 共查询到20条相似文献,搜索用时 15 毫秒
1.
In recent years one of the areas of interest in radiotherapy has been adaptive radiation therapy (ART), with the most efficient way of performing ART being the use of deformable image registration (DIR). In this paper we use the distances between points of interest (POIs) in the computed tomography (CT) and the cone beam computed tomography (CBCT) acquisition images and the inverse consistence (IC) property to validate the RayStation treatment planning system (TPS) DIR algorithm. This study was divided into two parts: Firstly the distance-accuracy of the TPS DIR algorithm was ascertained by placing POIs on anatomical features in the CT and CBCT images from five head and neck cancer patients. Secondly, a method was developed for studying the implication of these distances on the dose by using the IC. This method compared the dose received by the structures in the CT, and the structures that were quadruply-deformed. The accuracy of the TPS was 1.7 ± 0.8 mm, and the distance obtained with the quadruply-deformed IC method was 1.7 ± 0.9 mm, i.e. the difference between the IC method multiplied by two, and that of the TPS validation method, was negligible. Moreover, the IC method shows very little variation in the dose-volume histograms when comparing the original and quadruply-deformed structures. This indicates that this algorithm is useful for planning adaptive radiation treatments using CBCT in head and neck cancer patients, although these variations must be taken into account when making a clinical decision to adapt a treatment plan.  相似文献   

2.
IntroductionDeformable image registration (DIR) can play an important role in the context of adaptive radiotherapy. The AAPM Task Group 132 (TG-132) has described several quantitative measures for DIR error assessment but they can only be accurately defined when there is a ground-truth present in high-contrast regions. This work aims to set out a framework to obtain optimal results for CT-CT lung DIR in clinical setting for a commercially available system by quantifying the DIR performance in both low- and high-contrast regions.MethodsFive publicly available thorax datasets were used to assess the DIR quality. A “Ghost fiducial” method was implemented by windowing the contrast in a new feature provided by Varian Velocity v4.1. Target registration error (TRE) of the landmarks and Dice-similarity coefficient of the tumour were calculated at three different contrast settings to assess the algorithm in high- and low-contrast scenarios.ResultsFor the original unedited dataset, higher resolution DIR methods showed best performance acceptable within the recommended limit according to TG-132, when actual displacements were less than 10 mm. The relation of the actual displacement of the landmarks and TRE shows the limited capacity of the algorithm to deal with movements larger than 10 mm.ConclusionThis work found the performance of DIR methods and settings available in Varian Velocity v4.1 to be a function of contrast level as well as extent of motion. This highlights the need for multiple metrics to assess different aspects of DIR performance for various applications related to low-contrast and/or high-contrast regions.  相似文献   

3.
PurposeTo report the commissioning and validation of deformable image registration(DIR) software for adaptive contouring.MethodsDIR (SmartAdapt®v13.6) was validated using two methods namely contour propagation accuracy and landmark tracking, using physical phantoms and clinical images of various disease sites. Five in-house made phantoms with various known deformations and a set of 10 virtual phantoms were used. Displacement in lateral, anterio-posterior (AP) and superior-inferior (SI) direction were evaluated for various organs and compared with the ground truth. Four clinical sites namely, brain (n = 5), HN (n = 9), cervix (n = 18) and prostate (n = 23) were used. Organs were manually delineated by a radiation oncologist, compared with the deformable image registration (DIR) generated contours. 3D slicer v4.5.0.1 was used to analyze Dice Similarity Co-efficient (DSC), shift in centre of mass (COM) and Hausdorff distances Hf95%/avg.ResultsMean (SD) DSC, Hf95% (mm), Hfavg (mm) and COM of all the phantoms 1–5 were 0.84 (0.2) mm, 5.1 (7.4) mm, 1.6 (2.2) mm, and 1.6 (0.2) mm respectively. Phantom-5 had the largest deformation as compared to phantoms 1–4, and hence had suboptimal indices. The virtual phantom resulted in consistent results for all the ROIs investigated. Contours propagated for brain patients were better with a high DSC score (0.91 (0.04)) as compared to other sites (HN: 0.84, prostate: 0.81 and cervix 0.77). A similar trend was seen in other indices too. The accuracy of propagated contours is limited for complex deformations that include large volume and shape change of bladder and rectum respectively. Visual validation of the propagated contours is recommended for clinical implementation.ConclusionThe DIR algorithm was commissioned and validated for adaptive contouring.  相似文献   

