 共查询到20条相似文献,搜索用时 15 毫秒
1.
A bidimensional HPLC method for the simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP) in bovine milk has been developed and validated. After centrifugation, aliquots (150 microl) of milk samples were directly injected to a column-switching HPLC system. At the first step a RAM octyl-BSA column was employed to automatically remove proteins that otherwise would interfere with milk analysis. The mobile phase 0.01 M phosphate buffer pH 6.0:acetonitrile (95:5, v/v) was used in the first 5 min for the elution of milk proteins and then 0.01 M phosphate buffer pH 6.0:acetonitrile (83:17, v/v) for transfer SMX and TMP to the analytical column. The separation of SMX and TMP from one another and from other remaining milk components was performed on an octyl column using the mobile phase 0.01 M phosphate buffer pH 5.0:acetonitrile (82:18, v/v), which were detected by UV at 265 nm. The calibration graphs were linear in the concentration ranges of 25-800 ng/ml and 50-400 ng/ml for SMX and TMP, respectively. The intra- and inter-assay coefficients of variation were less than 15% for both drugs. The validated method was applied to the analysis of milk samples of twelve (two groups of six) cows after administration (intramuscular or subcutaneous) of a single recommended therapeutic dose of the SMX-TMP combination.  相似文献   

2.
A sensitive and selective high-performance liquid chromatographic (HPLC) method with ultra-violet detection has been developed and validated for the simultaneous determination of posaconazole and voriconazole, two systemic anti-fungal agents. An internal standard diazepam was added to 100 microL of human plasma followed by 3 mL of hexane-methylene chloride (70:30, v/v). The organic layer was evaporated to dryness and the residue was reconstituted with 100 microL of mobile phase before being injected in the chromatographic system. The compounds were separated on a C8 column using sodium potassium phosphate buffer (0.04 M, pH 6.0): acetonitrile:ultrapure water (45:52.5:2.5, v/v/v) as mobile phase. All compounds were detected at a wavelength of 255 nm. The assay was linear and validated over the range 0.2-10.0 mg/L for voriconazole and 0.05-10.0 mg/L for posaconazole. The biases were comprised between -3 and 5% for voriconazole and -2 and 8% for posaconazole. The intra- and inter-day precisions of the method were lower than 8% for the routine quality control (QC). The mean recovery was 98% for voriconazole and 108% for posaconazole. This method provides a useful tool for therapeutic drug monitoring.  相似文献   

3.
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 °C and the residue was reconstituted with the mobile phase. 5 μL of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm × 150 mm, I.D. 5 μm, Agilent TC-C(18) column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 → 248.2m/z for azatadine, 383.3 → 337.3m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values.  相似文献   

4.
A rapid and simple HPLC method with UV detection (288 nm) was developed and validated for quantitation of niflumic acid in human plasma, the active metabolite of talniflumate. After precipitation with 100% methanol containing the internal standard, indomethacin, the analysis of the niflumic acid level in the plasma samples was carried out using a reverse phase C18 CAPCELL PAK (5 microm, 4.6 mm x 250 mm) column. The chromatographic separation was accomplished with an isocratic mobile phase consisting of a mixture of 0.1M sodium acetate in water and acetonitrile (37:63, v/v), adjusted to pH 6.4. This HPLC method was validated by examining its precision and accuracy for inter- and intra-day runs in a linear concentration range of 0.02-5.00 microg/mL. Stability of niflumic acid in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method was successfully applied to the bioequivalence study of talniflunate in healthy volunteers.  相似文献   

5.
A rapid and sensitive liquid chromatography-tandem mass spectrometric (LC-MS-MS) method for the determination of metformin in human plasma using phenformin as internal standard has been developed and validated. Sample preparation of plasma involved acidification with acetic acid, deproteination with acetonitrile and washing with dichloromethane. Samples were then analyzed by HPLC on a short Nucleosil C18 column (5 microm, 50 mm x 4.6 mm i.d.) using a mobile phase consisting of acetonitrile:methanol:10mM ammonium acetate pH 7.0 (20:20:60, v/v/v) delivered at 0.65 ml/min. Detection was performed using an Applied Biosystems Sciex API 4000 mass spectrometer set at unit resolution in the multiple reaction monitoring (MRM) mode. Atmospheric pressure chemical ionization (APCI) was used for ion production. The assay was linear over the range 1-2000 ng/ml with intra- and inter-day precision of <8.6% and accuracy in the range 91-110%. The limit of detection was 250 pg/ml in plasma. The method was successfully applied to a clinical pharmacokinetic study of an extended-release tablet of metformin hydrochloride (500 mg) administered as a single oral dose.  相似文献   

