1.
Early problems after implantation of an endocardial electrode for permanent pacing occur in many patients. Difficulties can be anticipated in many of these patients and their management made much easier by a knowledge of the daily endocardial threshold obtained in patients with an implanted Elema Verio pacing unit by a simple non-invasive technique using a magnet and electrocardiogram. Twenty patients are described in whom permanent pacing with an Elema Vario unit was undertaken. The practical advantages of this unit can be readily seen in the patient who developes exit block or in the patient with obstructive airways disease, in whom frequent coughing or right ventricular hypertrophy may make stable electrode placement difficult. The chief advantage of the Elema Vario pacemaker is the extreme simplicity with which knowledge of the endocardial threshold can be obtained.  相似文献   

2.
The virtual electrode polarization (VEP) effect is believed to play a key role in electrical stimulation of heart muscle. However, under certain conditions, including clinically, its existence and importance remain unknown. We investigated the influence of acute tissue damage produced by continuous pacing with strong current (40-mA, 4-ms biphasic pulses with 4-Hz frequency for 5 min) on stimulus-generated VEPs and pacing thresholds. A fluorescent optical mapping technique was used to obtain stimulus-induced transmembrane potential distribution around a pacing electrode applied to the ventricular surface of a Langendorff-perfused rabbit heart (n = 5). Maps and pacing thresholds were recorded before and after tissue damage. Spatial extents of electroporation and cell uncoupling were assessed by propidium iodide (n = 2) and connexin43 (n = 3) antibody staining, respectively. On the basis of these data, passive and active three-dimensional bidomain models were built to determine VEP patterns and thresholds for different-sized areas of the damaged region. Electrophysiological results showed that acute tissue damage led to disappearance of the VEP with an associated significant increase in pacing thresholds. Damage was expressed in electroporation and cell uncoupling within an approximately 1.0-mm-diameter area around the tip of the electrode. According to computer simulations, cell uncoupling, rather than electroporation, might be the direct cause of VEP elimination and threshold increase, which was nonlinearly dependent on the size of the damaged region. Fiber rotation with depth did not substantially affect the numerical results. The study explains failure to stimulate damaged tissue within the concepts of the VEP theory.  相似文献   

3.
The electrophysiological properties of atrioventricular (AV) nodal dual pathways have traditionally been investigated with premature stimuli delivered with right atrial pacing. However, little is known about the functional characteristics of AV nodal inputs outside of this context. Superfused rabbit triangle of Koch preparations (n = 8) and Langendorff-perfused hearts (n = 10) were paced throughout the triangle of Koch and mapped electrically and optically for activation pattern, electrogram and optical action potential morphologies, stimulation thresholds, and stimulus-His (S-H) intervals. Optical mapping and changes in His electrogram morphology were used to confirm the activation pathway. Pacing stimuli >or=2 mm above the tricuspid valve caused fast-pathway activation of the AV node and His with a threshold of 2.4 +/- 1.6 mA. An area directly below the coronary sinus had high thresholds (8.6 +/- 1.4 mA) that also resulted in fast-pathway excitation (P < 0.001). S-H intervals (81 +/- 19 ms) for fast-pathway activation remained constant throughout the triangle of Koch, reflecting the AV delay. Stimuli applied <2 mm from the tricuspid valve resulted in slow pathway (SP) excitation or direct His excitation (4.4 +/- 2.2 mA threshold; P < 0.001 compared with fast pathway). For SP/His pacing, S-H intervals showed a strong dependence on the distance from the His electrode and were significantly lower than S-H intervals for fast-pathway activation. SP/His pacing also displayed characteristic changes in His electrogram morphology. In conclusion, optical maps and S-H intervals for SP/His activation suggest that AV conduction via SP bypasses the compact AV node via the lower nodal bundle, which may be utilized to achieve long-term ventricular synchronization.  相似文献   

4.
Of the 353 patients followed in the pacemaker surveillance clinic between July 1976 and July 1977, 25 patients complained of episodes of dizziness and faintness. 20 of these had normal pacing function and pacemaker parameters at routine clinic testing. 18 patients had 'demand' units and 2 had fixed-rate pacemakers. The indication for permanent pacing was complete heart block in 16 patients and sinoatrial disease in 5 patients. At clinic follow-up, there was unequivocal evidence of vertebrobasilar insufficiency in 5 patients and postural hypotension in 4 patients. In 11 patients, the cause of presyncope was not evident at the clinic. All patients were monitored by 24-hour tape recording until an episode of pre-syncope occurred. In 8 patients, there was evidence of intermittent failure to pace associated with the episodes of presyncope. In 2 patients, an additional cause for presyncope was found at clinic examination. Ambulatory 24-hour tape monitoring of the electrocardiogram is an important adjunct to pacemaker follow-up especially when other methods such as transtelephone monitoring are not available in the United Kingdom. Routine electronic testing of pacemaker function does not always reveal intermittent abnormalities related to changes in threshold or unstable electrode positions.  相似文献   

