共查询到20条相似文献,搜索用时 15 毫秒
1.
Total internal reflection-fluorescence correlation spectroscopy (TIR-FCS) is an emerging technique that is used to measure events at or near an interface, including local fluorophore concentrations, local translational mobilities and the kinetic rate constants that describe the association and dissociation of fluorophores at the interface. TIR-FCS is also an extremely promising method for studying dynamics at or near the basal membranes of living cells. This protocol gives a general overview of the steps necessary to construct and test a TIR-FCS system using either through-prism or through-objective internal reflection geometry adapted for FCS. The expected forms of the autocorrelation function are discussed for the cases in which fluorescent molecules in solution diffuse through the depth of the evanescent field, but do not bind to the surface of interest, and in which reversible binding to the surface also occurs. 相似文献
2.
Total internal reflection with fluorescence correlation spectroscopy: combined surface reaction and solution diffusion 下载免费PDF全文
Total internal reflection with fluorescence correlation spectroscopy (TIR-FCS) is a method for measuring the surface association/dissociation rates and absolute densities of fluorescent molecules at the interface of solution and a planar substrate. This method can also report the apparent diffusion coefficient and absolute concentration of fluorescent molecules very close to the surface. An expression for the fluorescence fluctuation autocorrelation function in the absence of contributions from diffusion through the evanescent wave, in solution, has been published previously (N. L. Thompson, T. P. Burghardt, and D. Axelrod. 1981, Biophys. J. 33:435-454). This work describes the nature of the TIR-FCS autocorrelation function when both surface association/dissociation kinetics and diffusion through the evanescent wave contribute to the fluorescence fluctuations. The fluorescence fluctuation autocorrelation function depends in general on the kinetic association and dissociation rate constants, the surface site density, the concentration of fluorescent molecules in solution, the solution diffusion coefficient, and the depth of the evanescent field. Both general and approximate expressions are presented. 相似文献
3.
Total internal reflection with fluorescence correlation spectroscopy: nonfluorescent competitors 下载免费PDF全文
Total internal reflection with fluorescence correlation spectroscopy is a method for measuring the surface association/dissociation rate constants and absolute densities of fluorescent molecules at the interface of a planar substrate and solution. This method can also report the apparent diffusion coefficient and absolute concentration of fluorescent molecules very close to the surface. Theoretical expressions for the fluorescence fluctuation autocorrelation function when both surface association/dissociation kinetics and diffusion through the evanescent wave, in solution, contribute to the fluorescence fluctuations have been published previously. In the work described here, the nature of the autocorrelation function when both surface association/dissociation kinetics and diffusion through the evanescent wave contribute to the fluorescence fluctuations, and when fluorescent and nonfluorescent molecules compete for surface binding sites, is described. The autocorrelation function depends in general on the kinetic association and dissociation rate constants of the fluorescent and nonfluorescent molecules, the surface site density, the concentrations of fluorescent and nonfluorescent molecules in solution, the solution diffusion coefficients of the two chemical species, the depth of the evanescent field, and the size of the observed area on the surface. Both general and approximate expressions are presented. 相似文献
4.
In this paper, the conceptual basis and experimental design of total internal reflection with fluorescence correlation spectroscopy (TIR-FCS) is described. The few applications to date of TIR-FCS to supported membranes are discussed, in addition to a variety of applications not directly involving supported membranes. Methods related, but not technically equivalent, to TIR-FCS are also summarized. Future directions for TIR-FCS are outlined. 相似文献
5.
We have modeled the structure of KirBac1.1 in an open state using as a starting point the structure of KirBac1.1 in its closed conformation (Protein Data Bank 1P7B). To test the validity of the open-state model, molecular dynamics simulations in octane, a lipid bilayer mimetic, were carried out. Simulations of the closed conformer were used for comparison purposes. The total simulation time was approximately 138 ns. The initial open model was refined by using projection maps obtained from electron microscopy experiments on two-dimensional crystals of the inwardly rectifying K+ channel KirBac3.1 from Magentospirillum magnetotacticum captured in its open state (C. Vénien-Bryan, unpublished data). Significant movements of the outer helices take place in going from the closed to the open model in agreement with structural and biochemical data in potassium channels, which suggests that gating is accomplished by a conformational change that takes place in the transmembrane domain upon an external stimulus. The motion of the inner helices is mainly achieved by bending at conserved glycine residues that have been previously reported to act as molecular hinges. Overall, these simulations suggest that the open conformer is stable, providing a plausible all-atom model that will enable the study of potential gating mechanisms in more detail. 相似文献
6.
