首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Valproyl taurinamides are a novel group of compounds that possess anticonvulsant activity. In this study a gas chromatographic micromethod was developed for the quantification of selected valproyl taurinamides and some of their metabolites in biological samples. Valproyl taurinamide (VTD), N-methyl valproyl taurinamide (M-VTD), N,N-dimethyl valproyl taurinamide (DM-VTD) and N-isopropyl valproyl taurinamide (I-VTD) were analyzed in mouse and dog plasma and in dog urine using gas chromatography. Flame ionization detection and mass spectrometric detection were compared. The plasma samples were prepared by solid-phase extraction using C(18) cartridges. The urine samples were prepared by liquid-liquid extraction. The sample volume used was 100 microl of dog plasma, 50 microl of mouse plasma and 20 microl of dog or mouse urine. The quantification range of the method was 1.5-50 mg/l in dog plasma (VTD only), 2.5-250 mg/l in mouse plasma (0.7-90 pmol injected) and 0.04-2 mg/ml in dog urine (VTD only). The inter-day precision in plasma and urine samples was around 10% for all quantified concentrations except LOQ (15-20%). The accuracy for all four compounds was between 90 and 110% within the entire concentration range. The developed method was suitable for quantification of a series of CNS-active valproyl taurineamide derivatives in biological samples at relevant in vivo concentrations.  相似文献   

2.
A method utilizing capillary GC and flame ionization detection was developed for the simultaneous determination of 1-methoxy-2-propanol (propylene glycol monomethyl ether; PGME) and its metabolite 1,2-propanediol (propylene glycol; PG) in rat and mouse plasma. The calibration graphs for rat and mouse plasma were linear with correlation coefficients at>0.997 over the range 2–700 μg/ml. The limit of quantification was ca. 2 μg/ml (2 ng on-column) for both compounds in plasma of each species. The ranges of the precision and accuracy for PGME were 2.8–8.8% and 3.2–13%, respectively, and for PG were 11–26% and 10–25%, respectively. The recovery of PGME from rat and mouse plasma was ca. 73% and for PG it was ca. 65 and 31% from rat and mouse plasma, respectively. The method was used to study the oral absorption and metabolism of PGME in mice. PGME was readily absorbed and metabolized to PG following oral gavage administration at 90 mg/kg. The maximum concentrations of PGME and PG in plasma were attained at 20 and 30 min following dosing, respectively.  相似文献   

3.
Manumycin A is a natural antibiotic produced by Streptomyces parvulus that has antineoplastic activity against a variety of human cancers in nude mouse models. We have developed a highly sensitive reverse phase high-performance liquid chromatography (HPLC) method based on ultraviolet (UV) detection for the determination of manumycin A in mouse plasma. Manumycin A was isolated from mouse plasma by solid-phase extraction. A gradient elution of methanol and 0.05 M H(3)PO(4) with 0.2% triethylamine mobile phase was employed and separation was achieved with a C(18) analytical column. Manumycin A was detected by UV absorption at 345 nm. Retention time for manumycin A was 8.9+/-0.2 min. The manumycin A peak was baseline resolved, with the nearest peak at 1.5 min distance and no interfering peaks detected. Inter- and intra-day coefficients of variance were less than 6.1 and 5.1%, respectively. Based on an extracted manumycin A standard plasma sample of 0.25 microg/ml, the assay precision was 99.8% with a mean accuracy of 95.1%. At plasma concentrations of 0.5 and 5 microg/ml, the mean recovery rates of manumycin A were 59.64 and 60.28%, respectively. The lower limit of detection (LLD) for manumycin A was 0.1 microg/ml in mouse plasma. The lower limit of quantification (LLQ) for manumycin A was 0.125 microg/ml. Results of the stability study indicated that when frozen at -80 degrees C, manumycin A was stable in mouse plasma for up to 2 weeks. This method is useful in quantification of manumycin A in mouse plasma for clinical pharmacology studies in mice.  相似文献   

