首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A rapid, sensitive, and highly selective liquid chromatography-tandem mass spectrometry method was developed and validated for simultaneous determination of enalapril and its major active metabolite enalaprilat in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Zorbax Extend-C(18) column, and detected by tandem mass spectrometry with a Turbo IonSpray ionization interface. The method has a lower limit of quantification (LLOQ) of 0.1 ng/ml for both enalapril and enalaprilat. The chromatographic run time was approximately 3.5 min. The standard calibration curves for both enalapril and enalaprilat were linear in the concentration ranges of 0.10-100.0 ng/ml in human plasma. The intra- and inter-run precisions, expressed as the relative standard deviation (R.S.D.), were less than 7.7 and 7.8%, determined from QC samples for enalapril and enalaprilat, and accuracy was within +/-3.9 and +/-2.7% in terms of relative error, respectively. The method was successfully applied for the evaluation of the pharmacokinetics of enalapril and enalaprilat in 20 volunteers after an oral dose of 10 mg enalapril maleate.  相似文献   

2.
Gemcitabine-squalene is a new prodrug that self-organizes in water forming nanoassemblies. It exhibits better anti-cancer properties in vitro and in vivo than gemcitabine. A liquid chromatography/tandem mass spectrometry assay of gemcitabine-squalene and gemcitabine was developed in human plasma in order to quantitate gemcitabine and its squalene conjugate. After protein precipitation with acetonitrile/methanol (90/10, v/v), the compounds were analyzed by reversed-phase high performance liquid chromatography and detected by tandem mass spectrometry using multiple reaction monitoring. The method was linear over the concentration range of 10-10,000 ng/ml of human plasma for both compounds with an accuracy lower than 10.4% and a precision below 14.8%. The method showed a lower limit of quantitation of 10 ng/ml of human plasma for dFdC and dFdC-SQ. A preliminary in vivo study in mice was shown as application of the method as no significant difference between human and mice plasma for the analysis of dFdC and dFdC-SQ was demonstrated.  相似文献   

3.
A selective and sensitive method has been developed and validated for simultaneous quantification of methylephedrine and noscapine in human plasma. Analytes were extracted from human plasma samples by liquid-liquid extraction, separated on a Diamonsil C18 column and detected by tandem mass spectrometer with an atmospheric pressure chemical ionization (APCI) interface. Diphenhydramine was used as the internal standard (I.S.). The method was found to be precise and accurate within the linear range 0.1-100 ng/ml for each analyte. The intra- and inter-day relative standard deviations (R.S.D.s) were below 5.2% for methylephedrine and 6.7% for noscapine. The inter-day relative error (RE) as determined from quality control samples (QCs) was less than 3.0% for each analyte. The assay was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation containing 20 mg DL-methylephedrine hydrochloride, 16 mg noscapine, 300 mg paracetamol and 1mg of chlorpheniramine maleate.  相似文献   

4.
A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of triazolam and its metabolites, alpha-hydroxytriazolam (alpha-OHTRZ) and 4-hydroxytriazolam (4-OHTRZ), was developed and validated. Triazolam-D4 was used as the internal standard (IS). This analysis was carried out on a Thermo((R)) C(18) column and the mobile phase was composed of acetonitrile:H(2)O:formic acid (35:65:0.2, v/v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer using positive ion mode electrospray ionization (ESI) and quantification was performed by multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 343.1-->308.3, 359.0-->308.3, 359.0-->111.2 and 347.0-->312.0 for triazolam, alpha-OHTRZ, 4-OHTRZ and triazolam-D4, respectively. LLOQ of the analytical method was 0.05ng/mL for triazolam and 0.1ng/mL for alpha-OHTRZ and 4-OHTRZ. The within- and between-run precisions were less than 15.26% and accuracy was -8.08% to 13.33%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of triazolam in healthy Chinese volunteers.  相似文献   

