 共查询到20条相似文献,搜索用时 46 毫秒
1.
PurposeTo assess the quality of images obtained on a dual energy computed tomography (CT) scanner.MethodsImage quality was assessed on a 64 detector-row fast kVp-switching dual energy CT scanner (Revolution GSI, GE Medical Systems). The Catphan phantom and a low contrast resolution phantom were employed. Acquisitions were performed at eight different radiation dose levels that ranged from 9 mGy to 32 mGy. Virtual monochromatic spectral images (VMI) were reconstructed in the 40–140 keV range using all available kernels and iterative reconstruction (IR) at four different blending levels. Modulation Transfer Function (MTF) curves, image noise, image contrast, noise power spectrum and contrast to noise ratio were assessed.ResultsIn-plane spatial resolution at the 10% of the MTF curve was 0.60 mm−1. In-plane spatial resolution was not modified with VMI energy and IR blending level. Image noise was reduced from 16.6 at 9 mGy to 6.7 at 32 mGy, while peak frequency remained within 0.14 ± 0.01 mm−1. Image noise was reduced from 14.3 at IR 10% to 11.5 at IR 50% at a constant peak frequency. The lowest image noise and maximum peak frequency were recorded at 70 keV.ConclusionsOur results have shown how objective image quality is varied when different levels of radiation dose and different settings in IR are applied. These results provide CT operators an in depth understanding of the imaging performance characteristics in dual energy CT.  相似文献   

2.
3.
PurposeFlattening filter free (FFF) beams are increasingly being considered for stereotactic radiotherapy (SRT). For the first time, the performance of a monolithic silicon array detector under 6 and 10 MV FFF beams was evaluated. The dosimeter, named “Octa” and designed by the Centre for Medical Radiation Physics (CMRP), was tested also under flattened beams for comparison.MethodsOutput factors (OFs), percentage depth-dose (PDD), dose profiles (DPs) and dose per pulse (DPP) dependence were investigated. Results were benchmarked against commercially available detectors for small field dosimetry.ResultsThe dosimeter was shown to be a ‘correction-free’ silicon array detector for OFs and PDD measurements for all the beam qualities investigated. Measured OFs were accurate within 3% and PDD values within 2% compared against the benchmarks. Cross-plane, in-plane and diagonal DPs were measured simultaneously with high spatial resolution (0.3 mm) and real time read-out. A DPP dependence (24% at 0.021 mGy/pulse relative to 0.278 mGy/pulse) was found and could be easily corrected for in the case of machine specific quality assurance applications.ConclusionsResults were consistent with those for monolithic silicon array detectors designed by the CMRP and previously characterized under flattened beams only, supporting the robustness of this technology for relative dosimetry for a wide range of beam qualities and dose per pulses. In contrast to its predecessors, the design of the Octa offers an exhaustive high-resolution 2D dose map characterization, making it a unique real-time radiation detector for small field dosimetry for field sizes up to 3 cm side.  相似文献   

4.
PurposeThe diagnostic reference level (DRL) has been established to optimize the diagnostic methods and reduce radiation dose during radiographic examinations. The aim of this study was to present a completely new solution based on Cloud-Fog software architecture for automatic establishment of the DRL values during dental cone-beam computed tomography (CBCT) according to digital imaging and communications in medicine (DICOM) structured reports.Methods and MaterialsA Cloud-Fog software architecture was used for automatic data handling. This architecture used the DICOM structured reports as a source for extracting the required information by fog devices in the imaging center. These devices transferred the derived information to the cloud server. The cloud server calculated the value of indication-based DRL in dental CBCT imaging based upon the parameters and adequate quantities of the absorbed dose. The feedback of DRL value was continuously announced to the imaging centers in 6 phases. In each phase, the level of the dose was optimized in imaging centers.ResultsThe DRL value was established for 5-specific indications, including third molar teeth (511 mGy.cm2), implant (719 mGy.cm2), form and position anomalies of the tooth (408 mGy.cm2), dentoalveolar pathologies (612 mGy.cm2), and endodontics (632 mGy.cm2). The determination of the DRL value in each phase revealed a downward trend until stabilization.ConclusionThe new solution presented in this study makes it possible to calculate and update the DRL value nationally and automatically among all centers. Also, the results showed that this approach is successful in establishing stabilized DRL values.  相似文献   