4.
A method for the quantitation of DB-67 ((20S)-10-hydroxy-7-tert-butyldimethylsilylcamptothecin) lactone and carboxylate in mouse plasma has been developed, validated, and applied in pharmacokinetic studies. The analytes were separated by reversed-phase chromatography with fluorescence detection. Validation demonstrated the selectivity and specificity for the carboxylate and lactone, with linearity between 1-300ng/mL and 2.5-300ng/mL for the carboxylate and lactone, respectively (accuracy 90-110% of theory and coefficient of variation < or =5.7%). Carboxylate to lactone conversion was <4% using this method. The assay was found to be suitable for the analysis of DB-67 lactone and carboxylate in pharmacokinetic studies following intravenous administration of DB-67 or its delta-aminobutyric acid ester derivative.  相似文献   

5.
Gadocoletate ion is a new paramagnetic intravascular contrast agent for magnetic resonance imaging (MRI). An high-performance liquid chromatographic method for assaying Gadocoletate ion in human plasma, urine and faecal samples is described. The analysis is based on the reversed-phase chromatographic separation of Gadocoletate ion from the endogenous components of the biological matrices and its detection during elution by ultraviolet light absorption at 200 nm. The selectivity of the method was satisfactory. The mean absolute recovery during the analytical sample preparation was greater than 87%. The precision, expressed as coefficient of variation (CV%) ranged from 0.29 to 5.90% and the accuracy, expressed as mean relative error (R.E.%) of the analytical method ranged from -3.7 to +7.1%. The detection limit in plasma and urine was 2.01 and 10.0 microg/mL (0.00203 and 0.0101 micromol/mL), respectively. The detection limit in homogenized faecal samples was 17.7 microg/g (0.0179 micromol/g). Stability studies were performed in human plasma and urine samples during the analytical cycle. Gadocoletate ion was shown to be stable in human plasma and in human urine when stored at about +4 degrees C for up 24 h, and after three freeze-thaw cycles. In addition, it was shown to be stable in samples of processed plasma and in diluted urine at about +4 degrees C for 48 h, and at room temperature for at least 24 h. As regards the long-term stability of Gadocoletate ion, the results of dedicated studies showed that Gadocoletate ion is stable in human plasma samples when stored at +4 degrees C for up to 30 days and at -80 degrees C for up to 90 days. Gadocoletate ion is stable in samples of human urine when stored at +4 degrees C for up to 30 days, and when stored at -20 degrees C and at -80 degrees C for up to 90 days. The method has been successfully validated in human plasma, urine and faeces and it has been shown to be precise, accurate and reliable.  相似文献   

6.
This paper describes a simple, rapid and reproducible high-performance liquid chromatographic method (HPLC) with ultraviolet absorbance detection for the analysis of melphalan in plasma. The HPLC column was an Ultrasphere ODS (5 μm) and the eluent was composed of methanol, purified water and acetic acid (49.5:49.5:1, v/v). The detection was performed at 261 nm. The method involved a simple treatment of the samples with methanol. The propylparaben was used as internnal standard. Linear detection response was obtained for concentrations ranging from 50 to 2500 ng/ml. Recovery from plasma proved to be more than 90%. Precision, expressed as C.V., was in the 0.5 to 9% range. Accuracy ranged from 95 to 102%. This method was used to determine the pharmacokinetic parameters of melphalan following high-dose (140 mg/m2) intravenous administration in patients with advanced malignancies undergoing peripheral blood hematopoietic progenitor-cell transplantation.  相似文献   