5.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous estimation of hydrochlorothiazide, quinapril and its metabolite quinaprilat in human plasma. After solid phase extraction (SPE), the analytes and IS were chromatographed on a hypurity C8 (100mmx2.1mm i.d., 5mum particle size) column using 2muL injection volume with a run time of 2.8min. An isocratic mobile phase consisting of 0.5% (v/v) formic acid:acetonitrile (25:75, v/v) was used to separate all these drugs. The precursor and product ions of these drugs were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring mode (MRM) without polarity switch. The proposed method was validated over the range of 5-500ng/mL for hydrochlorothiazide method and 5-1500ng/mL for quinapril and quinaprilat. Inter-batch and intra-batch precision (coefficient of variation - % CV) across five validation runs lower limit of quantitation (LLOQ), lower quality control (LQC), middle quality control (MQC), higher quality control (HQC) and upper limit of quantitation (ULOQ) was less than 15. The accuracy determined at these levels was within +/-13% in terms of relative percentage error.  相似文献   

6.
A selective and sensitive method for the simultaneous determination of hypericin and hyperforin--the two main active ingredients of St. John's Wort (SJW) extract--in human plasma depending on liquid/liquid-extraction and LC/MS/MS detection has been developed, validated after specifying the stability of the photosensitive hypericin in plasma samples during light exposure and applied to samples of a patient. After extraction with ethyl acetate/n-hexane in the darkness, sample extracts were chromatographed isocratically within 6 min on a Kromasil RP-18 column. The analytes were detected with tandem mass spectrometry in the selected reaction monitoring mode using an electrospray ion source. The limit of quantification was 0.05 ng/mL for hypericin and 0.035 ng/mL for hyperforin. The accuracy of the method varied between 101.9 and 114.2% and the precision ranged from 4.7 to 15.4% (S.D., batch-to-batch) for both analytes. The method was linear at least between 0.05 and 10 ng/mL for hypericin and between 0.035 and 100 ng/mL for hyperforin. Using this method hypericin and hyperforin were determined successfully in a patient over seven days following discontinuation of exposure with therapeutic doses of St. John's Wort extract.  相似文献   

7.
A quantitative assay method by liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) for the simultaneous determination of azelnidipine and its two metabolites, M-1 (aromatized form) and M-2 (hydroxylated form), in human plasma was developed and validated. Plasma samples, each of 1.0mL, were extracted by a single step liquid-liquid extraction using a mixture of ethyl acetate and hexane (1:1, v/v), and analyzed by the LC/ESI-MS/MS method. Three analytes were separated by isocratic elution on a C(18) column, and ionized using a positive ion electrospray ionization source. The ion transitions were monitored in selected reaction monitoring (SRM) mode. The chromatographic run time was 11min per injection, with retention time of 3.6, 10.2 and 6.8min for azelnidipine, M-1 and M-2, respectively. The calibration curves for azelnidipine, M-1 and M-2 well fitted to equations by a weighted (1/X(2)) quadratic regression over the range of 0.5-40.0ng/mL (r(2)>0.9979). The intra- and inter-assay precisions (coefficient of variation: C.V.), calculated from quality control (QC) samples, were less than 8.7 and 8.4%, 3.8 and 4.7%, and 11.9 and 13.9%, respectively, for azelnidipine, M-1 and M-2. The accuracy was within +/-9% for azelnidipine, within +/-7% for M-1 and within +/-16% for M-2. The overall recoveries for azelnidipine, M-1 and M-2 were 68.8-78.6%, 54.3-62.9% and 80.4-89.7%, respectively. All analytes evaluated demonstrated acceptable short-term, long-term, auto-sampler and stock solution stabilities. Furthermore, the method developed was successfully applied to pharmacokinetic studies on azelnidipine, M-1 and M-2 after an oral dose of 16mg CALBLOCK tablets (2mgx8mg tablets) to healthy volunteers.  相似文献   

