首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Studies that seek to determine the effects of an intervention on knee biomechanics during landing from a jump implicitly assume that the variables of interest are reliable both within and between data collection sessions. Currently, such reliability data are not available for a stop jump. Standard three-dimensional motion analysis was used to determine sagittal and frontal plane peak angles and moments and peak vertical ground reaction force within and between sessions for a stop jump. Twelve female recreational athletes participated in two data collection sessions spaced two weeks apart. Interclass correlation coefficients and coefficient of multiple correlation were used to determine within and between session reliability of peak knee flexion angle, peak internal knee extension moment, peak knee abduction angle, peak internal knee adduction moment and peak vertical ground reaction force. Overall reliability within a session (ICC (3,1) 0.631-0.881; CMC 0.672-0.958) and between sessions (ICC (3,k) 0.685-0.959; CMC 0.598-0.944) was good. Peak angles and moments were similar between sessions. The stop jump is less reliable within a session than a drop vertical jump reported previously in the literature. This is likely due to increased intrasubject variability between trials due to the less constrained nature of the task. Reliability of the stop jump is comparable to the drop vertical jump between sessions. Reliability of knee adduction moment is lower than reported for the drop vertical jump. The results of this study support the use of a stop jump task to evaluate knee biomechanics during landing in longitudinal studies with a repeated measures design.  相似文献   

2.
Tensiomyography (TMG) is a relatively novel technique to assess muscle mechanical response based on radial muscle belly displacement consecutive to a single electrical stimulus. Although intra-session reliability has been found to be good, inter-rater reliability and the influence of sensor repositioning and electrodes placement on TMG measurements is unknown. The purpose of this study was to analyze the inter-rater reliability of vastus medialis muscle contractile property measurements obtained with TMG as well as the effect of inter-electrode distance (IED). Five contractile parameters were analyzed from vastus medialis muscle belly displacement–time curves: maximal displacement (Dm), contraction time (Tc), sustain time (Ts), delay time (Td), and half-relaxation time (Tr). The inter-rater reliability and IED effect on these measurements were evaluated in 18 subjects. Intra-class correlation coefficients, standard errors of measurement, Bland and Altman systematic bias and random error as well as coefficient of variations were used as measures of reliability. Overall, a good to excellent inter-rater reliability was found for all contractile parameters, except Tr, which showed insufficient reliability. Alterations in IED significantly affected Dm with a trend for all the other parameters. The present results legitimate the use of TMG for the assessment of vastus medialis muscle contractile properties, particularly for Dm and Tc. It is recommended to avoid Tr quantification and IED modifications during multiple TMG measurements.  相似文献   

3.
This study aimed to evaluate test and retest reliability according to examiner experience with the three-dimensional kinematics of the trunk, scapula, and arm segments during flexion and unilateral abduction of the arm. Ten men and 10 women (mean age, 25.1 [1.1] years) participated in this study. Each volunteer participated in six test sessions, four on the first day (two for each examiner) and two on the second day (one for each examiner). A 48-h interval was given between test days. The assessments were made by one examiner with movement analysis experience and a second examiner without experience. For each session (intra-day), the volunteers performed five repetitions of unilateral arm flexions and abductions using their dominant arms. After 1 h, the data were re-collected and all markers were replaced. Data from the trunk, scapula, and arm were analysed at 30°, 60°, 90°, and 120° of arm flexion and abduction using intraclass coefficient correlation, standard error of the measurement, and analysis of variance. The results did not differ between the experienced and inexperienced examiners except for trunk axial rotation at all studied angles and for arm rotation at 120° of abduction. The examiner previously trained in movement analysis marker placement demonstrated the same intra-tester reliability as the inexperienced tester when marker placement accuracy was the variable of interest.  相似文献   