5.
6.
PurposeThe purpose of our study was to acquire dose profiles at critical organs of lung and breast regions using optically stimulated luminescence (OSL) dosimeters; assess the actual radiation dose delivered at retrospective and prospective computed tomography coronary angiography (CTCA).Materials and methodsUsing a chest CT phantom we applied a prospectively-gated step-and-shoot- and a retrospectively-gated helical mode on a 64-detector row CT scanner. Retrospective scan mode was used with and without electrocardiogram (ECG) based tube current modulation. OSL dosimeters were used to measure dose profiles. In the both scan modes we acquired dose profiles and determined the mean and maximum dose in left lung and in left breast regions.ResultsIn prospective mode, the mean dose was 21.53 mGy in left lung- and 23.59 mGy in left breast region. With respect to the retrospective mode, the mean dose with tube current modulation was 38.63 mGy for left lung- and 46.02 mGy for left breast region, i.e. 0.56 and 0.55 times lower than the mean dose without modulation.ConclusionThe OSL dosimeter is useful for measurement of the actual radiation dose along z-axis at lung and breast regions in the prospective and the retrospective CTCA.  相似文献   

7.
Abstract

The experimental objectives were to verify whether a qualitative measure of creep feed consumption using a dye was related to performance, and associate this with teat order. Indigo carmine (5 g/kg) was added to a starter diet between days 12 and 31 (weaning) of lactation. On days 19, 23, 27 and 31, faeces from each piglet were assessed for colouration. Each piglet was categorized as a ‘good’, ‘moderate’ or ‘small/non’ eater of feed. There were no differences in pre-weaning growth rate between categories. Piglets classed as ‘good’ or ‘moderate’ eaters in lactation grew fastest (p = 0.009) in the first three days after weaning, but between days 4 and 7, the highest growth rate occurred in ‘moderate’ eaters. ‘Small/non' eaters grew slower (p < 0.01) between weaning and 28 days after weaning. Piglets drinking milk from anterior teats were heavier at weaning (p < 0.001) and for the first 14 days after weaning (p = 0.104) compared to piglets sucking posterior teats. Data from this study demonstrated that creep feed intake of piglets could qualitatively be assessed using indigo carmine, and that this categorization was related to performance in the immediate post-weaning period.  相似文献   

8.
The construction of microbial platform organisms by means of genome reduction is an ongoing topic in biotechnology. In this study, we investigated whether the deletion of single or multiple gene clusters has a positive effect on the secretion of cutinase from Fusarium solani pisi in the industrial workhorse Corynebacterium glutamicum. A total of 22 genome-reduced strain variants were compared applying two Sec signal peptides from Bacillus subtilis. High-throughput phenotyping using robotics-integrated microbioreactor technology with automated harvesting revealed distinct cutinase secretion performance for a specific combination of signal peptide and genomic deletions. The biomass-specific cutinase yield for strain GRS41_51_NprE was increased by ~ 200%, although the growth rate was reduced by ~ 60%. Importantly, the causative deletions of genomic clusters cg2801-cg2828 and rrnC-cg3298 could not have been inferred a priori. Strikingly, bioreactor fed-batch cultivations at controlled growth rates resulted in a complete reversal of the screening results, with the cutinase yield for strain GRS41_51_NprE dropping by ~ 25% compared to the reference strain. Thus, the choice of bioprocess conditions may turn a ‘high-performance’ strain from batch screening into a ‘low-performance’ strain in fed-batch cultivation. In conclusion, future studies are needed in order to understand metabolic adaptations of C. glutamicum to both genomic deletions and different bioprocess conditions.  相似文献   

