1.
The function of the recently described viscometric affinity sensor (VAS), which measures glucose due to its strong effect on the viscosity of a sensitive liquid containing Concanavalin A (ConA) and dextran, was analysed for osmotic and colloid-osmotic effects on the glucose reading. The suction of low- and high-molecular weight osmotica on the membrane of the microdialysis fibre was measured using a membrane osmometer built from the microdialysis probe of the VAS. The reduction of the sensor read-out in blood plasma can be completely explained by a change in small osmotic volume fluxes through the dialysis membrane, which affect the ConA concentration and the viscosity after the flow of the sensitive liquid through the dialysis probe. The measuring error could be prevented by the presence of the polyethylene glycol 6000 at an isotonic concentration in the glucose standard solutions used for sensor calibration.  相似文献   

2.
A device for continuous glucose monitoring in fluids was obtained by combining the microdialysis technique with a measuring flow chamber of the "Glucosensor Unitec Ulm" using the GOD method for determining amperometrically blood glucose profiles. The in vitro experiments demonstrate that the relative recovery of glucose by this device is inversely related to the flow rate of the microdialysis perfusion fluid, which, in turn, is inversely related to the response time of the device. The glucose signal increases linearly with the area of the microdialysis working membrane (r = 0.98), and with the glucose concentrations of the standard solutions (r greater than 0.95). The variation coefficient for repeated measurements is below 8%. The accuracy of the device as demonstrated by mean measuring deviation ranges between 1 and 3.8%.  相似文献   

3.
Although glucose sensors with millimolar sensitivity are still the norm, there is now a developing interest in glucose sensors with micromolar sensitivity for applications in minimally invasive sampling techniques such as fast microdialysis and extraction of interstitial fluid by iontophoresis and laser poration. In this regard, the glucose binding protein (GBP) with a binding constant for glucose in the micromolar range is of particular relevance. GBP is one of the soluble binding proteins found in the periplasmic space of Gram-negative bacteria. Because of its hinge-like tertiary structure, glucose binding induces a large conformational change, which can be used for glucose sensing by attaching a polarity sensitive fluorescent probe to a site on the protein that is allosterically responsive to glucose binding. Correspondingly, the resulting optical biosensor has micromolar sensitivity to glucose. Because binding is reversible, the biosensor is reusable and can be stored at 4 degrees C for 6 months without losing its sensitivity. In this paper, we show the feasibility of using the GBP biosensor to monitor glucose in microdialysis. The effect of perfusion rate, bulk glucose concentration and temperature on microdialysis efficiency was determined. Additionally, the glucose concentrations in mammalian cell culture were monitored to demonstrate the applicability of this sensor in complex and dynamic processes over a period of time. As the sensor is sensitive to micromolar glucose, high dialysis efficiency is not required when the bulk glucose concentration is within the millimolar physiological range. Thus, a perfusion rate of 10 microL/min or faster can be used, resulting in delay times of 1 min or less.  相似文献   

4.
A miniaturized on-line monitoring system for the detection of L-lactate and glucose is presented. The system is based on a microfabricated multi-enzyme silicon sensor chip with flow channels integrated on the chip. The sensors were fabricated in containment technology. They were characterized in test solutions. The cross-talking behaviour was investigated and was found to be practically negligible. The linear measurement ranges of both glucose and lactate sensors were large enough for most practical applications. As a result of the miniaturization the analyte consumption could be reduced to a few nmol min(-1). The system was equipped with a microdialysis probe whose recovery was 45% for lactate and 37% for glucose in test solutions using a flow rate of 3 microl min(-1). Lower flow rates of 0.5 microl min(-1) resulted in recoveries of over 90%. The long-term stability of the system was acceptable. Initial measurements have also been performed in vitro using human blood serum.  相似文献   

5.
Abstract: We have used a glucose oxidase-based sensor implanted in the striatum of freely moving rats to determine the concentration of extracellular glucose in two distinct ways. With a modification of the zero net flux method, in which different concentrations of glucose are infused through a dialysis probe glued to the biosensor, we calculated the concentration at which there was no change in glucose current by regression analysis; this gave a concentration of 0.351 ± 0.016 m M . Calculating the concentration from the basal current and the in vitro calibration of the biosensor was not significantly different from this. The basal extracellular glucose concentration determined by either method remained constant over a period of several days. Infusion of 50 µ M veratridine through the adjacent dialysis probe caused a steep decrease in glucose current as soon as the drug reached the brain in contrast to the delayed fall (7.5 min) seen with microdialysis in previous experiments from this laboratory. These results demonstrate that this biosensor provides a direct, real-time measure of the extracellular concentration of glucose.  相似文献   