Ligand-receptor kinetics measured by total internal reflection with fluorescence correlation spectroscopy 下载免费PDF全文
Total internal reflection excitation used in combination with fluorescence correlation spectroscopy (TIR-FCS) is a method for characterizing the dynamic behavior and absolute concentrations of fluorescent molecules near or at the interface of a planar substrate and a solution. In this work, we demonstrate for the first time the use of TIR-FCS for examining the interaction kinetics of fluorescent ligands in solution which specifically and reversibly associate with receptors in substrate-supported planar membranes. Fluorescence fluctuation autocorrelation functions were obtained for a fluorescently labeled IgG reversibly associating with the mouse receptor FcgammaRII, which was purified and reconstituted into substrate-supported planar membranes. Data were obtained as a function of the IgG solution concentration, the Fc receptor surface density, the observation area size, and the incident intensity. Best fits of the autocorrelation functions to appropriate theoretical forms gave measures of the average surface density of bound IgG, the local solution concentration of IgG, the kinetic rate constant for surface dissociation, and the rate of diffusion through the depth of the evanescent field. The average number of observed fluorescent molecules, both in solution and bound to the surface, scaled with the solution concentration of IgG, observation area size, and Fc receptor surface density as expected. The dissociation rate constant and rate of diffusion through the evanescent field agree with previous results, and all measured parameters were independent of the incident intensity. 相似文献
7.
Immunoglobulin surface-binding kinetics studied by total internal reflection with fluorescence correlation spectroscopy. 总被引:5,自引:3,他引:2 下载免费PDF全文
An experimental application of total internal reflection with fluorescence correlation spectroscopy (TIR/FCS) is presented. TIR/FCS is a new technique for measuring the binding and unbinding rates and surface diffusion coefficient of fluorescent-labeled solute molecules in equilibrium at a surface. A laser beam totally internally reflects at the solid-liquid interface, selectively exciting surface-adsorbed molecules. Fluorescence collected by a microscope from a small, well-defined surface area approximately 5 micron2 spontaneously fluctuates as solute molecules randomly bind to, unbind from, and/or diffuse along the surface in chemical equilibrium. The fluorescence is detected by a photomultiplier and autocorrelated on-line by a minicomputer. The shape of the autocorrelation function depends on the bulk and surface diffusion coefficients, the binding rate constants, and the shape of the illuminated and observed region. The normalized amplitude of the autocorrelation function depends on the average number of molecules bound within the observed area. TIR/FCS requires no spectroscopic or thermodynamic change between dissociated and complexed states and no extrinsic perturbation from equilibrium. Using TIR/FCS, we determine that rhodamine-labeled immunoglobulin and insulin each nonspecifically adsorb to serum albumin-coated fused silica with both reversible and irreversible components. The characteristic time of the most rapidly reversible component measured is approximately 5 ms and is limited by the rate of bulk diffusion. Rhodamine-labeled bivalent antibodies to dinitrophenyl (DNP) bind to DNP-coated fused silica virtually irreversibly. Univalent Fab fragments of these same antibodies appear to specifically bind to DNP-coated fused silica, accompanied by a large amount of nonspecific binding. TIR/FCS is shown to be a feasible technique for measuring absorption/desorption kinetic rates at equilibrium. In suitable systems where nonspecific binding is low, TIR/FCS should prove useful for measuring specific solute-surface kinetic rates. 相似文献
8.
Schneckenburger H 《Current opinion in biotechnology》2005,16(1):13-18
Recent years have seen the introduction of novel techniques and applications of total internal reflection fluorescence microscopy (TIRFM). Key technical achievements include miniaturization, enhanced depth resolution, reduction of detection volumes and the combination of TIRFM with other microscopic techniques. Novel applications have concentrated on single-molecule detection (e.g. of cellular receptors), imaging of exocytosis or endocytosis, measurements of adhesion foci of microtubules, and studies of the localization, activity and structural arrangement of specific ion channels. In addition to conventional fluorescent dyes, genetically engineered fluorescent proteins are increasingly being used to measure molecular conformations or intermolecular distances by fluorescence resonance energy transfer. 相似文献
9.