5.
A patient with complete atrioventricular block was fitted with a temporary endocardial pacing wire via a right subclavian percutaneous approach. The result was initially satisfactory, but within a few days radiography for left-sided chest pain showed pneumopericardium. A permanent epicardial pacing system was therefore substituted and she remained well for three months. She was then admitted for syncope: the pacemaker was failing to capture, and radiography showed pericardial and pleural effusion. A new permanent endocardial pacing system using a wedged electrode was inserted and she made an uncomplicated recovery. Pneumopericardium complicating endocardial pacing has apparently not been reported before. Presumably the electrode had penetrated both the right ventricle and the pericardium into the adjacent lung.  相似文献   

6.
Transvenous endocardial pacing through classical implantation of a pace/sensing lead in the right ventricle is strictly contraindicated in patients with a mechanical tricuspid valve. Usually permanent pacing is achieved by an epimyocardial surgical approach. We hereby describe the implantation of a single site left ventricle pacing lead in the anterior interventricular vein in a 60 year-old woman with symptomatic bradycardia, permanent atrial fibrillation, and mechanical tricuspid valve. The described use of left ventricle pacing through a coronary vein lead, in a patient with favorable venous anatomy, provided (through a minimal invasive approach) effective with a low and stable threshold.  相似文献   

7.
N D Berman 《CMAJ》1980,123(3):190-193
A temporary pacing electrode can function as a diagnostic as well as a therapeutic tool. This is illustrated in two patients whose permanent pacemakers unexpectedly failed. In the first patient a demand pacemaker was inhibited by a magnet rather than converting to the asynchronous mode. In the second the pacemaker appeared to be producing low-voltage potentials not detectable on the surface electrocardiogram. The presence of a temporary pacing electrode can be useful for defining the cause of pacemaker failure and the nature of any associated arrhythmias.  相似文献   

8.
A commercially available magnetic therapy system, designed for clinical application as well as for private use without medical supervision, was examined with respect to its potential for causing electromagnetic interference with implantable pacemakers (PMs) and automatic implantable cardioverter defibrillators (AICDs). A sample of 15 PMs and 5 AICDs were experimentally investigated. Each of the implants was realistically positioned in a homogeneous, electrically passive torso phantom and exposed to the magnetic fields of the system's applicators (whole body mat, cushion, and bar applicator). The detection thresholds of the implants were programmed to maximum sensitivity and both unipolar as well as bipolar electrode configurations were considered. The evaluation of possible interferences was derived from the internal event storages and pacing statistics recorded by the implants during exposure. Any "heart activity" recorded by the implants during exposure was interpreted as a potential interference, because the implant obviously misinterpreted the external interference signal as a physiological signal. Only cases without any recorded "heart activity" and with nominal pacing rates (as expected from the program parameter settings) of the implants were rated as "interference-free." Exposure to the whole body mat (peak magnetic induction up to 265 microT) did not show an influence on PMs and AICD in any case. The cushion applicator at the highest field intensity (peak magnetic induction up to 360 microT) led to atrial sensing defects in four PM models with unipolar electrode configuration. Under bipolar electrode configuration no disturbances occurred. The bar applicator led to sensing problems and consecutively reduced pacing rates in all tested PM models under unipolar electrode configuration and maximum field intensity (peak magnetic induction up to 980 microT). Bipolar electrode configuration resolved the problem. The investigated AICDs did not show malfunctions under any investigated condition. In conclusion, the examined PEMF therapy system did not interfere with the investigated implantable cardiac devices with bipolar electrode configuration. However, unipolar electrode configuration in pacemakers seems to be potentially hazardous during application of the examined PEMF therapy system.  相似文献   