4.
This study examined the reliability and scaling of the flexor carpi radialis (FCR) V-wave during submaximal and maximal voluntary muscle contractions (MVC). 23 participants were tested on three separate sessions. For each session, participants performed isometric wrist flexions at five contraction levels (20, 40, 60, 80 and 100 %MVC). When the target contraction level was reached, a supramaximal electrical stimulus was applied to the median nerve in order to elicit an FCR V-wave. Across all participants, the FCR V-wave amplitude, normalized to its superimposed M-wave amplitude, increased from 0.030 ± 0.001 to 0.143 ± 0.015 (P < 0.001) as the muscle contraction increased from 20 to 100 %MVC. Contraction level did not influence the reliability of evoking the FCR V-wave, as the V-wave demonstrated both stability and consistency. With the exception of a single day main effect during the 20 %MVC condition, V:Msup was not different across days or trials (P > 0.05) indicating measurement stability. High reliability co-efficients (0.827–0.913) at each contraction level signified measurement consistency. This study establishes that FCR V-waves can be reliably evoked during both submaximal and maximal muscle contractions and suggests the possibility for FCR V-wave recordings to be used to document neuromuscular adaptations associated with factors such as training or fatigue.  相似文献   

5.
Previous studies evaluated 3D human jaw movements using kinematic analysis systems during mouth opening, but information on the reliability of such measurements is still scarce. The purpose of this study was to analyze within- and between-session reliabilities, inter-rater reliability, standard error of measurement (SEM), minimum detectable change (MDC) and consistency of agreement across raters and sessions of 3D kinematic variables during maximum mouth opening (MMO). Thirty-six asymptomatic subjects from both genders were evaluated on two different days, five to seven days apart. Subjects performed three MMO movements while kinematic data were collected. Intraclass correlation coefficient (ICC), SEM and MDC were calculated for all variables, and Bland-Altman plots were constructed. Jaw radius and width were the most reproducible variables (ICC > 0.81) and demonstrated minor error. Incisor displacement during MMO and angular movements in the sagittal plane presented good reliability (ICC from 0.61 to 0.8) and small errors and, consequently, could be used in future studies with the same methodology and population. The variables with smaller amplitudes (condylar translations during mouth opening and closing and mandibular movements on the frontal and transversal planes) were less reliable (ICC < 0.61) and presented larger SEM and MDC. Although ICC, SEM and MDC showed less between-session reproducibility than within-session and inter-rater, the limits of agreement were larger in inter-rater comparisons. In future studies care must be taken with variables collected on different days and with mandibular movements in the frontal and transversal planes.  相似文献   

6.
Knowledge of three-dimensional scapular movements is essential to understand post-stroke shoulder pain. The goal of the present work is to determine the feasibility and the within and between session reliability of a movement protocol for three-dimensional scapular movement analysis in stroke patients with mild to moderate impairment, using an optoelectronic measurement system. Scapular kinematics of 10 stroke patients and 10 healthy controls was recorded on two occasions during active anteflexion and abduction from 0° to 60° and from 0° to 120°. All tasks were executed unilaterally and bilaterally. The protocol’s feasibility was first assessed, followed by within and between session reliability of scapular total range of motion (ROM), joint angles at start position and of angular waveforms. Additionally, measurement errors were calculated for all parameters. Results indicated that the protocol was generally feasible for this group of patients and assessors. Within session reliability was very good for all tasks. Between sessions, scapular angles at start position were measured reliably for most tasks, while scapular ROM was more reliable during the 120° tasks. In general, scapular angles showed higher reliability during anteflexion compared to abduction, especially for protraction. Scapular lateral rotations resulted in smallest measurement errors. This study indicates that scapular kinematics can be measured reliably and with precision within one measurement session. In case of multiple test sessions, further methodological optimization is required for this protocol to be suitable for clinical decision-making and evaluation of treatment efficacy.  相似文献   