Total internal reflection fluorescence microscopy: application to substrate-supported planar membranes 总被引:4,自引:0,他引:4
Nancy L. Thomson Kenneth H. Pearce Helen V. Hsieh 《European biophysics journal : EBJ》1993,22(5):367-378
The use of total internal reflection illumination in fluorescence microscopy (TIRFM) is reviewed with emphasis on application to fluorescent macromolecules that specifically and reversibly bind to planar model membranes supported on glass or quartz substrates. Several methods for characterizing macromolecular motion and organization are discussed: the measurement of equilibrium binding curves to obtain values for equilibrium binding constants; the measurement of fluorescence photobleaching recovery curves to obtain values of kinetic rate constants and surface diffusion coefficients; and the measurement of fluorescence intensities as a function of the evanescent field polarization to characterize orientational order. Applications to cell-substrate contact regions are summarized and future directions of TIRFM are outlined.
Correspondence to: N. L. Thompson 相似文献
10.
Lateral mobility of membrane-binding proteins in living cells measured by total internal reflection fluorescence correlation spectroscopy 下载免费PDF全文
Total internal reflection fluorescence correlation spectroscopy (TIR-FCS) allows us to measure diffusion constants and the number of fluorescent molecules in a small area of an evanescent field generated on the objective of a microscope. The application of TIR-FCS makes possible the characterization of reversible association and dissociation rates between fluorescent ligands and their receptors in supported phospholipid bilayers. Here, for the first time, we extend TIR-FCS to a cellular application for measuring the lateral diffusion of a membrane-binding fluorescent protein, farnesylated EGFP, on the plasma membranes of cultured HeLa and COS7 cells. We detected two kinds of diffusional motion-fast three-dimensional diffusion (D(1)) and much slower two-dimensional diffusion (D(2)), simultaneously. Conventional FCS and single-molecule tracking confirmed that D(1) was free diffusion of farnesylated EGFP close to the plasma membrane in cytosol and D(2) was lateral diffusion in the plasma membrane. These results suggest that TIR-FCS is a powerful technique to monitor movement of membrane-localized molecules and membrane dynamics in living cells. 相似文献
11.
Measuring surface dynamics of biomolecules by total internal reflection fluorescence with photobleaching recovery or correlation spectroscopy. 总被引:17,自引:12,他引:5 下载免费PDF全文
The theoretical basis of a new technique for measuring equilibrium adsorption/desorption kinetics and surface diffusion of fluorescent-labeled solute molecules at solid surfaces has been developed. The technique combines total internal reflection fluorescence (TIR) with either fluorescence photobleaching recovery (FPR) or fluorescence correlation spectroscopy (FCS). A laser beam totally internally reflects at a solid/liquid interface; the shallow evanescent field in the liquid excites the fluorescence of surface adsorbed molecules. In TIR/FPR, adsorbed molecules are bleaching by a flash of the focused laser beam; subsequent fluorescence recovery is monitored as bleached molecules exchange with unbleached ones from the solution or surrounding nonilluminated regions of the surface. In TIR/FCS, spontaneous fluorescence fluctuations due to individual molecules entering and leaving a well-defined portion of the evanescent field are autocorrelated. Under appropriate experimental conditions, the rate constants and surface diffusion coefficient can be readily obtained from the TIR/FPR and TIR/FCS curves. In general, the shape of the theoretical TIR/FPR and TIR/FCS curves depends in a complex manner upon the bulk and surface diffusion coefficients, the size of the iluminated or observed region, and the adsorption/desorption/kinetic rate constants. The theory can be applied both to specific binding between immobilized receptors and soluble ligands, and to nonspecific adsorption processes. A discussion of experimental considerations and the application of this technique to the adsorption of serum proteins on quartz may be found in the accompanying paper (Burghardt and Axelrod. 1981. Biophys. J. 33:455). 相似文献
12.