9.
Dwight I. Peretz 《CMAJ》1967,96(8):451-456
The mortality rate is high from advanced atrioventricular block associated with acute myocardial infarction. There is reason to believe that if in these patients the hearts are electrically paced with an endocardial pacing catheter, the mortality rate can be considerably decreased. Five patients in second- and third-degree heart block associated with acute myocardial infarction were paced with a considerable lowering of the expected mortality rate. Twenty-three cases from the literature are also presented and discussed. A silastic bipolar electrode catheter was used in these five cases. Four of the five cases returned to normal sinus rhythm within the first 10 days. The average duration of pacing was 6.7 days. It is the opinion of the author that second- and third-degree heart block associated with acute myocardial infarction should have a pacing catheter introduced at the earliest possible moment for continuous or demand endocardial pacing.  相似文献   

10.
Nonuniform conduction may cause block and/or delay, thereby providing a substrate for the onset and maintenance of reentrant atrial arrhythmias. We tested the hypothesis that linear triple-site, bipolar, rapid pacing (LTSBRP) of the right atrium generates more uniform wave-front propagation compared with single-site, bipolar, rapid pacing (SSBRP), thereby reducing and/or eliminating conduction block and delay that is otherwise present. Five dogs with pericarditis and three normal dogs were studied. Three plunge-wire electrode pairs were placed 5-7 mm apart in both perpendicular and parallel configurations at the superior aspect of the crista terminalis and were used to pace at 200- and 300-ms cycle lengths for < or =6 s. During pacing, 380 electrograms were recorded simultaneously from electrode arrays placed epicardially on the atria, which produced activation sequence maps for each pacing episode. Local conduction-velocity vectors were computed for each site during each episode. Histograms of absolute velocity vector angles from the x-axis (of the crista terminalis) were plotted to assess uniformity of wave-front propagation, and the magnitude of each vector was computed to assess the local speed. LTSBRP showed 1) more uniform linear activation wave fronts compared with SSBRP, 2) velocity vectors with a more uniform magnitude and direction compared with SSBRP, 3) a predominant absolute velocity vector angle vs. a scattered angle distribution with SSBRP, and 4) shorter right atrial activation time and faster mean epicardial speed than SSBRP for each pacing cycle length. LTSBRP created a more uniform wave-front propagation with less or no conduction block and/or delay compared with SSBRP.  相似文献   

11.
OBJECTIVE--To compare present pacing practice with the recommendations recently published by the British Pacing and Electrophysiology Group and to assess the increase in annual budget required to implement these recommendations in a regional cardiothoracic unit. DESIGN--Retrospective analysis of pacemaker implantation for 1991 with calculation of the costs required to implement the group''s recommendations based on average 1991 costs of the types of pacing generators and electrode leads used. SETTING--Regional cardiothoracic unit for South West Thames Health Authority. PATIENTS--433 consecutive patients receiving permanent pacemaker generators: 76 (18%) with sinus node disease; 270 (62%) with atrioventricular block; 25 (6%) with both sinus node disease and atrioventricular block; 59 (14%) with chronic atrial fibrillation and atrioventricular block; and 3 (1%) with carotid sinus or malignant vasovagal syndromes. RESULTS--Only 102 (24%) patients received pacemaker generators recommended by the British Pacing and Electrophysiology Group; however, 355 (82%) patients were older than 65 years, and 264 (61%) were aged 75 or over. The cost of hardware for pacing was 462,885 pounds. Using generators as recommended would have cost 810,525 pounds for "optimal" systems (an increase of 75%) and 710,750 pounds for "alternative" systems (an increase of 54%). These increases would have been considerably reduced by limiting the use of sophisticated pacing to younger patients (aged under 75). Further savings could be made by using the least expensive pacing models available. CONCLUSIONS--Implementing these recommendations should reduce morbidity related to bradyarrhythmia but will lead to major increases in pacing costs. Age and patients'' expected activity may be used to select simple pacing systems and thus to contain cost. More research is needed to determine which patient groups will benefit most from complex pacing systems.  相似文献   

12.
Right Ventricular Apical permanent pacing could have negative hemodynamic effects. A physiologic pacing modality should preserve a correct atrio-ventricular and interventricular synchronization. This can be obtained through biventricular pacing, left ventricular pacing, or from alternative right ventricular pacing sites. Direct His Bundle Pacing (DHBP) was documented as reliable and effective for preventing the desynchronization and negative effects of right ventricular apical pacing. It is, however, a complex method that requires longer average implant times, cannot be carried out on all patients and presents high pacing thresholds. On the contrary, the parahisian pacing, with simpler feasibility and reliability criteria, seems to guarantee an early invasion of the His-Purkinje conduction system, with a physiological ventricular activation, very similar to the one that can be obtained with direct His bundle pacing. We present our experience on 68 patients who underwent a permanent right ventricular pacing in hisian/parahisian region, for advanced AV block and narrow QRS. In the first 17 patients we performed a double-blind randomized controlled study, with two 6-months cross-over periods in parahisian and apical pacing, documenting a significant improvement of NYHA class, exercise tolerance, quality of life score, mitral and tricuspidal regurgitation degree, and interventricular mechanical delay. In the subsequent 51 patients, in a mean follow of 21 months/patient, the pacing threshold remained stable (0.7+/-0.5 V implant; 0.9+/-0.7 V follow-up; p=0.08). The ejection fraction maintained medium-long term stable values, confirming the fact that the parahisian pacing can prevent deterioration of the left ventricular function. Parahisian pacing, therefore, has proven to be a reliable method, easy to apply and effective in preventing the negative effects induced by non-physiological right ventricular apical pacing.  相似文献   