6.
The abdominal subcutaneous interstitium is easily accessible for monitoring glucose for Diabetes Mellitus research and management. The available glucose sensing devices demand frequent blood sampling by finger pricking for calibration. Moreover, there is controversy about the exact relationship between the levels of glucose in the subcutis and blood. In the present study ultra-slow microdialysis was applied for subcutaneous fluid sampling, allowing continuous measurement of glucose in an equilibrated fluid using a nanolitre size sensor. The present method avoids in vivo calibration. During an oral glucose tolerance test glucose levels were measured simultaneously in blood, in adipose tissue and loose connective tissue layers of the abdominal subcutis in seven healthy subjects. Fasting glucose levels (mM) were 2.52 +/- 0.77 in adipose tissue and 4.67 +/- 0.17 in blood, this difference increasing to 6.40 +/- 1.57 and 11.59 +/- 1.52 at maximal glucose concentration. Moreover, the kinetics of glucose in blood and adipose tissue were different. In contrast, connective tissue glucose levels differed insignificantly (4.71 +/- 0.21 fasting and 11.70 +/- 1.96 at maximum) from those in blood and correlated well (r2 = 0.962). Ultra-slow microdialysis combined with a nanolitre glucose sensor could be of benefit to patients in intensive diabetes therapy. Frequent blood sampling for in vivo calibration can be avoided by monitoring glucose in the abdominal subcutaneous loose connective tissue, rather than in the adipose tissue.  相似文献   

7.
A small, removable microdialysis probe   总被引:4,自引:0,他引:4  
A miniaturized, concentric, microdialysis probe is described. It is constructed from 36 gauge stainless steel tubing inside of 26 gauge tubing, with a cellulose hollow fiber tip 0.2 mm in diameter and 2 mm long. It has a 6000 molecular weight cut off that excludes enzymes but collects monoamines, their metabolites, and other small neurochemicals. In vitro tests show relative recovery rates of 5-10%. Absolute recovery measured in picograms was independent of the perfusate flow rate inside the probe. Tests in awake rats with probes in the nucleus accumbens showed stable amounts of catecholamines and metabolites collected during repeated 20 min samples. After ip amphetamine, release of dopamine in the accumbens increased from 20 to 40 pg per sample while DOPAC and HVA decreased from about 1500 to 500 pg. Tests of multiple site sampling succeeded in obtaining norepinephrine and dopamine plus three metabolites (DOPAC, HVA and 5HIAA) from four probes simultaneously in four different brain sites in each rat. Five day continuous samples or monthly intermittent samples can be obtained with this microdialysis probe.  相似文献   

8.
The simultaneous on-line determination of glucose and lactate using a microdevice that consisted of a dialysis sampling system incorporated to the flow-through cell of a microfabricated biosensor array is presented. The fluidic connections between the different device's components were realized by subsequent processing of stacked dry resist layers on a plastic support that provided also the means for electric connections. The performance of the device was evaluated in vitro. The cross-talk effect on the downstream sensor was investigated and found to be negligible. Recoveries of over 95% for both analytes were achieved when flow rates of the perfusion fluid 相似文献   

9.
A biosensor system for continuous flow determination of enzyme activity was developed and applied to the determination of glucose oxidase and lactic dehydrogenase activities. The glucose oxidase activity sensor was prepared from the combination of an oxygen electrode and a flow cell. Similarly, the lactic dehydrogenase activity sensor was prepared from the combination of a pyruvate oxidase membrane, an oxygen electrode, and a flow cell. Pyruvate oxidase was covalently immobilized on a membrane prepared from cellulose triacetate, 1,8-diamino-4-aminomethyloctane, and glutaraldehyde. Glucose oxidase activity was determined from the oxygen consumed upon oxidation of glucose catalyzed by glucose oxidase. Lactic dehydrogenase activity was determined from the pyruvic acid formed upon dehydrogenation of lactic acid catalyzed by lactic dehydrogenase. The amount of pyruvic acid was determined from the oxygen consumed upon oxidation of pyruvic acid by pyruvate oxidase. Calibration curves for activity of glucose oxidase and lactic dehydrogenase were linear up to 81 and 300 units, respectively. One assay could be completed within 15 min for both sensors and these were stable for more than 25 days at 5°C. The relative errors were ±4 and ±6% for glucose oxidase and lactic dehydrogenase sensors, respectively. These results suggest that the sensor system proposed is a simple, rapid, and economical method for the determination of enzyme activities.  相似文献   