4.
The purpose of this study was to develop a novel dynamic deformable thorax phantom for deformable image registration (DIR) quality assurance (QA) and to verify as a tool for commissioning and DIR QA.The phantom consists of a base phantom, an inner phantom, and a motor-derived piston. The base phantom is an acrylic cylinder phantom with a diameter of 180 mm. The inner phantom consists of deformable, 20 mm thick disk-shaped sponges. To evaluate the physical characteristics of the phantom, we evaluated its image quality and deformation. DIR accuracies were evaluated using the three types of commercially DIR software (MIM, RayStation, and Velocity AI) to test the feasibility of this phantom. We used different DIR parameters to test the impact of parameters on DIR accuracy in various phantom settings. To evaluate DIR accuracy, a target registration error (TRE) was calculated using the anatomical landmark points.The three locations (i.e., distal, middle, and proximal positions) had different displacement amounts. This result indicated that the inner phantom was not moved but deformed. In cases with different phantom settings and marker settings, the ranges of the average TRE were 0.63–15.60 mm (MIM). In cases with different DIR parameters settings, the ranges of the average TRE were as follows: 0.73–7.10 mm (MIM), 8.25–8.66 mm (RayStation), and 8.26–8.43 mm (Velocity). These results suggest that our phantom could evaluate the detailed DIR behaviors with TRE. Therefore, this is indicative of the potential usefulness of our phantom in DIR commissioning and QA.  相似文献   

5.
6.
PurposeDiagnostic positron emission tomography and computed tomography (PET/CT) images can be fused to the planning CT images by a deformable image registration (DIR). The aim of this study was to evaluate the standardized uptake value (SUV) and target delineation on deformed PET images.MethodsWe used a cylindrical phantom and removable inserts of four spheres (16–38 mm in diameter) and three ellipsoids with a volume equal to the 38-mm-diameter sphere (S38) in each. S38 was filled with 18F-fluorodeoxyglucose activity, and then PET/CT images were acquired. The contours of S38 were generated using original PET images by PET auto-segmentation (PET-AS) methods of (1) SUV2.5, (2) 40% of maximum SUV (SUV40%max), and (3) gradient-based (GB), and were deformed to the other inserts by DIR. We compared the volumes and the SUVmax with the generated contours using the deformed PET images.ResultsThe SUVmax was slightly decreased by DIR; the mean absolute difference was −0.10 ± 0.04. For SUV2.5 and SUV40%max, the differences in S38 volumes between the original and deformed PET images were less than 5%, regardless of deformation type. For the GB, the contoured volumes obtained from deformed PET images were larger than those of the original PET images for the deformation type of ellipsoids. When the S38 was deformed to the 16-mm-diameter sphere, the maximum volume difference was −22.8%.ConclusionsAlthough SUV fluctuations by DIR were negligible, the target delineation on deformed PET images by the GB should be carefully considered owing to the distortion of intensity profiles.  相似文献   

7.
PurposeEvaluation of Raystation ANAtomically CONstrained Deformation Algorithm (ANACONDA) performance to different urinary bladder filling levels in male pelvis anatomic site varying the controlling Regions Of Interest (ROIs).MethodsDifferent image datasets were obtained with ImSimQA (Oncology System Limited, Shrewsbury, UK) to evaluate ANACONDA performances (RaySearch Laboratories, Stockholm, Sweden). Deformation vector fields were applied to a synthetic man pelvis and a real patient computed tomography (CT) dataset (reference CTs) resulting in deformed CTs (target CTs) with various bladder filling levels. Different deformable image registrations (DIRs) were generated between each target CTs and reference CTs varying the controlling ROIs subset. Deformed ROIs were mapped from target CT to reference CT and then compared to reference ROIs. Evaluation was performed by Dice Similarity Coefficient (DSC), Correlation Coefficient (CC), Mean Distance to Agreement (MDA), maximum Distance to Agreement (maxDA) and with the introduction of global DSC (global_DSC) and global CC (global_CC) parameters.ResultsIn both synthetic and real patient CT cases, DSC scored less than 0.75 and MDA greater than 3 mm when no ROIs or only bladder were exploited as controlling ROI. DSC and CC increased by increasing the number of controlling ROIs selected whereas, an opposite behavior was observed for MDA and maxDA.ConclusionsANACONDA performances can be influenced by bladder filling fluctuation if no controlling ROIs are selected. Global_DSC and global_CC are useful parameters to quantitatively compare DIR algorithms. DIR performances improve by increasing the number of controlling ROIs selected, reaching a saturation level after a defined ROIs subset selection.  相似文献   