8.
We developed a method for determining ebastine, a new generation of antihistamines, and its three metabolites (hydroxyebastine, carebastine and desalkylebastine) in plasma simultaneously using LC/MS/MS. Four compounds and terfenadine, an internal standard, were extracted from plasma using a mixture of diethylether and dichloromethane in the presence of 1 M HCl. After drying the organic layer, the residue was reconstituted in mobile phase (acetonitrile:5 mM ammonium acetate, 50:50, v/v) and injected onto a reversed-phase C(18) column. The isocratic mobile phase was eluted at 0.2 ml/min. The ion transitions monitored in multiple reaction-monitoring mode were m/z 470.7-->167.1, 486.7-->167.1, 500.6-->167.1, 268.4-->167.1 and 472.7-->436.0 for ebastine, hydroxyebastine, carebastine, desalkylebastine and terfenadine, respectively. The coefficient of variation of the assay precision was less than 12.5%, and the accuracy exceeded 88%. The limit of detection was 0.5 ng/ml for desalkylebastine; 0.2 ng/ml for ebastine, hydroxyebastine and carebastine, respectively. This method was used to measure the plasma concentration of ebastine and its three metabolites from healthy subjects after a single 20 mg oral dose of ebastine. This analytic method is a very simple, sensitive, and accurate to determine the pharmacokinetic profiles of ebastine including its metabolites.  相似文献   

9.
A sensitive and selective high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the determination of buagafuran in human plasma. The analyte was extracted from plasma samples with hexane after addition of isotopic internal standard and chromatographed on a RP-C(8) column. The mobile phase consisted of methanol-water (90:10, v/v) and the flow rate was 0.2 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reactions monitoring (MRM) mode using positive electrospray ionization (ESI). The method was validated over the concentration range of 0.5-200 ng/mL. Inter- and intra-day precision (RSD%) were all within 15% and the accuracy (RE%) was equal or lower than 9.5%. The lower limit of quantitation (LLOQ) was 0.5 ng/mL. The extraction recovery was on average 38.1% and the detection was not affected by the matrix. The method was successfully applied to the pharmacokinetic study of buagafuran in healthy Chinese volunteers.  相似文献   

10.
A simple procedure for the measurement of stability of drug candidates in plasma was developed to eliminate the traditional labor-intensive and time-consuming sample preparation procedures that are typically used for these studies. The procedure makes use of a thermostatic autosampler as an incubator combined with the direct plasma injection method based on high-performance liquid chromatography (HPLC) coupled to tandem mass spectrometry (MS-MS). Untreated human, monkey, mouse and rat plasma containing the test compound was directly injected into a mixed-function column for on-line protein removal and chromatography. The test compound and its biotransformation product were separated via HPLC and monitored using the tandem mass spectrometer. The need for adequate chromatographic separation of the test compound (M) from its carboxylic acid metabolite (M+1) is demonstrated. Plasma samples from four different species at specified incubation temperatures were sequentially assayed in one analytical procedure. The injection-to-injection time was about 6 min. The peak responses of the test compound in individual plasma samples were repeatedly determined every 24 min. The retention times and peak shape of all analytes were found to be consistent throughout the experiments. The stability of the test compound in plasma was found to be a function of animal species, incubation time and temperature. The test compound was rapidly degraded in rat plasma at 37 degrees C, but it could be stabilized by adding sodium thiosulfate.  相似文献   