10.
Experimental and theoretical microdialysis studies of in situ metabolism   总被引:2,自引:0,他引:2  
Microdialysis sampling was performed to monitor localized metabolism in vivo and in vitro. A mathematical model that accounts for analyte mass transport during microdialysis sampling was used to predict metabolite concentrations in the microdialysis probe during localized metabolism experiments. The model predicts that metabolite concentrations obtained in the microdialysis probe are a function of different experimental parameters including membrane length, perfusion fluid flow rate, and sample diffusive and kinetic properties. Different microdialysis experimental parameters including membrane length and perfusion fluid flow rate were varied to affect substrate extraction efficiency (E(d)), or loss to the sample matrix, in vivo and in vitro. Local hepatic metabolism was studied in vivo in male Sprague-Dawley rats by infusing acetaminophen through the microdialysis probe. Acetaminophen sulfate concentrations increased linearly with respect to acetaminophen E(d) in contrast to modeling predictions. Xanthine oxidase was used as an in vitro model of localized metabolism. In vitro experimental results partially matched modeling predictions for 10-mm probes. These results suggest that monitoring local metabolism using microdialysis sampling is feasible. It is important to consider system parameters such as dialysis flow rate, membrane length, and sample properties because these factors will affect analyte concentrations obtained during local metabolism experiments.  相似文献   

11.
A wearable device for the continuous measurement of lactate in the blood was constructed by the combination of continuous blood sampling employing a double lumen catheter with an amperometric lactate sensor. In vitro, the lactate sensor turned out to have a linear concentration range between 0 and 15 mmol/l. The response time of the sensor itself amounted to 100 sec, whereas the lag time for blood sampling amounted to 2·2 min. In vivo, the lactate sensor was successfully used for the detection of changes of the blood lactate concentration following strenuous exercise in 7 healthy volunteers, in two cases up to 22 h. In conclusion, the technique of continuous blood sampling by the use of a double lumen catheter in combination with the amperometric lactate sensor is feasible and simplifies frequent blood lactate estimations.  相似文献   

12.
A high recovery microsampling probe based on microdialysis was devised. The new probe showed a high recovery (100%) of peptides in vitro at different perfusion flow rates (0.1-1.0 μl/min). At a high flow rate, 1.0 μl/min, a 10-fold increased in recovery of peptides compared to the conventional microdialysis probe was achieved. A probe made of a low molecular weight cutoff membrane is suitable for filtering off proteins. The new probe can be a useful tool for high recovery of peptides from living tissues.  相似文献   

13.
In vivo sampling of interstitial fluid by using microdialysis fibers has become a standard and accepted procedure. This sampling method is generally coupled to offline analysis of consecutive dialysate samples by high-performance liquid chromatography or capillary electrophoresis, but this combination is not the best approach for some applications, especially those which require high temporal resolution and rapid data collection. The purpose of this review is to provide information on enzyme-based online assays, i.e., continuous analysis of the dialysate as it emerges from the outlet of the sampling device. We have focused on methods developed specifically for the analysis of solutions perfused at a very slow flow rate, i.e., a feature of microdialysis and ultrafiltration techniques. These methods include flow enzyme-fluorescence assays, flow enzyme-amperometric assays, and sequential enzyme-amperometric detection. Each type of assay is discussed in terms of principle, applications, advantages, and limitations. We also comment on implantable biosensors, an obvious next step forward for in vivo monitoring of molecules in neuroscience.  相似文献   