8.
PurposeAn investigation was carried out into the effect of three image registration techniques on the diagnostic image quality of contrast-enhanced magnetic resonance angiography (CE-MRA) images.MethodsWhole-body CE-MRA data from the lower legs of 27 patients recruited onto a study of asymptomatic atherosclerosis were processed using three deformable image registration algorithms. The resultant diagnostic image quality was evaluated qualitatively in a clinical evaluation by four expert observers, and quantitatively by measuring contrast-to-noise ratios and volumes of blood vessels, and assessing the techniques' ability to correct for varying degrees of motion.ResultsThe first registration algorithm (‘AIR’) introduced significant stenosis-mimicking artefacts into the blood vessels' appearance, observed both qualitatively (clinical evaluation) and quantitatively (vessel volume measurements). The two other algorithms (‘Slicer’ and ‘SEMI’), based on the normalised mutual information (NMI) concept and designed specifically to deal with variations in signal intensity as found in contrast-enhanced image data, did not suffer from this serious issue but were rather found to significantly improve the diagnostic image quality both qualitatively and quantitatively, and demonstrated a significantly improved ability to deal with the common problem of patient motion.ConclusionsThis work highlights both the significant benefits to be gained through the use of suitable registration algorithms and the deleterious effects of an inappropriate choice of algorithm for contrast-enhanced MRI data. The maximum benefit was found in the lower legs, where the small arterial vessel diameters and propensity for leg movement during image acquisitions posed considerable problems in making accurate diagnoses from the un-registered images.  相似文献   

9.
Background and AimComputational complexities encountered in craniospinal irradiation (CSI) have been widely investigated with different planning strategies. However, localization of the entire craniospinal axis (CSA) and evaluation of adaptive treatment plans have traditionally been ignored in CSI treatment. In this study, a new strategy for CSI with comprehensive CSA localization and adaptive plan evaluation has been demonstrated using cone beam CT with extended longitudinal field-of-view (CBCTeLFOV).Materials and MethodsMulti-scan CBCT images were acquired with fixed longitudinal table translations (with 1 cm cone-beam overlap) and then fused into a single DICOM-set using the custom software coded in MatLab™. A novel approach for validation of CBCTeLFOV was demonstrated by combined geometry of Catphan-504 and Catphan-604 phantoms. To simulate actual treatment scenarios, at first, the end-to-end workflow of CSI with VMAT was investigated using an anthropomorphic phantom and then applied for two patients (based on random selection).ResultsThe fused CBCTeLFOV images were in excellent agreement with planning CT (pCT). The custom developed software effectively manages spatial misalignments arising out of the uncertainties in treatment/setup geometry. Although the structures mapped from pCT to CBCTeLFOV showed minimal variations, a maximum spatial displacement of up to 1.2 cm (and the mean of 0.8 ± 0.3 cm) was recorded in phantom study. Adaptive plan evaluation of patient paradigms showed the likelihood of under-dosing the craniospinal target.ConclusionOur protocol serves as a guide for precise localization of entire CSA and to ensure adequate dose to the large and complex targets. It can also be adapted for other complex treatment techniques such as total-marrow-irradiation and total-lymphoid-irradiation.  相似文献   