9.
Pseudomonas fluorescens strains PRS9 and GRS1 (wild type) were made mercury resistant PRS9Hg(r) (147 microM HgCl2) and GRS1Hg(r) (55 microM HgCl2), respectively, in King's medium by enrichment selection and their in situ root colonization studies were carried out. Mercury resistant mutant of PRS9 was stable and resulted in significant increase in root and shoot fresh weight (P < 0.05). Both the mutants are positive for indoleacetic acid (IAA), 'P' solubilization and siderophore production. PRS9, potent 'P' solubilizer, exhibited higher 'P' solubilization as compared to GRS1. After 2 weeks of inoculation, the population level of wild type PRS9 and its mercury resistant mutants has increased (50 fold). Mercury resistance has no adverse effect on the growth promoting properties of mutants besides being comparable in its morphological and physiological properties with their wild type counterpart. Furthermore, mercury resistant character facilitates rhizospheric competition and thus helpful for establishment of growth promoting strains where metal ions are either limiting and/or present at toxic level.  相似文献   

10.
目的:探讨能谱CT优化胃肿瘤扫描辐射剂量对肾上腺嗜铬细胞瘤的诊断价值。方法:采用回顾性、抽样、随机研究方法选择2012年9月到2017年2月在我院诊治的肾上腺嗜铬细胞瘤患者59例作为研究对象,所有患者都给予常规CT扫描与能谱CT优化胃肿瘤扫描,记录和比较辐射剂量与图像质量。结果:所有病例包膜均完整,边缘清楚,肿瘤内见单发或多发低密度区,肿瘤实质区呈不均匀显著强化。常规CT与能谱CT的图像质量主观评分分别为3.89±0.45分和4.54±0.34分;常规CT与能谱CT图像的胃肿瘤CT值分别为31.94±6.39HU和35.29±5.19HU,对比都有显著差异(P0.05)。能谱CT图像的膀胱和皮下脂肪图像噪声值都显著低于常规CT图像,对比差异都有统计学意义(P0.05);能谱CT扫描的CTDIvol和DLP分别为12.39±3.48mGy和624.10±39.19mGy.cm,都显著低于常规CT扫描的14.09±4.13mGy和653.92±56.29mGy.cm(P0.05)。结论:能谱CT优化胃肿瘤扫描在肾上腺嗜铬细胞瘤诊断中的应用能有效减少辐射剂量与图像噪声,提高图像CT值与主观质量,临床应用价值更高。  相似文献   

11.
PurposeTo estimate the organ-specific probability for carcinogenesis following radiotherapy for non-malignant shoulder syndrome.MethodsPhoton-beam radiation therapy to 6 Gy for shoulder syndrome was simulated with a Monte Carlo code. An androgynous computational phantom representing a typical adult was used to calculate the radiation dose to out-of-field organs having a predilection for carcinogenesis. The organ-specific lifetime attributable risk (LAR) for out-of-field cancer induction was estimated by the organ dose calculations and the proper risk factors introduced by the BEIR-VII report. The average dose (Dav) and organ equivalent dose (OED) of lung, which was partially included within the treatment volume, was found from 3d-conformal radiotherapy plans. The Dav and OED were used to estimate the lung cancer risk with a linear and mechanistic models, respectively. All risk assessments were made for 50- and 60-year-old male and female patients.ResultsMonte Carlo simulations resulted in an out-of-field organ dose range of 0.7–48.4 mGy. The LARs for out-of-field cancer induction were (1.4 × 10−4)% to (2.8 × 10−2)%. These probabilities were at least 403 times lower than the respective lifetime intrinsic risk (LIR) values. The Dav and OED of lung was up to 164.9 and 142.3 mGy, respectively. The LAR for developing lung malignancies varied from 0.11 to 0.18% by the model used and the patient’s age and gender. The lung cancer risks were 36–64 times smaller than the LIRs.ConclusionsThe estimated probabilities for developing malignancies due to radiotherapy for non-malignant shoulder syndrome are minor relative to the natural cancer occurrence rates.  相似文献   