11.
A liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method without sample pretreatment was developed and validated for determination of porphyrins in samples of canine urine. Acidified urine samples were directly injected into the LC-MS system and a gradient elution program was applied. The mass spectrometer was operated in the multi-reaction monitoring (MRM) mode and six porphyrins were detected with excellent sensitivity and selectivity. The lower limits of quantification were 0.014 nmol/mL for mesoporphyrin IX, coproporphyrin I, 5-carboxylporphyrin, 6-carboxylporphyrin and 7-carboxylporphyrin, and 0.029 nmol/mL for uroporphyrin I. Good ln-quadratic responses of calibration standards over the range 0.01 to 1.0 nmol/mL for mesoporphyrin IX, coproporphyrin I, 5-carboxylporphyrin, 6-carboxylporphyrin and 7-carboxylporphyrin, and 0.02 to 1.0 nmol/mL for uroporphyrin I were demonstrated. This method should be easily adapted through cross-validation for use in determining the effects of chemicals and pharmaceuticals on the urinary excretion profile of porphyrins in preclinical studies with other species, and in assisting the diagnosis of porphyria in clinical studies.  相似文献   

12.
A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method is described for quantitation of metformin in human plasma. After a simple, one-step protein precipitation using acetonitrile, metformin and the internal standard diphenhydramine were chromatographed on a C(8) column and detected by tandem mass spectrometry. An atmospheric pressure chemical ionization interface was chosen to reduce ion suppression from sample matrix components and provide high sensitivity. The method has a chromatographic total run time of 3.4 min and was linear within the range 2-2000 ng/ml. Intra- and inter-day precision, expressed as the relative standard deviation (R.S.D.), ranged from 4.4 to 5.7% and from 1.3 to 2.8%, respectively. Assay accuracy was less than 1% in terms of %RE (relative error). The assay was used to evaluate the pharmacokinetics of metformin after an oral administration of multicomponent formulation containing 500 mg metformin and 2.5 mg glyburide to 20 healthy volunteers.  相似文献   

13.
A sensitive and enantioselective method was developed and validated for the determination of ondansetron enantiomers in human plasma using enantioselective liquid chromatography-tandem mass spectrometry. The enantiomers of ondansetron were extracted from plasma using ethyl acetate under alkaline conditions. HPLC separation was performed on an ovomucoid column using an isocratic mobile phase of methanol-5 mM ammonium acetate-acetic acid (20:80:0.02, v/v/v) at a flow rate of 0.40 mL/min. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, using the transitions of m/z 294-->170 for ondansetron enantiomers, and m/z 285-->124 for tropisetron (internal standard). The method was linear in the concentration range of 0.10-40 ng/mL for each enantiomer using 200 microL of plasma. The lower limit of quantification (LLOQ) for each enantiomer was 0.10 ng/mL. The intra- and inter-assay precision was 3.7-11.6% and 5.6-12.3% for R-(-)-ondansetron and S-(+)-ondansetron, respectively. The accuracy was 100.4-107.1% for R-(-)-ondansetron and 103.3-104.9% for S-(+)-ondansetron. No chiral inversion was observed during the plasma storage, preparation and analysis. The method was successfully applied to characterize the pharmacokinetic profiles of ondansetron enantiomers in healthy volunteers after an intravenous infusion of 8 mg racemic ondansetron.  相似文献   

14.
A sensitive and simple method was developed for determination of the enantiomers of azelnidipine, (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, in human plasma using chiral liquid chromatography with positive ion atmospheric pressure chemical ionization tandem mass spectrometry. Plasma samples spiked with stable isotope-labeled azelnidipine, [(2)H(6)]-azelnidipine, as an internal standard, were processed for analysis using a solid-phase extraction in a 96-well plate format. The azelnidipine enantiomers were separated on a chiral column containing alpha(1)-acid glycoprotein as a chiral selector under isocratic mobile phase conditions. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, monitoring the transitions from m/z 583-->167 for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, and from m/z 589-->167 for [(2)H(6)]-azelnidipine. The standard curve was linear over the studied range (0.05-20 ng/mL), with r(2)>0.997 using weighted (1/x(2)) quadratic regression, and the chromatographic run time was 5.0 min/injection. The intra- and inter-assay precision (coefficient of variation), calculated from the assay data of the quality control samples, was 1.2-8.2% and 2.4-5.8% for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine, respectively. The accuracy was 101.2-117.0% for (R)-(-)-azelnidipine and 100.0-107.0% for (S)-(+)-azelnidipine. The overall recoveries for (R)-(-)-azelnidipine and (S)-(+)-azelnidipine were 71.4-79.7% and 71.7-84.2%, respectively. The lower limit of quantification for both enantiomers was 0.05 ng/mL using 1.0 mL of plasma. All the analytes showed acceptable short-term, long-term, auto-sampler and stock solution stability. Furthermore, the method described above was used to separately measure the concentrations of the azelnidipine enantiomers in plasma samples collected from healthy subjects who had received a single oral dose of 16 mg of azelnidipine.  相似文献   