Fluorescence Correlation Spectroscopy (FCS) can measure diffusion on the cell surface with unparalleled sensitivity. In appropriate situations, this can be the most sensitive and accurate method for measuring receptor interaction and oligomerization. Here we attempt to describe FCS in sufficient detail so that the reader is able to judge when there is a compelling reason to choose this technique, understand the basic theory behind it, construct a FCS spectrometer in the laboratory, and analyze the data to obtain a meaningful estimate of the physical parameters. 相似文献
13.
Precise measurement of diffusion coefficients using scanning fluorescence correlation spectroscopy 总被引:1,自引:0,他引:1
We have implemented scanning fluorescence correlation spectroscopy (sFCS) for precise determination of diffusion coefficients of fluorescent molecules in solution. The measurement volume where the molecules are excited, and from which the fluorescence is detected, was scanned in a circle with radius comparable to its size at frequencies 0.5-2 kHz. The scan radius R, determined with high accuracy by careful calibration, provides the spatial measure required for the determination of the diffusion coefficient D, without the need to know the exact size of the measurement volume. The difficulties in the determination of the measurement volume size have limited the application of standard FCS with fixed measurement volume to relative measurements, where the diffusion coefficient is determined by comparison with a standard. We demonstrate, on examples of several common fluorescent dyes, that sFCS can be used to measure D with high precision without a need for a standard. The correct value of D can be determined in the presence of weak photobleaching, and when the measurement volume size is modified, indicating the robustness of the method. The applicability of the presented implementation of sFCS to biological systems in demonstrated on the measurement of the diffusion coefficient of eGFP in the cytoplasm of HeLa cells. With the help of simulations, we find the optimal value of the scan radius R for the experiment. 相似文献
14.
Background
Fluorescence correlation spectroscopy (FCS) provides information about translational diffusion of fluorescent molecules in tiny detection volumes at the single-molecule level. In normal states, cartilage tissue lacks vascularity, so chondrocyte metabolism depends on diffusion for molecular exchanges. The abundant extracellular matrix (ECM) of cartilage is maintained by a limited number of chondrocytes. ECM plays an important role in the regulation of chondrocyte functions. In this study, FCS was used to measure diffusion behaviors of albumin, the major protein of the intra-articular space, using normal and degenerated cartilage. Preliminary investigation of fluorescence dyes including Alexa 488, Rhodamine 6G and Rhodamine 123 was conducted to evaluate their properties in cartilage. 相似文献15.
16.
Total internal reflection fluorescence microscopy for single-molecule imaging in living cells 总被引:6,自引:0,他引:6
Marvelous background rejection in total internal reflection fluorescence microscopy (TIR-FM) has made it possible to visualize single-fluorophores in living cells. Cell signaling proteins including peptide hormones, membrane receptors, small G proteins, cytoplasmic kinases as well as small signaling compounds have been conjugated with single chemical fluorophore or tagged with green fluorescent proteins and visualized in living cells. In this review, the reasons why single-molecule analysis is essential for studies of intracellular protein systems such as cell signaling system are discussed, the instrumentation of TIR-FM for single-molecule imaging in living cells is explained, and how single molecule visualization has been used in cell biology is illustrated by way of two examples: signaling of epidermal growth factor in mammalian cells and chemotaxis of Dictyostelium amoeba along a cAMP gradient. Single-molecule analysis is an ideal method to quantify the parameters of reaction dynamics and kinetics of unitary processes within intracellular protein systems. Knowledge of these parameters is crucial for the understanding of the molecular mechanisms underlying intracellular events, thus single-molecule imaging in living cells will be one of the major technologies in cellular nanobiology. 相似文献
17.