7.
Alterations in scapular muscle activity, including excess activation of the upper trapezius (UT) and onset latencies of the lower trapezius (LT) and serratus anterior (SA) muscles, are associated with abnormal scapular motion and shoulder impingement. Limited information exists on the reliability of neuromuscular activity to demonstrate the efficacy of interventions. The purpose of this study was to characterize the reproducibility of scapular muscle activity (mean activity, relative onset timing) over time and establish the minimal detectable change (MDC). Surface electromyography (sEMG) of the UT, LT, SA and anterior deltoid (AD) muscles in 16 adults were captured during an overhead lifting task in two sessions, one-week apart. sEMG data were also normalized to maximum isometric contraction and the relative onset and mean muscle activity during concentric and eccentric phases of the scapular muscles were calculated. Additionally, reliability of the absolute sEMG data during the lifting task and MVIC was evaluated. Both intrasession and intersession reliability of normalized and absolute mean scapular muscle activity, assessed with intraclass correlation coefficients (ICC), ranged from 0.62 to 0.99; MDC values were between 1.3% and 11.7% MVIC and 24 to 135 mV absolute sEMG. Reliability of sEMG during MVIC was ICC = 0.82–0.99, with the exception of intersession upper trapezius reliability (ICC = 0.36). Within session reliability of muscle onset times was ICC = 0.88–0.97, but between session reliability was lower with ICC = 0.43–0.73; MDC were between 39 and 237 ms. Small changes in scapular neuromuscular mean activity (>11.7% MVIC) can be interpreted as meaningful change, while change in muscle onset timing in light of specific processing parameters used in this study is more variable.  相似文献   

8.

Introduction

Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power.

Methods

30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change.

Results

Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79).

Conclusions

Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations.  相似文献   

9.
The purpose of this study was to compare the use of intramuscular (iEMG) and surface (sEMG) electromyography electrodes to record flexor hallucis longus (FHL) muscle activity during walking, and describe the role of the FHL. Muscle activity was recorded in 12 participants using sEMG and iEMG during treadmill and overground walking. Inter-tester reliability for visual detection of onset and offset of muscle activity was high (ICC = 1.00). During the loading period, the number of bursts of muscle activity was statistically significantly greater using iEMG compared to sEMG when treadmill walking (p = 0.016), and the duration of muscle activity was significantly greater for iEMG (p = 0.01) on both walking surfaces. There were no differences for peak and mean root mean squared (p ≥ 0.07). The FHL activity observed during the loading period (heel strike to forefoot strike) supports the function of the FHL to act as a dynamic ankle stabiliser of the rearfoot, as well as contributing to propulsion during the latter part of stance. The choice of electrodes to detect FHL activity should be dependent on whether the loading and propulsive periods are of interest, and whether treadmill or overground walking will be examined.  相似文献   

10.

Objective

Tools to better evaluate the impact of therapy on nerve and muscle disease are needed. Electrical impedance myography (EIM) is sensitive to neuromuscular disease progression as well as to therapeutic interventions including myostatin inhibition and antisense oligonucleotide-based treatments. Whether the technique identifies the impact of electrical muscle stimulation (EMS) is unknown.

Methods

Ten wild-type (wt) C57B6 mice and 10 dystrophin-deficient (mdx) mice underwent 2 weeks of 20 min/day EMS on left gastrocnemius and sham stimulation on the right gastrocnemius. Multifrequency EIM data and limb girth were obtained before and at the conclusion of the protocol. Muscle weight, in situ force measurements, and muscle fiber histology were also assessed at the conclusion of the study.

Results

At the time of sacrifice, muscle weight was greater on the EMS-treated side than on the sham-stimulated side (p = 0.018 for wt and p = 0.007 for mdx). Similarly, in wt animals, EIM parameters changed significantly compared to baseline (resistance (p = 0.009), reactance (p = 0.0003) and phase (p = 0.002); these changes were due in part to reductions in the EIM values on the EMS-treated side and elevations on the sham-simulated side. Mdx animals showed analogous but non-significant changes (p = 0.083, p = 0.064, and p = 0.57 for resistance, reactance and phase, respectively). Maximal isometric force trended higher on the stimulated side in wt animals only (p = 0.06). Myofiber sizes in wt animals were also larger on the stimulated side than on the sham-stimulated side (p = 0.034); no significant difference was found in the mdx mice (p = 0.79).