14.
In vivo glucose monitoring is required for tighter glycaemic control. This report describes a new approach to construct a miniature implantable device based on a magnetic acoustic resonance sensor (MARS). A ≈ 600-800 nm thick glucose-responsive poly(acrylamide-co-3-acrylamidophenylboronic acid) (poly(acrylamide-co-3-APB)) film was polymerised on the quartz disc (12 mm in diameter and 0.25 mm thick) of the MARS. The swelling/shrinking of the polymer film induced by the glucose binding to the phenylboronate caused changes in the resonance amplitude of the quartz disc in the MARS. A linear relationship between the response of the MARS and the glucose concentration in the range ≈ 0-15 mM was observed, with the optimum response of the MARS sensor being obtained when the polymer films contained ≈ 20 mol% 3-APB. The MARS glucose sensor also functioned under flow conditions (9 μl/min) with a response almost identical to the sensor under static or non-flow conditions. The results suggest that the MARS could offer a promising strategy for developing a small subcutaneously implanted continuous glucose monitor.  相似文献   

15.
Glucose biosensors based on the use of planar screen-printed electrodes modified with an electrochemical mediator and with glucose oxidase have been optimised for their application in the continuous glucose monitoring in diabetic patients. A full study of their operative stability and temperature dependence has been accomplished, thus giving useful information for in vivo applications. The effect of dissolved oxygen concentration in the working solution was also studied in order to evaluate its effect on the linearity of the sensors. Glucose monitoring performed with serum samples was performed to evaluate the effect of matrix components on operative stability and demonstrated an efficient behaviour for 72 h of continuous monitoring. Finally, these studies led to a sensor capable of detecting glucose at concentrations as low as 0.04 mM and with a good linearity up to 2.0 mM (at 37 degrees C) with an operative stability of ca. 72 h, thus demonstrating the possible application of these sensors for continuous glucose monitoring in conjunction with a microdialysis probe. Moreover, preliminary in vivo experiments for ca. 20 h have demonstrated the feasibility of this system.  相似文献   

16.
During a 70-h fermentation of a lignocellulose hydrolysate, the ethanol produced was monitored on-line using a microdialysis probe as an in situ sampling device. The dialysate components were then separated in a column liquid chromatographic system and the ethanol was selectively detected by an amperometric alcohol biosensor. The result was compared with two off-line analysis methods: one chromatographic method with refractive index (RI) detection and one enzymatic method based on spectrophotometric detection. The two methods base on enzymes were shown to give lower values than the chromatographic method based on RI detection, which is discussed n terms of selectivity. The investigated on-line setup was found to be a flexible system for monitoring of fermentations, allowing a sampling frequency of at least 12 h(-1) and with a delay between sampling and detection of less than 5 min. (c) 1994 John Wiley & Sons, Inc.  相似文献   

17.
The microdialysis technique was used for following the glucose content of the extracellular subcutaneous (SC) fluid under varying blood glucose levels in rats. The glucose content in the microdialysis perfusion fluid was continuously analyzed by means of the measuring flow chamber of an ex vivo glucose monitor. In six ChBB rats blood glucose levels were varied between 40 mg/dl and 575 mg/dl by intravenous (IV) infusion of glucose and by SC injections of insulin, respectively. After a running-in period of about half an hour, the glucose content in the perfusion fluid was closely related to the blood glucose concentration (r > 0.92) up to a time period of 6 hrs. The "relative recovery" rate of glucose by the microdialysis probe in the SC tissue varied within the 6 experimental sessions. The relative recovery rate could be shown to be not dependent on the absolute blood glucose levels in the individual rat within the glucose concentration range tested.  相似文献   