12.
PurposeTo compare abdominal imaging dose from 3D imaging in radiology (standard/low-dose/dual-energy CT) and radiotherapy (planning CT, kV cone-beam CT (CBCT)).MethodsDose was measured by thermoluminescent dosimeters (TLD’s) placed at 86 positions in an anthropomorphic phantom. Point, organ and effective dose were assessed, and secondary cancer risk from imaging was estimated.ResultsOverall dose and mean organ dose comparisons yield significantly lower dose for the optimized radiology protocols (dual-source and care kV), with an average dose of 0.34±0.01 mGy and 0.54±0.01 mGy (average ± standard deviation), respectively. Standard abdominal CT and planning CT involve considerably higher dose (13.58 ± 0.18 mGy and 18.78±0.27 mGy, respectively). The CBCT dose show a dose fall-off near the field edges. On average, dose is reduced as compared with the planning or standard CT (3.79 ± 0.21 mGy for 220° rotation and 7.76 ± 0.37 mGy for 360°), unless the high-quality setting is chosen (20.30 ± 0.96 mGy). The mean organ doses show a similar behavior, which translates to the estimated secondary cancer risk. The modelled risk is in the range between 0.4 cases per million patient years (PY) for the radiological scans dual-energy and care kV, and 300 cases per million PY for the high-quality CBCT setting.ConclusionsModern radiotherapy imaging techniques (while much lower in dose than radiotherapy), involve considerably more dose to the patient than modern radiology techniques. Given the frequency of radiotherapy imaging, a further reduction in radiotherapy imaging dose appears to be both desirable and technically feasible.  相似文献   

13.
PurposeTo investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses.Materials and methodsUsing an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70–80%, 40–80%, and 0–100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center.ResultsWith half-scan reconstruction at 60 bpm, a 70–80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70–80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm.ConclusionAEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose.  相似文献   

14.
Abstract

The performance of a supercomputer installation (Cray-IS with Amdahl front-end) is compared with a ‘desk-top’ computer (IBM PC-AT with 80287 Numeric Data Processor) using both execution time and total job turnaround time for a set of benchmark programs which includes a Monte Carlo simulation. The effect of compiler efficiency and optimisation for system-specific hardware on execution time are discusssed. We propose the use of ‘turn-around time’ as a criterion for computer system performance, and show that judged by this criterion, ‘desk-top’ computing can provide a significant fraction of the power of a networked supercomputer installation.  相似文献   

15.
PurposeWe used pediatric and adult anthropomorphic phantoms to compare the radiation dose of low- and standard tube voltage chest and abdominal non-contrast-enhanced computed tomography (CT) scans. We also discuss the optimal low tube voltage for non-contrast-enhanced CT.MethodsUsing a female adult- and three differently-sized pediatric anthropomorphic phantoms we acquired chest and abdominal non-contrast-enhanced scans on a 320-multidetector CT volume scanner. The tube voltage was set at 80-, 100-, and 120 kVp. The tube current was automatically assigned on the CT scanner in response to the set image noise level. On each phantom and at each tube voltage we measured the surface and center dose using high-sensitivity metal-oxide-semiconductor field-effect transistor detectors.ResultsThe mean surface dose of chest and abdominal CT scans in 5-year olds was 4.4 and 5.3 mGy at 80 kVp, 4.5 and 5.4 mGy at 100 kV, and 4.0 and 5.0 mGy at 120 kVp, respectively. These values were similar in our 3-pediatric phantoms (p > 0.05). The mean surface dose in the adult phantom increased from 14.7 to 19.4 mGy for chest- and from 18.7 to 24.8 mGy for abdominal CT as the tube voltage decreased from 120 to 80 kVp (p < 0.01).ConclusionCompared to adults, the surface and center dose for pediatric patients is almost the same despite a decrease in the tube voltage and the low tube voltage technique can be used for non-contrast-enhanced chest- and abdominal scanning.  相似文献   