6.
A simple, sensitive and selective HPLC method with UV detection (315 nm) was developed and validated for quantitation of entacapone in human plasma, the newest addition to the group of antiparkinsonian agents. Following a single-step liquid-liquid extraction (LLE) with ethyl acetate/n-hexane (30/70, v/v), the analyte and internal standard (rofecoxib) were separated using an isocratic mobile phase of 30 mM phosphate buffer (pH 2.75)/acetonitrile (62/38, v/v) on a reverse phase C18 column. The lower limit of quantitation was 25 ng/mL, with a relative standard deviation of less than 8%. A linear range of 25-2500 ng/mL was established. This HPLC method was validated with between-batch and within-batch precision of 2.2-4.2% and 1.7-7.8%, respectively. The between-batch and within-batch accuracy was 98.7-107.5% and 97.5-106.0%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of entacapone in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is sensitive, simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   

7.
A simple high-performance liquid chromatographic (HPLC) method has been developed for the determination of epimedin C in rat plasma and applied to a pharmacokinetic study in rats after administration of Herba Epimedii extract. After addition of carbamazepine as an internal standard plasma samples were extracted with ethyl acetate. HPLC analysis of the extracts was performed on a Hypersil ODS2 analytical column using acetonitrile -0.4% acetic acid (25:75, v/v) as the mobile phase. The UV detector was set at 260 nm. The standard curve was linear over the range 0.05-4.0 microg/mL. The lower limit of quantification was 0.05 microg/mL. The HPLC method developed could be easily applied to the determination and pharmacokinetic study of epimedin C in rat plasma after giving the animals Herba Epimedii extract.  相似文献   

8.
A sensitive and reproducible high-performance liquid chromatography (HPLC)-UV method for the determination of Z24, a tumorigenesis and angiogenesis inhibitor, has been developed and validated in mouse whole blood. Blood samples were extracted with ether, evaporated, and the residue was reconstituted in mobile phase. An aliquot was separated by isocratic reversed-phase HPLC on a Hypersil ODS-2 column and quantified using UV detection at 390nm. The mobile phase was 50% (v/v) acetonitrile/water with a flow rate of 0.8ml/min. A linear curve over the concentration range of 0.05-6mug/ml (r(2)=0.9976) was obtained. The coefficient of the variation for the intra- and inter-day precision ranged from 3.0 to 10.9% and 5.7 to 10.3%, respectively. The absolute recovery of Z24 was 89.2-108.5%. The method is simple, economical and sufficient for in vivo pharmacokinetic studies on Z24. Nonlinear pharmacokinetics was found in mice at doses from 20 to 80mg/kg.  相似文献   

9.
A quantitative liquid chromatographic-electrospray ionization mass spectrometry method for the determination of naltrexone and 6beta-naltrexol in guinea pig plasma has been developed and validated using naloxone as an internal standard. A single step precipitation-extraction technique was carried out to extract the plasma samples using acetonitrile:ethyl acetate (1:1, v/v). The chromatographic separation was performed on a C(18) column using a mobile phase consisting of 35:65 (v/v) acetonitrile:2 mM ammonium acetate with 0.01 mM ammonium citrate at a flow rate of 0.25 mL/min. The analyte was detected after positive electrospray ionization using selected ion monitoring (SIM) mode. The mean recoveries for naltrexone, naltrexol, and naloxone were 91.7, 89.3, and 99.0%, respectively. The lower limit of quantification (LLOQ) for naltrexone and 6beta-naltrexol was 1.25 ng/mL, and the limit of detection (LOD) was 0.75 ng/mL. The method was applied to a pharmacokinetic study in order to assess the drug disposition of naltrexone in guinea pigs.  相似文献   