7.
A method for the analysis of the AMPA (α-amino-3-hydroxy-5-methyl-4-isoxazolepropionate) receptor antagonist LY300164 (compound I) and its N-acetyl metabolite (compound II) in plasma was developed. The assay utilized solid-phase extraction on a C18 Bond Elut cartridge followed by reversed-phase HPLC with UV detection at 310 nm. The method exhibited a large linear range from 0.05 μg/ml to 50 μg/ml with an intra-sassay accuracy for compound I and compound II ranging from 89.0% to 114.5% and intra-assay precision ranging from 0.5 to 15.3% in mouse, rat, dog, and monkey plasma. The inter-assay accuracy of compound I and compound II was 93.3% to 101.8% and the inter-assay precision was 1.6% to 11.2% in dog plasma. The lower limit of quantitation was 0.05 μg/ml for compound I in plasma from all species tested. The lower limit of quantitation for compound II was 0.05 μg/ml in dog and monkey plasma and 0.1 μg/ml in mouse and rat plasma. Extracts of compound I and II from dog plasma were shown to be stable for 24 h at room temperature, and both compounds were stable when spiked into rat and monkey plasma frozen at −70°C for 27 days. The method has shown to be useful in the investigation of the pharmacokinetics of the parent compound (I) and metabolite (II) in preclinical studies.  相似文献   

8.
A simple and sensitive high-performance liquid chromatographic (HPLC) method utilizing fluorescence detection was developed for the determination of the phosphodiesterase type 5 inhibitor tadalafil in mouse plasma. This method utilizes a simple sample preparation (protein precipitation) with high recovery of tadalafil (∼98%), which eliminates the need for an internal standard. For constituent separation, the method utilized a monolithic C18 column and a flow rate of 1.0 mL/min with a mobile phase gradient consisting of aqueous trifluoroacetic acid (0.1% TFA in deionized water pH 2.2, v/v) and acetonitrile. The method calibration was linear for tadalafil in mouse plasma from 100 to 2000 ng/mL (r > 0.999) with a detection limit of approximately 40 ng/mL. Component fluorescence detection was achieved using an excitation wavelength of 275 nm with monitoring of the emission wavelength at 335 nm. The intra-day and inter-day precision (relative standard deviation, RSD) values for tadalafil in mouse plasma were less than 14%, and the accuracy (percent error) was within −14% of the nominal concentration. The method was utilized on mouse plasma samples from research evaluating the potential cardioprotective effects of tadalafil on mouse heart tissue exposed to doxorubicin, a chemotherapeutic drug with reported cardiotoxic effects.  相似文献   

9.
A chromatographic method for the determination of pyridinoline (Pyr) and deoxypyridinoline (Dpyr) in serum and plasma is described. The analytical procedure involved plasma or serum purification by ultrafiltration (20 000 relative molecular mass cut-off) under centrifugation at 2500 g for 4 h, as an innovative step. Analysis was done by isocratic high-performance liquid chromatography with fluorescence detection. The linearity of the method was tested from 0.6 to 15 pmol/ml and 0.12 to 3 pmol/ml for Pyr and Dpyr, respectively. The detection limit was 60 fmol/ml for both crosslinks. Except for Dpyr in plasma (coefficient of variation 19.9%), intra-assay variation was always below 10% in serum and plasma. The method has been applied to the quantification of crosslinks in serum and plasma of healthy volunteers and also in mouse and rat plasma. Serum proved to be the most suitable biological fluid for the systemic measurement of these compounds in humans and under the experimental conditions used, contained an average of 3.62 ± 0.65 and 0.7 ± 0.18 pmol/ml Pyr and Dpyr, respectively.  相似文献   

10.
We present a method for determining two cephalosporins (cefoperazone and ceftiofur) in plasma by on-line solid-phase extraction (SPE)-capillary zone electrophoresis (CZE) with a T-split interface. Using this interface, a part of the SPE elution plug containing the cephalosporins is injected while the rest of the sample is flushed to waste. SPE was carried out using a C(18) micro-precolumn and the cephalosporins presented good retention properties with breakthrough volumes above 1 ml. Using a desorption volume of 426 nl of acetonitrile, recoveries were 75 and 90%, for cefoperazone and ceftiofur, respectively. The resulting elution volume was about 1.8 microl. A deproteinization step was included prior to SPE for the analysis of plasma samples with recoveries of 90 and 57% for cefoperazone and ceftiofur, respectively. With UV detection at 254 nm, linear relationships between the injected concentration and peak area was measured between 10 and 500 ng ml(-1) for standards, and 200 and 1500 ng ml(-1) for plasma samples. Intra-day (n=5) and inter-day (n=5) peak area repeatability were lower than 12% RSD. The detection limits obtained for spiked plasma (100 ng ml(-1) cefoperazone and ceftiofur) are sufficient for applying the method to pharmacokinetic studies.  相似文献   