10.
Peptide receptor radionuclide therapy (PRRT) is an effective MRT (molecular radiotherapy) treatment, which consists of multiple administrations of a radiopharmaceutical labelled with 177Lu or 90Y. Through sequential functional imaging a patient specific 3D dosimetry can be derived. Multiple scans should be previously co-registered to allow accurate absorbed dose calculations. The purpose of this study is to evaluate the impact of image registration algorithms on 3D absorbed dose calculation.A cohort of patients was extracted from the database of a clinical trial in PRRT. They were administered with a single administration of 177Lu-DOTATOC. All patients underwent 5 SPECT/CT sequential scans at 1 h, 4 h, 24 h, 40 h, 70 h post-injection that were subsequently registered using rigid and deformable algorithms. A similarity index was calculated to compare rigid and deformable registration algorithms. 3D absorbed dose calculation was carried out with the Raydose Monte Carlo code.The similarity analysis demonstrated the superiority of the deformable registrations (p < .001).Average absorbed dose to the kidneys calculated using rigid image registration was consistently lower than the average absorbed dose calculated using the deformable algorithm (90% of cases), with percentage differences in the range [−19; +4]%. Absorbed dose to lesions were also consistently lower (90% of cases) when calculated with rigid image registration with absorbed dose differences in the range [−67.2; 100.7]%. Deformable image registration had a significant role in calculating 3D absorbed dose to organs or lesions with volumes smaller than 100 mL.Image based 3D dosimetry for 177Lu-DOTATOC PRRT is significantly affected by the type of algorithm used to register sequential SPECT/CT scans.  相似文献   

11.
Based on four dimensional (4D) computed tomography (CT) images, mesh- and binary-based contour propagation algorithms for 4D thoracic radiotherapy treatments were evaluated. Gross tumor volumes (GTVs), lungs, hearts and spinal cords on the CT images at the end-exhale and end-inhale phases for six patients were delineated by the physician. All volumes of interest (VOIs) were automatically propagated from the end-exhale phase to the end-inhale phase using two propagation methods. The propagated VOIs were quantitatively compared with the VOIs contoured at the end-inhale phase by the physician using Dice Similarity Coefficient (DSC), Mean Slicewise Hausdorff Distance (MSHD), Center Of Mass (COM) displacement and volume difference. A two-sided Student’s t test was implemented to examine the significance of the differences between the results obtained from the two algorithms. For GTVs, statistically significant differences between the two algorithms were not observed. For all the other VOIs, the mesh-based method showed higher mean DSCs for the heart, left lung, right lung and spinal cord, lower mean MSHD for the spinal cord, lower mean COM displacement for the heart, and lower mean volume differences for the left lung, right lung and spinal cord with statistically significant differences than the binary-based method. The running time for propagation was approximately 3 s and 3 min for the mesh- and binary-based methods, respectively. Collectively, the mesh-based algorithm provides superiorities in running time and reliability for contour propagation in 4D radiotherapy.  相似文献   

12.
Measurement of static alignment of articulating joints is of clinical benefit and can be determined using image-based registration. We propose a method that could potentially improve the outcome of image-based registration by using initial manual registration. Magnetic resonance images of two wrist specimens were acquired in the relaxed position and during simulated grasp. Transformations were determined from voxel-based image registration between the two volumes. The volumes were manually aligned to match as closely as possible before auto-registration, from which standard transformations were obtained. Then, translation/rotation perturbations were applied to the manual registration to obtain altered initial positions, from which altered auto-registration transformations were obtained. Models of the radiolunate joint were also constructed from the images to simulate joint contact mechanics. We compared the sensitivity of transformations (translations and rotations) and contact mechanics to altering the initial registration condition from the defined standard. We observed that with increasing perturbation, transformation errors appeared to increase and values for contact force and contact area appeared to decrease. Based on these preliminary findings, it appears that the final registration outcome is sensitive to the initial registration.  相似文献   