13.
This study aims to observe the effects of ibutilide on canine cardiac pacing threshold and on induction rates of atrial fibrillation. Eighteen mongrel dogs were anesthetized and administrated with ibutilide. The pacing thresholds and induction rates of atrial fibrillation were measured with and without ibutilide (10-min infusion dose was 0.10?mg?kg?1, followed by a maintaining dose of 0.01?mg?min?1 30?min later). This study found that ibutilide increases pacing thresholds in dogs. Moreover, there were significant differences between pacing thresholds with and without ibutilide (P?<?0.05). Further, ibutilide significantly reduces the induction rates of atrial fibrillation (P?<?0.05). Our findings indicate that pacing voltage changes should be closely monitored in patients taking anti-arrhythmic drugs, who are treated with cardiac stimulation or have undergone pacemaker implantation. We also found that ibutilide is an effective drug in preventing or controlling atrial fibrillation.  相似文献   

14.
目的分析并总结采用临时起搏器在实施经皮冠状动脉介入术治疗高风险冠状动脉病变中的应用效果。方法回顾性分析在临时起搏器支持下实施PCI的18例高危病人的临床资料,分析临时起搏器置入以及冠脉介入的操作情况。结果本组病人置入临时起搏电极起搏成功率达到100%。结论联合应用临时起搏器与经皮冠脉介入术治疗急性心肌梗死(AMI)与慢性血管闭塞性病变患者,能够降低经皮冠脉介入术治疗中由于严重心律失常导致的血液动力学改变,使病人尽快恢复正常心率以及各主要脏器的供血,减少患者的病死率,具有较高的安全性,值得在临床上广泛推广应用。  相似文献   

15.

Background

Dual chamber pacing improves functional status and reduces left ventricular outflow tract gradients in some, but not all patients with hypertrophic cardiomyopathy (HCM) by altering ventricular depolarisation. We investigated the use of biventricular (BIV) pacing in symptomatic patients with HCM.

Method

8 patients aged 58±7yrs with symptomatic HCM underwent BIV pacing. 5 patients had LVOT gradients >30mmHg. Ventricular electrodes were placed in the right ventricle (RV) and a branch of the coronary sinus. An atrial electrode was inserted to achieve BIV pacing with a short AV delay. The short-term effects of different pacing modalities were assessed using 2-D and Doppler echocardiography. Symptoms and exercise tolerance were assessed after a month of each pacing mode. Long-term follow up data was available for 5 years.

Results

Baseline EF was 67±14% and mean QRS duration was 132±26msecs. BIV pacing reduced QRS duration compared to RV pacing (129±46 vs. 205±54msecs, p<0.005). Five of the seven patients had baseline LVOT gradients (mean 67±25mmHg) that decreased to 41±15mm Hg with RV pacing (p<0.01) and 25±15mmHg with BIV pacing (p<0.005). Improvements in exercise time with active pacing occurred in six out of eight patients (75%), three (37.5%) had optimal exercise times with RV pacing and three with BIV pacing. Of the three patients with short term improvements with BIV pacing, one died 4 years post implant, one deteriorated with LV dilatation and one had the system explanted for infection.