15.
D-erythro-sphingosine (Sph) and its phosphorylated product, d-erythro-sphingosine 1-phosphate (S1P) are sphingolipids mediating numerous cellular processes. Imbalance of Sph/S1P levels contributes to many diseases. Given the interconversion of these two opposing signaling molecules, it is essential to examine their levels simultaneously. In the present study, we developed a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to simultaneously quantify the levels of Sph and S1P in biological samples using C17-Sph and C17-S1P as internal standards. With one step of methanol-induced protein precipitation, each sample was subjected to LC-MS/MS analysis using positive electrospray ionization under selected reaction monitoring mode. The running time was within 4 min with a simple mobile phase consisting of methanol-0.1% formic acid (95:5, v/v) at a flow rate of 0.2 mL/min. Standard curves were linear over ranges of 1-100 ng/mL for Sph and 0.1-10 ng/mL for S1P with correlation coefficient (r2) greater than 0.997. The lower limit of quantifications (LLOQs) were 1 ng/mL for Sph and 0.1 ng/mL for S1P. The intra-batch and inter-batch precision was less than 15% for all quality control samples. The recoveries of the method were found to be 76.36-89.84%. The method was applied to simultaneously determine the Sph and S1P levels in mouse kidney, human plasma, and HEK 293 cells treated with tumor necrosis factor-α (TNF-α) and N,N-dimethylsphingosine (DMS). The S1P levels increased in cells treated with TNF-α whereas decreased in cells treated with DMS. These results indicated that this new LC-MS/MS method was rapid, sensitive, specific and reliable to quantify Sph and S1P levels in biological samples simultaneously.  相似文献   

16.
A rapid, sensitive and reliable method was developed to quantitate omeprazole in human plasma using liquid chromatography-tandem mass spectrometry. The assay is based on protein precipitation with acetonitrile and reversed-phase liquid chromatography performed on an octadecylsilica column (55 mm x 2mm, 3 microm particles), the mobile phase consisted of methanol-10 mM ammonium acetate (60:40, v/v). Omeprazole and flunitrazepam, the internal standard, elute at 0.80+/-0.10 min with a total run time 1.35 min. Quantification was through positive ion mode and selected reaction monitoring mode at m/z 346.1-->197.9 for omeprazole and m/z 314.0-->268.0 for flunitrazepam, respectively. The lower limit of quantitation was 1.2 ng/ml using 0.25 ml of plasma and linearity was observed from 1.2 to 1200 ng/ml. Within-day and between-day precision expressed by relative standard deviation was less than 5% and inaccuracy did not exceed 12%. The assay was applied to the analysis of samples from a pharmacokinetic study.  相似文献   

17.
A liquid chromatographic (LC)-tandem mass spectrometry (MS/MS) method was developed for simultaneous determination of stilbenes, diethylstilbestrol (DES), hexestrol (HEX), and dienoestrol (DEN) in animal tissue. Sample clean-up and analyte enrichment was performed by automated solid-phase extraction (ASPE) with a silica gel cartridge. Detection capabilities (CCbeta) related to the transition products of lowest abundance for the method were 0.04-0.45 ng g(-1) in tissue and were achieved using atmospheric pressure chemical ionization (APCI) in negative mode. The use of an internal standard in combination with the simplified sample preparation led to a sensitive and reliable analytical method. The recovery level of the method was 84-108% for DES and DEN between 0.5 and 5 ng g(-1), and 59-87% for HEX between 0.25 and 2.5 ng g(-1).  相似文献   