11.
A sensitive and specific analytical method for a potent antitumor agent, TZT-1027, in plasma has been developed using liquid chromatography–mass spectrometry (LC–MS) with [2H4]TZT-1027 as an internal standard (I.S.). A plasma sample was purified by solid-phase extraction on a C18 cartridge, followed by solvent extraction with diethyl ether. The extract was then injected into the LC–MS system. Chromatography was carried out on a C18 reversed-phase column using acetonitrile–0.05% trifluoroacetic acid (TFA) (55:45) as a mobile phase. Mass spectrometric analysis was performed in atmospheric pressure chemical ionization (APCI) mode with positive ion detection, and the protonated molecular ions ([M+H]+) of TZT-1027 and I.S. were monitored to allow quantitation. The method was applied to the determination of TZT-1027 in human, monkey, dog, rat and mouse plasma. As far as the sample preparation was concerned, good recoveries (73.5–99.1%) were obtained. The calibration curves were linear over the range of 0.25–100 ng per 1 ml of human, dog and rat plasma, per 0.5 ml of monkey plasma, and per 0.1 ml of mouse plasma. From the intra- and inter-day accuracy and precision, the present method satisfies the accepted criteria for bioanalytical method validation. TZT-1027 was stable when stored below −15°C for 6 months in human plasma and for 3 weeks in plasma from other species. TZT-1027 was also stable in plasma through at least three freeze–thaw cycles.  相似文献   

12.
A simple, rapid and low cost sample preparation method was developed for quantification of docetaxel in mouse plasma by high-performance liquid chromatography/tandem mass spectrometry with paclitaxel as the internal standard. A small volume of plasma (40 microl) and one-step protein precipitation using methanol and acetonitrile (1:1 (v/v)) were used for sample preparation. The calibration curve for docetaxel in mouse plasma was linear over the range 25-2500 nM. The detection limit was 8 nM. The lower limit of quantitation is 25 nM. The intra- and inter-day precisions (CV) of analysis were 9.5 and 9.7% for the low quality control (LQC), 5.5 and 4.9% for the medium quality control (MQC) and 3.9 and 6.3% for the high quality control (HQC), respectively. The accuracy was 102.5% for LQC, 97.9% for MQC and 108.8% for HQC. This assay has now been applied to evaluation of mouse pharmacogenetics and other clinical pharmacology applications.  相似文献   

13.
A rapid and selective high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method for simultaneous determination of isoniazid (INH), rifampicin (RFP) and levofloxacin (LVX) in mouse tissues and plasma has been developed and validated, using gatifloxacin as the internal standard (I.S.). The compounds and I.S. were extracted from tissue homogenate and plasma by a protein precipitation procedure with methanol. The HPLC separation of the analytes was performed on a Welch materials C4 column (250 mm × 4.6 mm, 5.0 μm, USA) at 25 °C, using a gradient elution program with the initial mobile phase constituting of 0.05% formic acid and methanol (93:7, v/v) at a flow-rate of 1.0 ml/min. For all the three analytes, the recoveries varied between 83.3% and 98.8% in tissues and between 75.5% and 90.8% in plasma, the accuracies ranged from 91.7% to 112.0% in tissues and from 94.6% to 108.8% in plasma, and the intra- and inter-day precisions were less than 13.3% in tissues and less than 8.2% in plsama. Calibration ranges for INH were 0.11–5.42 μg/g in tissues and 0.18–9.04 μg/ml in plasma, for RFP were 0.12–1200 μg/g in tissues and 4.0–200 μg/ml in plasma, and for LVX were 0.13–26.2 μg/g in tissues and 0.09–4.53 μg/ml in plasma. The lower limits of quantification (LLOQs) for INH, RFP and LVX in mouse tissues were 0.11, 0.12 and 0.13 μg/g and for those in mouse plasma were 18.1, 20.0 and 21.8 ng/ml, respectively. The limits of detection (LODs) for INH, RFP and LVX in mouse tissues were 0.04, 0.05 and 0.05 μg/g and for those in mouse plasma were 5.5, 6.0 and 6.6 ng/ml, respectively. The established method was successfully applied to simultaneous determination of isoniazid, rifampicin and levofloxacin in mouse plasma and different mouse tissues.  相似文献   