The cytoskeleton of eukaryotic cells is continuously remodeled by polymerization and depolymerization of actin. Consequently, the relative content of polymerized filamentous actin (F-actin) and monomeric globular actin (G-actin) is subject to temporal and spatial fluctuations. Since fluorescence correlation spectroscopy (FCS) can measure the diffusion of fluorescently labeled actin it seems likely that FCS allows us to determine the dynamics and hence indirectly the structural properties of the cytoskeleton components with high spatial resolution. To this end we investigate the FCS signal of GFP-actin in living Dictyostelium discoideum cells and explore the inherent spatial and temporal signatures of the actin cytoskeleton. Using the free green fluorescent protein (GFP) as a reference, we find that actin diffusion inside cells is dominated by G-actin and slower than diffusion in diluted cell extract. The FCS signal in the dense cortical F-actin network near the cell membrane is probed using the cytoskeleton protein LIM and is found to be slower than cytosolic G-actin diffusion. Furthermore, we show that polymerization of the cytoskeleton induced by Jasplakinolide leads to a substantial decrease of G-actin diffusion. Pronounced fluctuations in the distribution of the FCS correlation curves can be induced by latrunculin, which is known to induce actin waves. Our work suggests that the FCS signal of GFP-actin in combination with scanning or spatial correlation techniques yield valuable information about the local dynamics and concomitant cytoskeletal properties. 相似文献
18.
Diffusion of molecules in the crowded and charged interior of the cell has long been of interest for understanding cellular processes. Here, we introduce a model system of hindered diffusion that includes both crowding and binding. In particular, we obtained the diffusivity of the positively charged protein, ribonuclease A (RNase), in solutions of dextrans of various charges (binding) and concentrations (crowding), as well as combinations of both, in a buffer of physiological ionic strength. Using fluorescence correlation spectroscopy, we observed that the diffusivity of RNase was unaffected by the presence of positively charged or neutral dextrans in the dilute regime but was affected by crowding at higher polymer concentrations. Conversely, protein diffusivity was significantly reduced by negatively charged dextrans, even at 0.4 μM (0.02% w/v) dextran. The diffusivity of RNase decreased with increasing concentrations of negative dextran, and the amount of bound RNase increased until it reached a plateau of ∼80% bound RNase. High salt concentrations were used to establish the electrostatic nature of the binding. Binding of RNase to the negatively charged dextrans was further confirmed by ultrafiltration. 相似文献
19.
Radek Macháň 《生物化学与生物物理学报:生物膜》2010,1798(7):1377-2739
Investigation of lipid lateral mobility in biological membranes and their artificial models provides information on membrane dynamics and structure; methods based on optical microscopy are very convenient for such investigations. We focus on fluorescence correlation spectroscopy (FCS), explain its principles and review its state of the art versions such as 2-focus, Z-scan or scanning FCS, which overcome most artefacts of standard FCS (especially those resulting from the need for an external calibration) making it a reliable and versatile method. FCS is also compared to single particle tracking and fluorescence photobleaching recovery and the applicability and the limitations of the methods are briefly reviewed. We discuss several key questions of lateral mobility investigation in planar lipid membranes, namely the influence which membrane and aqueous phase composition (ionic strength and sugar content), choice of a fluorescent tracer molecule, frictional coupling between the two membrane leaflets and between membrane and solid support (in the case of supported membranes) or presence of membrane inhomogeneities has on the lateral mobility of lipids. The recent FCS studies addressing those questions are reviewed and possible explanations of eventual discrepancies are mentioned. 相似文献
20.
Probing diffusion laws within cellular membranes by Z-scan fluorescence correlation spectroscopy 下载免费PDF全文
Humpolícková J Gielen E Benda A Fagulova V Vercammen J Vandeven M Hof M Ameloot M Engelborghs Y 《Biophysical journal》2006,91(3):L23-L25
The plasma membrane of various mammalian cell types is heterogeneous in structure and may contain microdomains, which can impose constraints on the lateral diffusion of its constituents. Fluorescence correlation spectroscopy (FCS) can be used to investigate the dynamic properties of the plasma membrane of living cells. Very recently, Wawrezinieck et al. (Wawrezinieck, L., H. Rigneault, D. Marguet, and P. F. Lenne. 2005. Biophys. J. 89:4029-4042) described a method to probe the nature of the lateral microheterogeneities of the membrane by varying the beam size in the FCS instrument. The dependence of the width of the autocorrelation function at half-maximum, i.e., the diffusion time, on the transverse area of the confocal volume gives information on the nature of the imposed confinement. We describe an alternative approach that yields essentially the same information, and can readily be applied on commercial FCS instruments by measuring the diffusion time and the particle number at various relative positions of the cell membrane with respect to the waist of the laser beam, i.e., by performing a Z-scan. 相似文献