10.
A high-performance liquid chromatography (HPLC) method was developed and validated for the determination of orientin in rabbit plasma using ultraviolet (UV) absorbance detection. Orientin is the active constituent of purified herbal extract (TRO PE) from the flower of Trollius chinensis Bunge. Protein precipitation was used as the sample preparation technique. A Diamonsil C18 column (150 mmx4.6 mm, 5 microm) was equilibrated with a mobile phase composed of 0.1% acetic acid/methanol/acetonitrile (80/5/15, v/v/v). The calibration curve of orientin in rabbit plasma was linear in the concentration range of 0.530-53.0 microg/mL. This validated method was successfully applied to a pharmacokinetic study in rabbits after the intravenous administrations of orientin and TRO PE at three different doses.  相似文献   

11.
The enantioselective high-performance liquid chromatography (HPLC) of three racemic 3-hydroxybenzodiazepines, oxazepam (Oxa), lorazepam (Lor), and temazepam (Tem), is a difficult operation because of the spontaneous chiral inversion in polar solvent. To solve this problem, we have developed an HPLC method based on a chiral Cyclobond I-2000 RSP column, maintained at 12 degrees C, and a reversed mobile phase (acetonitrile in 1% triethylamine acetate buffer, TEAA) at a flow rate of 0.4 ml/min. Peaks were detected by a photodiode-array detector at 230 nm for quantification and by an optical rotation detector for identification of (+) and (-) enantiomers. The results showed that peak resolutions of Oxa, Lor, and Tem enantiomers, analyzed under the same conditions, were 3.2, 2.0, and 1.8, respectively. For the determination of Oxa enantiomers in plasma of rabbits, extraction with diethyl ether at pH 1.5, a polar organic mobile phase, and a Cyclobond I-2000 SP column were used. Other analytical conditions were the same as previously described. Blood samples were immediately cooled at 4 degrees C and centrifuged at 0 degrees C for the collection of plasma. The results showed a difference in plasma S(+)- and R(-)-oxazepam concentrations in rabbits. No racemization of S(+)- or R(-)-Oxa enantiomers, added alone to blank plasma, was observed after extraction and enantioselective HPLC analysis.  相似文献   

12.
A rapid high-pressure liquid chromatographic (HPLC) assay is described for the quantitative analysis of tolbutamide and its major metabolite, carboxy tolbutamide, in plasma. An aliquot (25–100 μl) of plasma was prepared for chromatography by deproteinization as follows. One volume of plasma and 2.5 volumes of acetonitrile were vortex mixed for a few seconds and then centrifuged for approx. 1 min. A 50-μl sample of the clear supernatant was injected into the chromatograph. A μBondapak C12 reversed-phase column was used with a mobile phase of acetonitrile-0.05% phosphoric acid (45:55) at a flow-rate of 1.5 ml/min. The column effluent was monitored by a variable-wavelength UV detector set at 200 nm. Tolbutamide and its metabolite had retention times of 5.75 and 3.25 min, respectively. The procedure yields reproducible results with sensitivity adequate for routine clinical monitoring of plasma levels or for single-dose pharmacokinetic studies. A number of commonly used drugs do not interfere with the method. A single plasma sample can be analyzed in approx. 9 or 10 min.  相似文献   

13.
A simplified method to determine clarithromycin concentrations in human plasma using protein precipitation in a 96-well plate and liquid chromatography-tandem mass spectrometry was developed and validated. Plasma proteins were precipitated with acetonitrile and roxithromycin was used as the internal standard. After vortex mixing and centrifugation, the supernatants were directly injected onto a Phenomenex Luna Phenyl-Hexyl column (50 mm x 2.0 mm ID, 3 microm). The mobile phase consisted of water and methanol (30:70, v/v) containing 0.1% formic acid and 5mM ammonium acetate. The flow rate was 0.22 mL/min and the total run time (injection to injection) was less than 3 min. Detection of the analytes was achieved using positive ion electrospray tandem mass spectrometry in selected reaction monitoring (SRM) mode. The linear standard curve ranged from 100 to 5000 ng/mL and the precision and accuracy (inter- and intra-run) were within 7.9% and 4.9%, respectively. The method was successfully used to determine clarithromycin concentrations in human plasma samples obtained from healthy subjects who were given clarithromycin 500 mg for 3 days. The method is rapid, simple, precise and directly applicable to clarithromycin pharmacokinetic studies.  相似文献   