13.
We evaluated four-dimensional cone beam computed tomography (4D-CBCT) ventilation images (VICBCT) acquired with two different linear accelerator systems at various gantry speeds using a deformable lung phantom.The 4D-CT and 4D-CBCT scans were performed using a computed tomography (CT) scanner, an X-ray volume imaging system (Elekta XVI) mounted in Versa HD, and an On-Board Imager (OBI) system mounted in TrueBeam. Intensity-based deformable image registration (DIR) was performed between peak-exhale and peak-inhale images. VICBCT- and 4D-CT-based ventilation images (VICT) were derived by DIR using two metrics: one based on the Jacobian determinant and one on changes in the Hounsfield unit (HU). Three different DIR regularization values (λ) were used for VICBCT. Correlations between the VICBCT and VICT values were evaluated using voxel-wise Spearman’s rank correlation coefficient (r).In case of both metrics, the Jacobian-based VICBCT with a gantry speed of 0.6 deg/sec in Versa HD showed the highest correlation for all the gantry speeds (e.g., λ = 0.05 and r = 0.68). Thus, the r value of the Jacobian-based VICBCT was greater or equal to that of the HU-based VICBCT. In addition, the ventilation accuracy of VICBCT increased at low gantry speeds.Thus, the image quality of VICBCT was affected by the change in gantry speed in both the imaging systems. Additionally, DIR regularization considerably influenced VICBCT in both the imaging systems. Our results have the potential to assist in designing CBCT protocols, incorporating VICBCT imaging into the functional avoidance planning process.  相似文献   

14.
15.
We evaluate the non-linear characteristics of the human lung via image registration-derived local variables based on volumetric multi-detector-row computed tomographic (MDCT) lung image data of six normal human subjects acquired at three inflation levels: 20% of vital capacity (VC), 60% VC and 80% VC. Local variables include Jacobian (ratio of volume change) and maximum shear strain for assessment of lung deformation, and air volume change for assessment of air distribution. First, the variables linearly interpolated between 20% and 80% VC images to reflect deformation from 20% to 60% VC are compared with those of direct registration of 20% and 60% VC images. The result shows that the linearly-interpolated variables agree only qualitatively with those of registration (P<0.05). Then, a quadratic (or linear) interpolation is introduced to link local variables to global air volumes of three images (or 20% and 80% VC images). A sinusoidal breathing waveform is assumed for assessing the time rate of change of these variables. The results show significant differences between two-image and three-image results (P<0.05). The three-image results for the whole lung indicate that the peak of the maximum shear rate occurs at about 37% of the maximum volume difference between 20% and 80% VC, while the peaks for the Jacobian and flow rate occur at 50%. This is in agreement with accepted physiology whereby lung tissues deform more at lower lung volumes due to lower elasticity and greater compliance. Furthermore, the three-image results show that the upper and middle lobes, even in the recumbent, supine posture, reach full expansion earlier than the lower lobes.  相似文献   

16.
Rationale and objectivesDedicated breast CT and PET/CT scanners provide detailed 3D anatomical and functional imaging data sets and are currently being investigated for applications in breast cancer management such as diagnosis, monitoring response to therapy and radiation therapy planning. Our objective was to evaluate the performance of the diffeomorphic demons (DD) non-rigid image registration method to spatially align 3D serial (pre- and post-contrast) dedicated breast computed tomography (CT), and longitudinally-acquired dedicated 3D breast CT and positron emission tomography (PET)/CT images.MethodsThe algorithmic parameters of the DD method were optimized for the alignment of dedicated breast CT images using training data and fixed. The performance of the method for image alignment was quantitatively evaluated using three separate data sets; (1) serial breast CT pre- and post-contrast images of 20 women, (2) breast CT images of 20 women acquired before and after repositioning the subject on the scanner, and (3) dedicated breast PET/CT images of 7 women undergoing neo-adjuvant chemotherapy acquired pre-treatment and after 1 cycle of therapy.ResultsThe DD registration method outperformed no registration (p < 0.001) and conventional affine registration (p ≤ 0.002) for serial and longitudinal breast CT and PET/CT image alignment. In spite of the large size of the imaging data, the computational cost of the DD method was found to be reasonable (3–5 min).ConclusionsCo-registration of dedicated breast CT and PET/CT images can be performed rapidly and reliably using the DD method. This is the first study evaluating the DD registration method for the alignment of dedicated breast CT and PET/CT images.  相似文献   

