection.Hp(0.07) were measured at surgeon’s finger by ring thermoluminescent dosimeter (TLD) type MTS-N, and reader RADOS RE2000. Surgeon and nurse were wearing TLD personal dosimeter at the chest level. Anesthesiologist and anesthetist were wearing electronic personal dosimeters, while pathologist was wearing ring TLD while manipulating tissue samples.Electronic dosimeters used were manufactured by Polimaster, type PM1610.All TLD and electronic dosimeters data were reported, including background radiation. Background radiation was also monitored separately. Personal TLDs are standard for this type of personal monitoring, provided by accredited laboratory.Measurements of ambiental dose in workplaces of other staff involved around the patient was performed before the surgery took place, by calibrated survey meters manufactured by Atomtex, type 1667.The study involved two surgeons and one pathologist, two anesthesiologists and three anesthetists during two months period.Results and discussionThe doses received by all staff are evaluated using passive and active personal dosimeters and ambiental dose monitors and practice was improved based on results collected. Average annual whole body dose for all staff involved in the procedure was less than 0.8 mSv. Extremity dose equivalents to surgeon and pathologist were far below the limits set for professionally exposed (surgeon) and for public (pathologist).ConclusionsAlthough has proven to be very safe for all staff, additional measures for radiation protection, in accordance to ALARA principle (As Low As Reasonably Achievable) should be conducted. The recommendations for practice improvement with respect to radiation protection were issued.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