Conclusion

BIV pacing showed short-term beneficial effects in some patients over and above RV pacing alone.  相似文献   

16.
目的:研究模拟野战条件下在自主创新研制介入方舱内行,临时起搏实验的可行性和时效性。方法:对5例正常狗在微创介入方舱内使用普通电极导管进行急诊心脏临时起搏模拟操作,观察该过程的时间,和操作效果,以及舱内人员的配合。结果:应用普通电极导管急诊心脏超速起搏5例全部成功,股静脉穿刺,无穿刺部位血肿、感染,血栓栓塞,心脏穿孔等并发症发生。时间在10分钟以内。结论:依托微创介入方舱,在野外恶劣条件下进行临时起搏的急救过程安全,实用,快捷。可用于战时以及非战争卫勤急救任务中,发挥重要作用。  相似文献   

17.
目的:研究模拟野战条件下在自主创新研制介入方舱内行临时起搏实验的可行性和时效性。方法:对5例正常狗在微创介入方舱内使用普通电极导管进行急诊心脏临时起搏模拟操作,观察该过程的时间,和操作效果,以及舱内人员的配合。结果:应用普通电极导管急诊心脏超速起搏5例全部成功,股静脉穿刺,无穿刺部位血肿、感染,血栓栓塞,心脏穿孔等并发症发生。时间在10分钟以内。结论:依托微创介入方舱,在野外恶劣条件下进行临时起搏的急救过程安全,实用,快捷。可用于战时以及非战争卫勤急救任务中,发挥重要作用。  相似文献   

18.
 The influence of subthreshold depolarizing prepulses on the threshold current-to-distance and the threshold current-to-diameter relationship of myelinated nerve fibers has been investigated. A nerve fiber model was used in combination with both a simple, homogeneous volume conductor model with a point source and a realistic, inhomogeneous volume conductor model of a monofascicular nerve trunk surrounded by a cuff electrode. The models predict that a subthreshold depolarizing prepulse will desensitize Ranvier nodes of fibers in the vicinity of the cathode and thus cause an increase in the threshold current of a subsequent pulse to activate these fibers. If the increase in threshold current of the excited node is large enough, the excitation will be accompanied by a strong hyperpolarization of adjacent nodes, preventing the propagation of action potentials in these fibers. As fibers close to the electrode are more desensitized by prepulses than more distant ones, it is possible to stimulate distant fibers without stimulating such fibers close to the electrode. Moreover, as larger fibers are more desensitized than smaller ones, smaller fibers have lower threshold currents than larger fibers up to a certain distance from the electrode. The realistic model has provided an additional condition for the application of this method to invert nerve fiber recruitment, i.e., real or virtual anodes should be close to the cathode. When using a cuff electrode for this purpose, in the case of monopolar stimulation the cuff length (determining the position of the virtual anodes) should not exceed twice the internodal length of the fibers to be blocked. Similarly, the distance between cathode and anodes should not exceed the internodal length of these fibers when stimulation is to be applied tripolarly. Received: 15 May 2000 / Accepted in revised form: 9 February 2001  相似文献   

19.
BACKGROUND: Advances in endocardial device design have been limited by the inability to visualize the device-tissue interface. The purpose of this study was to assess the validity of an isolated heart approach, which allows direct ex vivo intracardiac visualization, as a research tool for studying endocardial pacing systems. METHOD OF APPROACH: Endocardial pacing leads were implanted in the right atria and ventricles of intact swine (n = 8) under fluoroscopic guidance. After collection of pacing and sensing performance parameters, the hearts were excised with the leads intact and reanimated on the isolated heart apparatus, and parameters again recorded. RESULTS: Atrial ex vivo parameters significantly decreased compared with in vivo measurements: P-wave amplitudes by 39%, slew rates by 61%, and pacing impedances by 42% (p < 0.05 for each). Similarly, several ventricular ex vivo parameters decreased: R-wave amplitudes by 39%, slew rates by 62%, and pacing impedances by 31%. In contrast, both atrial (4.4 +/- 2.8 vs 3.3 +/- 2.8 V; p = ns) and ventricular thresholds increased (1.2 +/- 0.7 vs 0.6 +/- 0.1 V; p < 0.05 for all). Three distinct phenomena were observed at the lead-tissue interface. Normal implants (70%) demonstrated minimal tissue distortion and resulted in elevated impedance and threshold values. Three implants (13%) resulted in severe tissue distortion and/or tissue wrapping and were associated with highly elevated pacing parameters. Tissue coring occurred in four implants (17%) where the lead would spin freely in the tissue after overtorquing of the lead. CONCLUSIONS: The utility of the isolated heart approach was demonstrated as a tool for the design and assessment of the performance of endocardial pacing systems. Specifically, the ability to visualize device-heart interactions allows new insights into the impact of product design and clinical factors on lead performance and successful implantation.  相似文献   

20.
A modified pacemaker lead that can be inserted by percutaneous puncture of the subclavian vein, as in the Seldinger technique, has been designed for permanent cardiac pacing. Its use may be advantageous when isolation of an adequate vein for electrode insertion is difficult or impossible.  相似文献   