Conclusion

EIM is sensitive to stimulation-induced muscle alterations in wt animals; similar trends are also present in mdx mice. The mechanisms by which these EIM changes develop, however, remains uncertain. Possible explanations include longer-term trophic effects and shorter-term osmotic effects.  相似文献   

11.
The purpose of this study was to determine the intratester reliability of surface electromyography (EMG) assessment of the gluteus medius muscle in healthy people and people with chronic nonspecific low back pain (CNLBP) during barefoot walking. Gluteus medius muscle activity was measured twice in 40 people without and 30 people with CNLBP approximately 7 days apart. Walking gluteus medius muscle activity was normalised to maximal voluntary isometric contractions during side-lying hip abduction with manual resistance. Good intratester reliability (ICC > 0.75) was found for mean, peak, and peak to peak amplitude for healthy people. Only mean amplitude demonstrated good intratester reliability in those with CNLBP. Peak amplitude and peak to peak amplitude of the gluteus medius muscle of those with CNLBP, and the time of peak amplitude in both groups, demonstrated moderate reliability (ICC ranged from 0.50 to 0.58). Moderate to large standard error of measurement and minimal detectable change values were reported for outcome measurements. These results suggest that potentially large levels of random error can occur between sessions. Future research can build on this study for those with pathology and attempt to establish change values for EMG that are clinically meaningful.  相似文献   

12.
Muscle synergies have been investigated during different types of human movement using nonnegative matrix factorization. However, there are not any reports available on the reliability of the method. To evaluate between-day reliability, 21 subjects performed bench press, in two test sessions separated by approximately 7 days. The movement consisted of 3 sets of 8 repetitions at 60% of the three repetition maximum in bench press. Muscle synergies were extracted from electromyography data of 13 muscles, using nonnegative matrix factorization. To evaluate between-day reliability, we performed a cross-correlation analysis and a cross-validation analysis, in which the synergy components extracted in the first test session were recomputed, using the fixed synergy components from the second test session. Two muscle synergies accounted for >90% of the total variance, and reflected the concentric and eccentric phase, respectively. The cross-correlation values were strong to very strong (r-values between 0.58 and 0.89), while the cross-validation values ranged from substantial to almost perfect (ICC3, 1 values between 0.70 and 0.95). The present findings revealed that the same general structure of the muscle synergies was present across days and the extraction of muscle synergies is thus deemed reliable.  相似文献   

13.
The objective of the present study was to establish test–retest reliability of isokinetic hip torque and prime mover electromyogram (EMG) through the three cardinal planes of motion. Thirteen healthy young adults participated in two experimental sessions, separated by approximately one week. During each session, isokinetic hip torque was evaluated on the Biodex Isokinetic Dynamometer at a velocity of 60 deg/s. Subjects performed three maximal-effort concentric and eccentric contractions, separately, for right and left hip abduction/adduction, flexion/extension, and internal/external rotation. Surface EMGs were sampled from the gluteus maximus, gluteus medius, adductor, medial and lateral hamstring, and rectus femoris muscles during all contractions. Intraclass correlation coefficients (ICC – 2,1) and standard errors of measurement (SEM) were calculated for peak torque for each movement direction and contraction mode, while ICCs were only computed for the EMG data. Motions that demonstrated high torque reliability included concentric hip abduction (right and left), flexion (right and left), extension (right) and internal rotation (right and left), and eccentric hip abduction (left), adduction (left), flexion (right), and extension (right and left) (ICC range = 0.81–0.91). Motions with moderate torque reliability included concentric hip adduction (right), extension (left), internal rotation (left), and external rotation (right), and eccentric hip abduction and adduction (right), flexion (left), internal rotation (right and left), and external rotation (right and left) (ICC range = 0.49–0.79). The majority of the EMG sampled muscles (n = 12 and n = 11 for concentric and eccentric contractions, respectively) demonstrated high reliability (ICC = 0.81–0.95). Instances of low, or unacceptable, EMG reliability values occurred for the medial hamstring muscle of the left leg (both contraction modes) and the adductor muscle of the right leg during eccentric internal rotation. The major finding revealed high and moderate levels of between-day reliability of isokinetic hip peak torque and prime mover EMG. It is recommended that the day-to-day variability estimates concomitant with acceptable levels of reliability be considered when attempting to objectify intervention effects on hip muscle performance.  相似文献   