17.
ObjectiveInvestigating the application of CT images when diagnosing lung cancer based on finite mixture model is the objective. Method: 120 clean healthy rats were taken as the research objects to establish lung cancer rat model and carry out lung CT image examination. After the successful CT image data preprocessing, the image is segmented by different methods, which include lung nodule segmentation on the basis of Adaptive Particle Swarm Optimization – Gaussian mixture model (APSO-GMM), lung nodule segmentation on the basis of Adaptive Particle Swarm Optimization – gamma mixture model (APSO-GaMM), lung nodule segmentation based on statistical information and self-selected mixed distribution model, and lung nodule segmentation based on neighborhood information and self-selected mixed distribution model. The segmentation effect is evaluated. Results: Compared with the results of lung nodule segmentation based on statistical information and self-selected mixed distribution model, the Dice coefficient of lung nodule segmentation based on neighborhood information and self-selected mixed distribution model is higher, the relative final measurement accuracy is smaller, the segmentation is more accurate, but the running time is longer. Compared with APSO-GMM and APSO-GaMM, the dice value of self-selected mixed distribution model segmentation method is larger, and the final measurement accuracy is smaller. Conclusion: Among the five methods, the dice value of the self-selected mixed distribution model based on neighborhood information is the largest, and the relative accuracy of the final measurement is the smallest, indicating that the segmentation effect of the self-selected mixed distribution model based on neighborhood information is the best.  相似文献   

18.
State‐of‐the‐art image‐processing methods offer new possibilities for diagnosing diseases using scattered light. The optical diagnosis of rheumatism is taken as an example to show that the diagnostic sensitivity can be improved using overlapped pseudocolored images of different wavelengths, provided that multispectral images are recorded to compensate for any motion‐related artefacts that occur during examination. (© 2010 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

19.
Background and purposeThe use of cone beam computed tomography (CBCT) for performing dose calculations in radiation therapy has been widely investigated as it could provide a quantitative analysis of the dosimetric impact of changes in patients during the treatment. The aim of this review was to classify different techniques adopted to perform CBCT dose calculation and to report their dosimetric accuracy with respect to the metrics used.Methods and materialsA literature search was carried out in PubMed and ScienceDirect databases, based upon the following keywords: “cone beam computed tomography”, “CBCT”, “cone beam CT”, “dose calculation”, “accuracy”. Sixty-nine peer-reviewed relevant articles were included in this review: thirty-one patient studies, fifteen phantom studies and twenty-three patient & phantom studies. Most studies were found to have focused on head and neck, lung and prostate cancers.ResultsThe techniques adopted to perform CBCT dose calculation have been grouped in six categories labelled as (1) pCT calibration, (2) CBCT calibration, (3) HU override, (4) Deformable image registration, (5) Dose deformation, and (6) Combined techniques. Differences between CBCT dose and reference dose were reported both for target volumes and OARs.ConclusionsA comparison among the available techniques for CBCT dose calculations is challenging as many variables are involved. Therefore, a set of reporting standards is recommended to enable meaningful comparisons among different studies. The accuracy of the results was strongly dependent on the image quality, regardless of the methods used, highlighting the need for dose validation and quality assurance standards.  相似文献   

20.
AimDescribe the anatomical changes and tumor displacement due to a rapid response of a patient’s small cell lung cancer (SCLC) during definitive chemoradiotherapy (CRT).BackgroundThe treatment for SCLC is based on CRT. If interfractional changes during RT are incorrectly assessed they might compromise adequate coverage of the tumor or increase dose to organs at risk. Image guided RT with cone-beam computed tomography (CBCT) allows to identify daily treatment variations.Material and methodsDescribe a SCLC case with rapid changes in size, shape and location of the primary tumor during RT.Case reportA 62-year-old woman was diagnosed with SCLC with complete obstruction of the anterior and lingular bronchi and incomplete left thorax expansion due to a 12 × 15 cm mass. During CRT (45 Gy in 1.5 Gy per fraction, twice daily) the patient presented rapid tumor response, leading to resolution of bronchi obstruction and hemithorax expansion. Tumor shifted up to 4 cm from its original position. The identification of variations led to two new simulations and planning in a 3-week treatment course.ConclusionsThe complete radiological response was possible due to systematic monitoring of the tumor during CRT. We recommend frequent on-site image verification. Daily CBCT should be considered with pretreatment tumor obstruction, pleural effusion, atelectasis, large volumes or radiosensitive histology that might resolve early and rapidly and could lead to a miss of the tumor or increased toxicity. Further research should be made in replanning effect in coverage of microscopic disease since it increases uncertainty in this scenario.  相似文献   