18.
Pediatric diffuse intrinsic pontine gliomas are aggressive brainstem tumors that fail to respond to treatment. We hypothesize that the protective features of the pons may hinder chemotherapeutic agents from entering pontine tissue compared with cortical brain tissue. To test this hypothesis, we developed a unique nonhuman primate model using microdialysis, a continuous in vivo extracellular sampling technique, to compare drug exposure concurrently in pontine tissue, cortical tissue, CSF, and plasma after intravenous administration of chemotherapeutic agents. The surgical coordinates and approach for microdialysis cannula–probe placement were determined in 5 adult male rhesus monkeys (Macaca mulatta) by using MRI. Microdialysis cannulas–probes were implanted stereotactically in the brain, retrodialysis was performed to measure relative recovery, and a 1-h intravenous infusion of temozolomide was administered. Continuous microdialysis samples were collected from the pons and cortex over 4 h with concurrent serial plasma and CSF samples. Postsurgical verification of microdialysis cannula–probe placement was obtained via MRI in 3 macaques and by gross pathology in all 5 animals. The MRI-determined coordinates and surgical methodologies resulted in accurate microdialysis probe placement in the pons and cortex in 4 of the 5 macaques. Histologic examination from these 4 animals revealed negligible tissue damage to the pontine and cortical tissue from microdialysis. One macaque was maintained for 8 wk and had no deficits attributed to the procedure. This animal model allows for the determination of differences in CNS penetration of chemotherapeutic agents in the pons, cortex, and CSF after systemic drug administration.Abbreviations: DIPG, diffuse intrinsic pontine glioma; ECF, extracellular fluidPediatric diffuse intrinsic pontine gliomas (DIPG) are aggressive tumors that cannot be surgically resected due to their location, and are resistant to chemotherapeutic and radiation therapies. As a result, children with DIPG have a dismal prognosis with median survival less than one year from diagnosis. One hypothesis for the poor efficacy of treatment is that innate CNS protective features, such as the blood–brain barrier and the blood–CSF barrier, shield the brainstem to a higher degree given its critical functions, and isolate pontine gliomas from treatment. To test this hypothesis, we developed a nonhuman primate model in rhesus monkeys to evaluate pontine tissue pharmacokinetics by using microdialysis, a continuous in vivo extracellular sampling technique based on diffusion. Microdialysis is the ‘gold standard’ for in vivo sampling methodologies in the CNS, enabling the collection of extracellular tissue fluid via passive diffusion by using a semipermeable membrane probe.A nonhuman primate model demonstrating the feasibility of microdialysis sampling from cortical brain tissue with concurrent pharmacokinetic sampling during chemotherapeutic drug administration has previously been established,3-5,7 but there are no current animal models that measure drug penetration into the pons. The location of the pons deep within the brain, as well as the vital brainstem functions associated with the pons, present additional obstacles to accurate microdialysis probe placement and sample collection. The objectives of the current study were to develop imaging and surgical procedures for the accurate placement of a microdialysis probe within the pons of rhesus monkeys for sample collection, to establish a method to perform microdialysis simultaneously in multiple CNS regions, and to develop a mechanism to perform repeated microdialysis in the same areas with a single invasive surgical procedure. This model allows for the pharmacokinetic comparison of drug penetration into pontine tissue, in conjunction with cortical tissue, plasma, and CSF, after intravenous administration.  相似文献   

19.
We present a viscometric affinity biosensor for continuous monitoring of glucose in biological fluids such as blood and plasma. The sensing principle of this chemico-mechanical sensor is based upon the viscosity variation of a sensitive fluid with glucose concentration. Basically, this device includes both an actuating and a sensing piezoelectric diaphragms as well as a flow-resistive microchannel. In order to confine the sensitive fluid and allow glucose diffusion into the sensor, a free-standing alumina nanoporous membrane is also used as size-selective interface. Measurements carried out at nominal temperatures of 25 and 37 °C reveal that this sensor topology exhibits a high resolution in the current range of physiological blood glucose concentrations, i.e. 2-20 mM. In addition, complete reversibility was also demonstrated for at least 3 days. Finally, measurements performed in human blood serum confirm that this sensor fulfils all basic requirements for a use in continuous glucose monitoring of biological fluids.  相似文献   

20.
A xanthine oxidase hydroxyl radical (.OH)-generating system was created for sustained in vitro production of *OH. This assay was coupled with microdialysis sampling to elucidate the factors that influence microdialysis calibration during radical trapping. A *OH trapping agent, 4-hydroxybenzoic acid, was included either in the microdialysis perfusion fluid or in the medium external to the microdialysis probe. Xanthine oxidase enzymatic activity was reproducible and had an average activity measured by UV absorbance of produced uric acid of 0.037 +/- 0.005 deltaAU/min (n = 5). A considerable amount of variance in the rate and amount of the product, 3,4-dihydroxybenzoic acid (3,4-DHBA), was observed when one microdialysis probe was placed in the reaction mixture. When two microdialysis probes were placed in the reaction mixture, a greater rate and amount of 3,4-DHBA was observed. Different concentrations of 3,4-DHBA were obtained between quiescent and stirred systems.  相似文献   