14.
Testosterone is commonly thought to drive male sexual interest, but little experimental evidence demonstrates a direct relationship between natural variation in testosterone and sexual interest in healthy young men. This study measured young men's testosterone levels and their interest in visual sexual stimuli across three test sessions within 1 month. Fifteen men aged 23–28 viewed pictures of couples engaged in sexually explicit activity. Each session included a unique set of 72 pictures depicting heterosexual oral sex or intercourse presented in randomized order. Participants controlled how long they viewed each picture, with viewing time indicating sexual interest. Men's testosterone (T) levels were assayed from blood spots obtained prior to viewing the pictures. Overall, T and viewing time were positively correlated; however, the strength of this relationship varied by test session. T was marginally correlated with viewing time during the first session (r = 0.43) and not significantly correlated with viewing time on the second session (r = 0.16). During the final test session, when habituation might influence male interest in the stimuli, T was strongly correlated with viewing time (r = 0.80). Thus, the current study demonstrates a direct but context dependent relationship between testosterone and sexual interest in healthy young males.  相似文献   

15.
Despite the common use of standardised methods analysing neuromuscular function during knee extension, there is a lack of test-retest reliability studies. Furthermore, for most of the investigated variables it is unknown which changes of values indicate an enhancement of performance. The aim of the present study was to investigate performance-dependent variations of muscle functions during isometric contraction of knee extensors and to examine test-retest reliability of their measurement methods. For test-retest reliability sports students completed three test sessions. Highly skilled athletes, sports students and untrained subjects were investigated to determine the performance-dependent variations. The following variables were analysed: maximal voluntary contraction (MVC), voluntary activation (VA), absolute muscle reaction time (AR), muscle endurance (ME), and EMG frequency analysis (MF) of m. vastus lateralis (VL), m. vastus medialis (VM) and m. rectus femoris (RF). RESULTS TEST-RETEST-RELIABILITY: A high reliability between session 1 vs. 2 and session 2 vs. 3 was shown for MVC (ICC=0.92 and .97), VA (0.92/0.95) and ME (0.87/0.95). ICC in AR (0.23) was low between the first and second session and moderate between the second and third session (0.74). MF of VL, VM and RF showed low ICC between sessions. PERFORMANCE DEPENDENT VARIATIONS: Significant differences in nearly all variables (except VA) were found between trained (athletes and sports students) and untrained subjects.  相似文献   

16.
In this study, we aimed to compare the intrarater reliability and validity of muscle thickness measured using ultrasonography (US) and muscle activity via electromyography (EMG) during manual muscle testing (MMT) of the external oblique (EO) and lumbar multifidus (MF) muscles. The study subjects were 30 healthy individuals who underwent MMT at different grades. EMG was used to measure the muscle activity in terms of ratio to maximum voluntary contraction (MVC) and root mean square (RMS) metrics. US was used to measure the raw muscle thickness, the ratio of muscle thickness at MVC, and the ratio of muscle thickness at rest. One examiner performed measurements on each subject in 3 trials. The intrarater reliabilities of the % MVC RMS and raw RMS metrics for EMG and the % MVC thickness metrics for US were excellent (ICC = 0.81–0.98). There was a significant difference between all the grades measured using the % MVC thickness metric (p < 0.01). Further, this % MVC thickness metric of US showed a significantly higher correlation with the EMG measurement methods than with the others (r = 0.51–0.61). Our findings suggest that the % MVC thickness determined by US was the most sensitive of all methods for assessing the MMT grade.  相似文献   

17.

Objective

To test a method for performing electrical impedance myography (EIM) in the mouse hind limb for the assessment of disease status in neuromuscular disease models.

Methods

An impedance measuring device consisting of a frame with electrodes embedded within an acrylic head was developed. The head was rotatable such that data longitudinal and transverse to the major muscle fiber direction could be obtained. EIM measurements were made with this device on 16 healthy mice and 14 amyotrophic lateral sclerosis (ALS) animals. Repeatability was assessed in both groups.

Results

The technique was easy to perform and provided good repeatability in both healthy and ALS animals, with intra-session repeatability (mean ± SEM) of 5% ±1% and 12% ±2%, respectively. Significant differences between healthy and ALS animals were also identified (e.g., longitudinal mean 50 kHz phase was 18±0.6° for the healthy animals and 14±1.0° for the ALS animals, p = 0.0025).