14.
WIN 33377 (I) is a member of a novel class cytotoxic antitumor agents, 4-aminomethyl thioxanthane derivatives. A simple, rapid and reproducible method has been developed for the assay of I in mouse plasma using a high-performance liquid chromatographic method utilizing a column-switching technique. The method involves direct injection of buffered plasma to the extraction column for sample clean-up followed by switching onto an analytical column for analysis with UV detection at 256 nm. The method has demonstrated accuracy and precision over the range 10–2500 ng/ml using a 100-μl plasma sample with a minimum quantifiable level at 10 ng/ml. Stability of mouse plasma samples was demonstrated after storage for 4 weeks at −15 to −20°C, as was the ability of samples to be accurately quantified after a maximum of three freeze-thaw cycles. Recovery was greater than 87% for the compound and the internal standard. The assay was accurate and reproducible with measured values lying within the limits of defined acceptance criteria. The utility of the method was demonstrated by analyzing plasma samples obtained from mice dosed with I as part of a pre-clinical safety study intended to assist in the design of a pharmacokinetically guided dose escalation strategy.  相似文献   

15.
A rapid and sensitive high-performance liquid chromatographic (HPLC) assay has been developed to allow determination of total (i.e. bound and unbound) and free (i.e. unbound) topotecan (TPT) in mouse plasma in the presence and absence of anti-TPT antibodies. The chromatographic analysis was carried out using reversed-phase isocratic elution with a Nova-Pak C18 column (3.9 mm x 150 mm, 4 microm) protected by a Nova-Pak C18 guard column (3.9 mm x 20 mm, 4 microm), where 10 mM KH(2)PO(4)-methanol-triethylamine (72:26:2 (v/v/v), pH 3.5) was used as the mobile phase. Topotecan was quantified with fluorescence detection using an excitation wavelength of 361 nm and an emission wavelength of 527 nm. The retention time for the internal standard, acridine, and TPT were 7.4 and 9.0 min, respectively. The lower limit of quantitation (LOQ) for TPT was determined as 0.02 ng in mouse plasma and mouse plasma ultrafiltrate, corresponding to a concentration of 1 ng/ml in 20 microl mouse plasma. The assay was shown to be linear over a concentration range of 1-500 ng/ml. The recoveries of free and total TPT from spiked mouse plasma were within 10% of theoretical values (assessed at 1, 20 and 500 ng/ml). The validated HPLC assay was applied to evaluate TPT pharmacokinetics following administration of TPT to Swiss Webster mice and to hyperimmunized and control BALB/c mice. The assay has been shown to be capable for measuring total and free TPT in mouse plasma with high sensitivity and will allow the testing of the effect of anti-TPT antibodies on the disposition of TPT.  相似文献   

16.
A sensitive and simple HPLC method was developed for the determination of a novel compound, a potential anti-cancer drug, N-(2-hydroxy-5-nitrophenylcarbamothioyl)-3,5-dimethylbenzamide (DM-PIT-1), a member of the new structural class of non-phosphoinositide small molecule antagonist of phosphatidylinositol-3,4,5-trisphosphate-pleckstrin-homology domain interactions, in mouse plasma and tumor tissue homogenates. The chromatographic separation of DM-PIT-1 was achieved on C18 column using isocratic elution with acetonitrile-water (70:30) containing 0.1% formic acid (v/v). DM-PIT-1 was detected by UV absorbance at 320 nm and confirmed by LC-MS. The extraction of the DM-PIT-1 from the plasma and tumor tissue with methylene chloride resulted in its high recovery (70-80%). HPLC calibration curves for DM-PIT-1 based on the extracts from the mouse plasma and tumor tissue samples were linear over a broad concentration range of 0.25-20 μg/ml/g, with intra/inter-day accuracy of 95% and the precision of variation below 10%. The limits of detection and quantification were 0.1 ng and 0.2 ng, respectively. The described method was successfully applied to study the pharmacokinetics of the DM-PIT-1 following the parenteral injections of DM-PIT-1 entrapped in 1,2-disteratoyl-sn-glycero-3-phosphoethanolamine-N-[methoxy(polyethylene-glycol)-2000] (PEG-PE) micelles.  相似文献   