18.
A sensitive and selective liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantitative determination of microcystin-LR (MC-LR) and its glutathione conjugate (MC-LR-GSH) in fish tissues. The analytes were extracted from fish liver and kidney using 0.01M EDTA-Na(2)-5% acetic acid, followed by a solid-phase extraction (SPE) on Oasis HLB and silica cartridges. High-performance liquid chromatography (HPLC) with electrospray ionization mass spectrometry, operating in selected reaction monitoring (SRM) mode, was used to quantify MC-LR and its glutathione conjugate in fish liver and kidney. Recoveries of analytes were assessed at three concentrations (0.2, 1.0, and 5microg g(-1) dry weight [DW]) and ranged from 91 to 103% for MC-LR, and from 65.0 to 75.7% for MC-LR-GSH. The assay was linear within the range from 0.02 to 5.0microg g(-1) DW, with a limit of quantification (LOQ) of 0.02microg g(-1) DW. The limit of detection (LOD) of the method was 0.007microg g(-1) DW in both fish liver and kidney. The overall precision was determined on three different days. The values for within- and between-day precision in liver and kidney were within 15%. This method was applied to the identification and quantification of MC-LR and its glutathione conjugate in liver and kidney of fish with acute exposure of MC-LR.  相似文献   

19.
A sensitive liquid chromatography–tandem mass spectrometry method for the simultaneous determination of triclabendazole, its main metabolites (triclabendazole sulphone and triclabendazole sulphoxide) and a marker residue (ketotriclabendazole) in bovine and goat muscle, liver, and kidney samples is developed and validated. Analyte extraction from samples is effectively performed using liquid–liquid extraction by acetonitrile. Chromatographic separation is performed on a C18 reversed-phase column with gradient elution. The analytes are detected by tandem quadrupole mass spectrometry after positive electrospray ionization by multiple reaction monitoring. The limits of detection for analytes are found to be 0.25–2.5 μg/kg in muscle tissues and 1–10 μg/kg in liver and kidney tissues, respectively. The recoveries of edible bovine and goat tissues range from 84.9% to 109.5% when spiked at different levels with analytes, with relative standard deviations generally below 12.8%.  相似文献   

20.
1,5-Dicaffeoylquinic acid (1,5-DCQA), a potent HIV-1 integrase inhibitor, is undergoing an evaluation as a promising novel HIV therapeutic agent. Here, we report a simple, rapid and robust LC-MS/MS method for simultaneous determination of 1,5-DCQA and its two active metabolites, 1-caffeoyl-5-feruoylquinic acid (1,5-CFQA) and 1,5-O-diferuoylquinic acid (1,5-DFQA) in human plasma. The quantitation of the target compounds was determined by selected reaction monitoring (SRM) mode using electrospray ionization (ESI). Good linearity was obtained in the 3-500 ng/ml range for each analyte and the analytical method was validated in terms of specificity, precision, accuracy, recovery, stability and matrix effect. These assays gave R.S.D.% values for precision always lower than 13.8% and R.E.% values for accuracy between -8.9 and 0.9%. In addition, the specificity, extraction recovery, stability and matrix effect were satisfactory too. Using the measured plasma concentrations of 1,5-DCQA and its active metabolites in five healthy volunteers, pharmacokinetic profiles of 1,5-DCQA and its active metabolites were evaluated, which supported the clinical pharmacokinetic studies successfully. Due to its high sensitivity, specificity and simplicity, the method could be used for pharmacokinetic studies of both 1,5-DCQA and its active metabolite, and for routine monitoring of their levels in human plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号