Conclusions

With this simple device, the EIM data obtained is highly repeatable and can differentiate healthy from ALS animals.

Significance

EIM can now be applied to mouse models of neuromuscular disease to assess disease status and the effects of therapy.  相似文献   

18.
The aim was to 1) determine intersession and intertrial reliability and 2) assess three sources of variability (intersubject, intersession and intertrial) of lower limb kinematic and electromyographic (EMG) variables during gait in toddlers with typical development (TD) and unilateral cerebral palsy (UCP) (age <3 years, independent walking experience ≤6 months). Gait kinematics and surface EMG were recorded in 30 toddlers (19 TD and 11 UCP), during two, 3D-motion capture sessions. Standard error of measurement (SEM) between trials (gait cycles) of the same session and between sessions was calculated to assess reliability. Standard deviations (SD) between subjects, sessions and trials were calculated to estimate sources of variability. Sixty-four percent of kinematic SEM-values were acceptable (2°-5°). Frontal plane measurements were most reliable (SEM 2°-4.6°). In toddlers with UCP, EMG variables were most reliable for affected side, distal muscles. Intrinsic (intertrial and intersubject) variability was high, reflecting both motor immaturity and the high variability of toddler gait patterns. In toddlers with UCP, variability was amplified by motor impairment and delayed motor development. 3D gait analysis and surface EMG are partially reliable tools to study individual gait patterns in toddlers in clinical practice and research, although some variables must be interpreted with caution.  相似文献   

19.
The primary objective of this study was to investigate the reliability of the myotonometer in the mechanical properties of the forearm muscles [m. extensor carpi radialis brevis (ECRB), and m. flexor carpi ulnaris (FCU)] in healthy individuals. The secondary objective was to investigate the relationship between the handgrip strength and mechanical properties of these forearm muscles. The mechanical properties (muscle tone, stiffness, and elasticity) of the ECRB and FCU were measured using the MyotonPRO device. Examiner 1 performed two sets of measurements with a time interval of 30 min to determine intra-examiner reliability. Examiner 2 performed measurements during the interval between the two sets of examiner 1. The intra- and inter-examiner reliabilities were excellent (ICC˃0.82) for muscle tone, stiffness, and elasticity of the FCU. Both intra- and inter-examiner reliability in the evaluation of ECRB muscle tone, elasticity, and stiffness was moderate to excellent (ICCs = 0.56–0.98). The muscle tone and stiffness properties of the FCU were positively correlated with the handgrip strength (p <.05). The study findings indicate that the MyotonPRO device is a reliable tool to quantify ECRB, and FCU muscles mechanical properties in healthy individuals.  相似文献   

20.
Effects of isometric training on skeletal myosin heavy chain expression   总被引:2,自引:0,他引:2  
This studytested the hypothesis that an isometric resistance-training programinduces upregulation of slow myosin heavy chain (MHC) expression in afast-twitch skeletal muscle. Thus we studied the effects of tworesistance-training programs on rodent medial gastrocnemius (MG) musclethat were designed to elicit repetitive isometric contractions(10-12 per set; 4 sets per session) of different duration (8 vs. 5 s) and activation frequency (100 vs. 60 Hz) per contraction during eachtraining session (total of 6 and 12 sessions). Results showed that bothtraining paradigms produced significant increases in muscle weight(~11-13%) after completion of training(P < 0.05). Significanttransformations in MHC expression occurred and involved specifically adecrease in the relative expression of the fast type IIb MHC andconcomitant increased expression of the fast type IIx MHC.These adaptations were observed in both the "white" and"red" regions of the MG, and they occurred at both the mRNA andprotein levels. These adaptations were detected after onlysix training sessions. Neither of the training programs produced anychange in the relative expression of either the slow type I MHC or themoderately fast type IIa MHC, which can be upregulated in the red MG bychronic functional overload. These findings show that theisometric protocols used in this investigation were not sufficient toinduce the hypothesized changes in the myosin heavy chain isoformexpression in rodent skeletal muscle.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号