17.
A liquid chromatographic method with ultraviolet detection was developed for the analysis of the recent antidepressant sertraline and its main metabolite N-desmethylsertraline in human plasma. The analytes were separated on a C8 reversed phase column, using a mobile phase composed of acetonitrile and a 12.3 mM, pH 3.0 phosphate buffer containing 0.1% triethylamine (35:65, v/v). Clomipramine was used as the Internal Standard. Using a solid phase extraction procedure with C2 cartridges high extraction yields (>94%) and good purification from matrix interference were obtained. Good linearity was obtained in the 7.5-250.0 ng mL(-1) range for sertraline and in the 10-500 ng mL(-1) range for N-desmethylsertraline. The analytical method was validated in terms of precision, extraction yield and accuracy. These assays gave R.S.D.% values for precision always lower than 3.9% and mean accuracy higher than 90%. Thanks to its good selectivity, the method proved to be suitable for the analysis of plasma samples from patients treated with sertraline as either monotherapy or polypharmacy.  相似文献   

18.
A rapid method for the determination of 4-methylpyrazole (4-MP) levels in plasma and in dialysate by isocratic reversed-phase high-performance liquid chromatography with UV detection is described. The internal standard was the 3-methylpyrazole (3-MP). Plasma sample preparation consisted of a protein precipitation. Dialysate samples were injected without preparation. The method was linear up to 30 mg l−1 in plasma and up to 5 mg l−1 in dialysate. The within-day precisions (C.V.) were less than 4% in plasma and were less than 2% in dialysate. The day-to-day precisions (C.V.) were less than 7% in plasma and were less than 3% in dialysate. This method is easy to perform and has practical interest for clinicians who need to monitor in emergency 4-MP levels in ethylene glycol and methanol poisonings.  相似文献   

19.
To support toxicokinetic assessments, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of BMS-790052 in rat, dog, monkey, rabbit and mouse K(2)EDTA plasma. The drug was isolated from buffered samples using ISOLUTE C8 96-well solid phase extraction (SPE) plates. Chromatographic separation was achieved on a Waters Atlantis dC18 analytical column (2.1 mm × 50 mm, 5 μm) with detection accomplished using an API 4000 tandem mass spectrometer in positive ion electrospray and multiple reaction monitoring (MRM) mode. The standard curves, which ranged from 5.00 to 2000 ng/mL for BMS-790052, were fitted to a 1/x(2) weighted linear regression model. The intra-assay precision (%CV) and inter-assay precision (%CV) were within 8.5%, and the assay accuracy (%Dev) was within ±7.1 for rat, dog, monkey, rabbit and mouse K(2)EDTA plasma. This accurate, precise, and selective SPE/LC-MS/MS method has been successfully applied to analyze several thousands of non-clinical study samples.  相似文献   

20.
A simplified method for the simultaneous determination of irinotecan (CPT-11, I) and its active metabolite (SN-38, II) in human plasma by high-performance liquid chromatography (HPLC) with fluorescence detection has been developed. Following the addition of the internal standard (I.S.) camptothecin, the drugs were extracted from plasma using methanol. The average extraction efficiencies were 87% for I, 90% for II and 90% for the I.S. Chromatography was performed using a TSK gel ODS-80Ts column, monitored at 556 nm (excitation wavelength, 380 nm) and the mobile phase was acetonitrile-50 mM disodium hydrogen phosphate (28:72) containing 5 mM heptanesulphonate (pH 3.0). The linear quantitation ranges for I and II were 30–2000 and 1–30 ng/ml, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号