14.
An isocratic high-performance liquid chromatographic (HPLC) method for simultaneous separation of the components in the antimalarial combination drug Malarone® with UV detection is described. An HPLC system using a mixed mode column composed of 50% C18 phase and 50% strong cation-exchanger has been optimised for the simultaneous separation of atovaquone, proguanil and its two main metabolites. The mobile phase was optimised for factors such as pH, counter ion concentration and acetonitrile. Elimination of interferences from other antimalarial drugs was achieved by adding sodium perchlorate to the mobile phase. With a mobile phase of acetonitrile-phosphate buffer (60:40, v/v) pH 6.8, 50.7 mmol l−1 K+ and 10 mmol l−1 Na·ClO4, separation was achieved within a run time shorter than 17 min.  相似文献   

15.
A simple, sensitive and selective HPLC method with UV detection (284 nm) was developed and validated for quantitation of rabeprazole in human plasma, the newest addition to the group of proton-pump inhibitors. Following solid-phase extraction using Waters Oasistrade mark SPE cartridges, the analyte and internal standard (Pantoprazole) were separated using an isocratic mobile phase of 5 mM ammonium acetate buffer (pH adjusted to 7.4 with sodium hydroxide solution)/acetonitrile/methanol (45/20/35, v/v) on reverse phase Waters symmetry C(18) column. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 8%. A linear range of 20-1000 ng/mL was established. This HPLC method was validated with between- and within-batch precision of 2.4-7.2% and 2.2-7.3%, respectively. The between- and within-batch bias was -1.7 to 2.6% and -2.6 to 2.1%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of rabeprazole in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 3 months storage in a freezer. This validated method is sensitive, simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   

16.
A sensitive high-performance liquid chromatographic method for a routine assay of nadolol in serum is described. Serum samples spiked with atenolol (internal standard) were extracted with diethyl ether. After centrifugation, the organic layer was evaporated to dryness. The residue was redissolved in the mobile phase and injected onto an octadecyl silica column (150 mm × 4.6 mm I.D.). The mobile phase was 0.05 M ammonium acetate (pH 4.5)—acetonitrile (85:15, v/v). Fluorometric detection (excitation 230 nm, emission 300 nm) was used. The minimum detectable level of nadolol in serum was 1 ng/ml.  相似文献   

17.
A sensitive and selective HPLC method with UV detection (290 nm) was developed and validated for quantitation of pantoprazole, proton-pump inhibitor, in human plasma. Following a single-step liquid-liquid extraction with methyl tert-butyl ether/diethyl ether (70/30, v/v), the analyte and internal standard (zonisamide) were separated using an isocratic mobile phase of 10mM phosphate buffer (pH 6.0)/acetonitrile (61/39, v/v) on reverse phase Waters symmetry C18 column. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 4%. A linear range of 20-5000 ng/mL was established. This HPLC method was validated with between-batch and within-batch precision of 1.3-3.2% and 0.7-3.3%, respectively. The between-batch and within-batch bias was -0.5 to 8.2 % and -2.5 to 12.1%, respectively. This validated method is sensitive and repeatable enough to be used in pharmacokinetic studies.  相似文献   