16.
PurposeMost radiation protection programs, regulations and guidance apply specific restrictions to the occupational exposure of pregnant workers. The aim of this study was to compile data from the declared pregnant woman (DPW) radiation protection program over more than 5 years at a large, high-volume, comprehensive oncology academic/medical institution and to evaluate for effectiveness against existing regulations and guidance.MethodsA retrospective review was performed of the data collected as part of the DPW radiation protection program from January 2010 through May 2016, including the number of declared pregnancies, worker category, personal and fetal dosimetry monitoring measurements, workplace modifications, as well as the monthly and total recorded badge results during the entire pregnancy.Results245 pregnancies were declared. The mean monthly fetal radiation dosimetry result was 0.009 mSv with a median of 0.005 mSv and a maximum of 0.39 mSv. The mean total dose over the entire pregnancy was estimated to be 0.08 mSv with a median of 0.05 mSv and a maximum of 0.89 mSv. Only 8 (3.2%) of the 245 declared pregnancies required that workplace modifications be implemented for the worker.ConclusionsThe implementation of a declared pregnancy and fetal assessment program, careful planning, an understanding of the risks, and minimization of radiation dose by employing appropriate radiation safety measures as needed, can allow medical staff to perform procedures and normal activities without incurring significant risks to the conceptus, or significant interruptions of job activities for most medical workers.  相似文献   

17.
BackgroundType 2 diabetes (T2D) is highly prevalent in British South Asians, yet they are underrepresented in research. Genes & Health (G&H) is a large, population study of British Pakistanis and Bangladeshis (BPB) comprising genomic and routine health data. We assessed the extent to which genetic risk for T2D is shared between BPB and European populations (EUR). We then investigated whether the integration of a polygenic risk score (PRS) for T2D with an existing risk tool (QDiabetes) could improve prediction of incident disease and the characterisation of disease subtypes.Methods and findingsIn this observational cohort study, we assessed whether common genetic loci associated with T2D in EUR individuals were replicated in 22,490 BPB individuals in G&H. We replicated fewer loci in G&H (n = 76/338, 22%) than would be expected given power if all EUR-ascertained loci were transferable (n = 101, 30%; p = 0.001). Of the 27 transferable loci that were powered to interrogate this, only 9 showed evidence of shared causal variants. We constructed a T2D PRS and combined it with a clinical risk instrument (QDiabetes) in a novel, integrated risk tool (IRT) to assess risk of incident diabetes. To assess model performance, we compared categorical net reclassification index (NRI) versus QDiabetes alone. In 13,648 patients free from T2D followed up for 10 years, NRI was 3.2% for IRT versus QDiabetes (95% confidence interval (CI): 2.0% to 4.4%). IRT performed best in reclassification of individuals aged less than 40 years deemed low risk by QDiabetes alone (NRI 5.6%, 95% CI 3.6% to 7.6%), who tended to be free from comorbidities and slim. After adjustment for QDiabetes score, PRS was independently associated with progression to T2D after gestational diabetes (hazard ratio (HR) per SD of PRS 1.23, 95% CI 1.05 to 1.42, p = 0.028). Using cluster analysis of clinical features at diabetes diagnosis, we replicated previously reported disease subgroups, including Mild Age-Related, Mild Obesity-related, and Insulin-Resistant Diabetes, and showed that PRS distribution differs between subgroups (p = 0.002). Integrating PRS in this cluster analysis revealed a Probable Severe Insulin Deficient Diabetes (pSIDD) subgroup, despite the absence of clinical measures of insulin secretion or resistance. We also observed differences in rates of progression to micro- and macrovascular complications between subgroups after adjustment for confounders. Study limitations include the absence of an external replication cohort and the potential biases arising from missing or incorrect routine health data.ConclusionsOur analysis of the transferability of T2D loci between EUR and BPB indicates the need for larger, multiancestry studies to better characterise the genetic contribution to disease and its varied aetiology. We show that a T2D PRS optimised for this high-risk BPB population has potential clinical application in BPB, improving the identification of T2D risk (especially in the young) on top of an established clinical risk algorithm and aiding identification of subgroups at diagnosis, which may help future efforts to stratify care and treatment of the disease.