18.
Pyrazoloacridine (PZA) is a 9-methoxy substituted acridine with a reducible nitro group. PZA has shown selective solid tumor cytotoxicity with activity against hypoxic cells, non-cycling cells and cells expressing the multidrug resistant phenotype. A high-performance liquid chromatographic (HPLC) assay was developed and validated for the determination of PZA in human plasma to support phase II clinical trials. PZA and ethyl orange, the internal standard, were isolated from human plasma by precipitating plasma proteins with methanol, and centrifuging to pellet the proteins. The resulting supernatant was injected onto a cyanopropyl HPLC column eluted isocratically with a mobile phase consisting of 125 mM ammonium acetate buffer pH 4.75-acetonitrile (76:24, v/v). A single wavelength at 460 nm was used for detection. Relative standard deviations for the assay ranged from 5.0% to 12.2% for four different drug concentrations and the limit of quantitation was 100 ng/ml. During the validation short term stability of the drug in plasma and stability of PZA on repeated freezing and thawing of plasma was evaluated. Overall recovery of PZA was 88%. This simple assay was found suitable for studying the clinical pharmacokinetics of PZA.  相似文献   

19.
A highly sensitive and simple high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantification of dibenzoylmethane (DBM) in rat plasma. DBM and internal standard (I.S.) 1-(5-chloro-2-hydroxy-4-methylphenyl)-3-phenyl-1,3-propanedione (CHMPP) were extracted from rat plasma by ethyl acetate/methanol (95:5, v/v) and analyzed using reverse-phase gradient elution with a Phenomenex Gemini C18 5-mum column. A gradient of mobile phase (mobile phase A: water/methanol (80:20, v/v) with 0.1% TFA and mobile phase B: acetonitrile with 0.1% TFA) at a flow rate of 0.2 mL/min, and ultraviolet (UV) detection at 335 nm were utilized. The lower limit of quantification (LLOQ) using 50 microL rat plasma was 0.05 microg/mL. The calibration curve was linear over a concentration range of 0.05-20 microg/mL. The mean recoveries were 80.6+/-5.7, 83.4+/-1.6 and 77.1+/-3.4% with quality control (QC) level of 0.05, 1 and 20 microg/mL, respectively. Intra- and inter-day assay accuracy and precision fulfilled US FDA guidance for industry bioanalytical method validation. Stability studies showed that DBM was stable in rat plasma after 4h incubation at room temperature, one month storage at -80 degrees C and three freeze/thaw cycles, as well as in reconstitute buffer for 48 h at 4 degrees C. The utility of the assay was confirmed by the successful analysis of plasma samples from DBM pharmacokinetics studies in the rats after oral and intravenous administrations.  相似文献   

20.
Acyclovir [9-[(2-hydroxyethoxy)-methyl]-guanosine, Zovirax, ACV] is a synthetic purine nucleoside analog active against herpes simplex virus types 1 (HSV-1), 2 (HSV-2), and varicella zoster virus. Acyclovir has frequently been used in HSV-2 seropositive mothers to prevent prenatal transmission of herpes virus to their unborn children. A fast and reproducible HPLC method for the determination of the highly polar acyclvoir in maternal rat plasma, amniotic fluid, placental tissue, and fetal tissue has been developed and validated. Plasma and amniotic fluid samples were prepared by protein precipitation using 2 M perchloric acid and syringe filtering. Tissue samples were homogenized in distilled water, centrifuged, and extracted using a C(18) solid-phase extraction method prior to analysis. Baseline resolution was achieved for acyclovir and the internal standard gancyclovir, an anti-viral of similar structure to acyclovir, using an Agilent Eclipse XDB C(8) column (150 x 2.1 mm, 5 microm). The mobile phase used for the plasma and amniotic fluid was 10 mM acetate/citrate buffer-3.7 mM aqueous octanesulfonic acid (87.5:12.5, v/v) at a flow-rate of 0.2 ml/min. The mobile phase used for the tissue samples was 30 mM acetate/citrate buffer with 5 mM octanesulfonic acid-acetonitrile (99:1, v/v). Both aqueous mobile phase portions were pH adjusted to 3.08. All separations were done using an Agilent 1100 Series HPLC system with UV detection of 254 nm. The assay was validated for each matrix over a range of 0.25-100 microg/ml over 3 days using five replicates of three spiked concentrations. The relative standard deviation and percent error for each validation data set was <15% for middle and high quality control (QC) points and <20% for all low QC points. All calibration curves showed good linearity with an R(2)>0.99. The extraction efficiency for recovery of acyclovir from all matrices was >80%.  相似文献   