Sam Hodgson and colleagues investigate whether the common genetic differences associated with type 2 diabetes in people of European ancestry can be transferred to people of British Pakistani and Bangladeshi ancestry, integrating a novel polygenic risk score with an established clinical risk score.  相似文献   

18.
ABSTRACT

Introduction: Due to the relatively low mutation rate and high frequency of copy number variation, finding actionable genetic drivers of high-grade serous carcinoma (HGSC) is a challenging task. Furthermore, emerging studies show that genetic alterations are frequently poorly represented at the protein level adding a layer of complexity. With improvements in large-scale proteomic technologies, proteomics studies have the potential to provide robust analysis of the pathways driving high HGSC behavior.

Areas covered: This review summarizes recent large-scale proteomics findings across adequately sized ovarian cancer sample sets. Key words combined with ‘ovarian cancer’ including ‘proteomics’, ‘proteogenomic’, ‘reverse-phase protein array’, ‘mass spectrometry’, and ‘adaptive response’, were used to search PubMed.

Expert opinion: Proteomics analysis of HGSC as well as their adaptive responses to therapy can uncover new therapeutic liabilities, which can reduce the emergence of drug resistance and potentially improve patient outcomes. There is a pressing need to better understand how the genomic and epigenomic heterogeneity intrinsic to ovarian cancer is reflected at the protein level and how this information could be used to improve patient outcomes.  相似文献   

19.
BackgroundCurrently, CBCT system is an indispensable component of radiation therapy units. Because of that, it is important in treatment planning and diagnosis. CBCT is also an crucial tool for patient positioning and verification in image-guided radiation therapy (IGRT). Therefore, it is critical to investigate the patient organ doses arising from CBCT imaging. The purpose of this study is to evaluate patient organ doses and effective dose to patients from three different protocols of Elekta Synergy XVI system for kV CBCT imaging examinations in image guided radiation therapy.Materials and methodsOrgan dose measurements were done with thermoluminescent dosimeters in Alderson RA NDO male phantom for head & neck (H&N), chest and pelvis protocols of the Elekta Synergy XVI kV CBCT system. From the measured organ dose, effective dose to patients were calculated according to the International Commission on Radiological Protection 103 report recommendations.ResultsFor H&N, chest and pelvis scans, the organ doses were in the range of 0.03–3.43 mGy, 6.04–22.94 mGy and 2.5–25.28 mGy, respectively. The calculated effective doses were 0.25 mSv, 5.56 mSv and 4.72 mSv, respectively.ConclusionThe obtained results were consistent with the most published studies in the literature. Although the doses to patient organs from the kV CBCT system were relatively low when compared with the prescribed treatment dose, the amount of delivered dose should be monitored and recorded carefully in order to avoid secondary cancer risk, especially in pediatric examinations.  相似文献   

20.
PurposeTo establish diagnostic reference levels (DRLs) and achievable levels (ALs) for the most common fluoroscopically guided interventions (FGIs) performed in operating rooms using mobile C-arm equipment.MethodsA national survey was performed in 57 centers in France. Anonymous data from 6817 patients undergoing FGIs were prospectively collected over a period of 7 months. DRLs (third quartile of the distribution) and ALs (median of the distribution) were determined for each type of intervention in terms of kerma area product (KAP) and fluoroscopy time (FT).ResultsDRLs and ALs were proposed for 31 procedure types related to seven surgical specialties: orthopedics (n = 9), urology (n = 3), vascular (n = 6), cardiology (n = 5), neurosurgery (n = 3), gastrointestinal (n = 3), and multi-specialty (n = 2). DRLs in terms of KAP ranged from 0.1 Gy·cm2 for hallux valgus to 78 Gy·cm2 for abdominal aortic aneurysm endovascular repair. A factor of 155 was obtained between the FTs for a herniated lumbar disk (0.2 min) and an abdominal aortic aneurysm endovascular repair (31 min). The highest variations were obtained within orthopedic procedures in terms of KAP (ratio 122) and within gastrointestinal procedures in terms of FT (ratio 9). Overall, the FGIs associated with the highest radiation exposure (KAP > 10 Gy·cm2) were found in the cardiology, vascular, and gastrointestinal specialties.ConclusionsDRLs and ALs are suggested for a wide range of FGIs performed in operating rooms using a mobile C-arm. We aim at providing a practical optimization tool for medical physicists and surgeons.  相似文献   