首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
AimIn this study, the egs_cbct code’s ability to replicate an electronic portal imaging device (EPID) is explored.BackgroundWe have investigated head and neck (H&N) setup verification on an Elekta Precise linear accelerator. It is equipped with an electronic portal imaging device (EPID) that can capture a set of projection images over different gantry angles.Methods and materialsCone-beam computed tomography (CBCT) images were reconstructed from projection images of two different setup scenarios. Projections of an Anthropomorphic Rando head phantom were also simulated by using the egs_cbct Monte Carlo code for comparison with the measured projections.Afterwards, CBCT images were reconstructed from this data. Image quality was evaluated against a metric defined as the image acquisition interval (IAI). It determines the number of projection images to be used for CBCT image reconstruction.ResultsFrom this results it was established that phantom shifts could be determined within 2 mm and rotations within one degree accuracy using only 20 projection images (IAI = 10 degrees). Similar results were obtained with the simulated data.ConclusionIn this study it is demonstrated that a head and neck setup can be verified using substantially fewer projection images. Bony landmarks and air cavities could still be observed in the reconstructed Rando head phantom. The egs_cbct code can be used as a tool to investigate setup errors without tedious measurements with an EPID system.  相似文献   

2.

Aim

To investigate the clinical application of a technique for patient set-up verification in breast cancer radiotherapy based on a 3D surface image registration system.

Background

Accurate and reproducible patient set-up is a prerequisite to correctly deliver fractionated radiotherapy. Various approaches are available to verify and correct patient setup for 3D image acquisition in a radiation treatment room.

Materials and methods

The study analyzed the setup reproducibility of 15 patients affected by breast cancer and candidates for conformal radiotherapy by using the AlignRT system (VisionRT, London, UK). At the initial setup, electronic portal imaging device (EPID) images were compared with Digitally Reconstructed Radiographs (DRRs) and a reference three-dimensional (3D) surface image was obtained by AlignRT. Surface images were acquired prior to every subsequent setup procedure. The systematic and random errors along longitudinal and vertical directions were measured and compared for the two systems.

Results

The procedure for surface registration, image acquisition and comparison with the reference image took less than 1 min on average. The T test for systematic error showed no significant difference between the 2 verification systems along the longitudinal (p = 0.69) and vertical (p = 0.67) axes. The T-test for random error showed a significant difference between the 2 systems along the vertical axis (p = 0.05).

Conclusion

AlignRT is fast, simple, non-invasive and seems to be reliable in detecting patient setup errors. Our results suggest that it could be used to assess the setup reproducibility for breast cancer patients.  相似文献   

3.
PurposeWe investigated the usefulness of four-dimensional computed tomography (4DCT) performed before stereotactic body radiation therapy (SBRT) in determining the internal margins for peripheral lung tumors.Methods and MaterialsThe amplitude of the movement of a fiducial marker near a lung tumor measured using the maximum intensity projection (MIP) method in 4DCT imaging was acquired before the SBRT (AmpCT) and compared with the mean amplitude of the marker movement during SBRT (Ampmean) and with the maximum amplitude of the marker movement during SBRT (Ampmax) using a real-time tumor-tracking radiotherapy (RTRT) system with 22 patients.ResultsThere were no significant differences between the means of the Ampmean and the means of the AmpCT in all directions (LR, P = 0.45; CC, P = 0.80; AP, P = 0.65). The means of the Ampmax were significantly larger than the means of the AmpCT in all directions (LR, P < 0.01; CC, P = 0.03; AP, P < 0.01). In the lower lobe, the mean difference of the AmpCT from the mean of the Ampmax was 5.7 ± 8.0 mm, 12.5 ± 16.7 mm, and 6.8 ± 8.5 mm in the LR, CC, and AP directions, respectively.ConclusionsAcquiring 4DCT MIP images before the SBRT treatment is useful to establish the mean amplitude for a patient during SBRT but it underestimates the maximum amplitude during actual SBRT. Caution must be paid to determine the margin with the 4DCT especially for tumors at the lower lobe where it is of the potentially greatest benefit.  相似文献   

4.
Stereotactic Body Radiation Therapy (SBRT), alternatively termed Stereotactic ABlative Radiotherapy (SABR) or Stereotactic RadioSurgery (SRS), delivers high dose with a sub-millimeter accuracy. It requires meticulous precautions on positioning, as sharp dose gradients near critical neighboring structures (e.g. the spinal cord for spinal tumor treatment) are an important clinical objective to avoid complications such as radiation myelopathy, compression fractures, or radiculopathy. To allow for dose escalation within the target without compromising the dose to critical structures, proper immobilization needs to be combined with (internal) motion monitoring. Metallic fiducials, as applied in prostate, liver or pancreas treatments, are not suitable in clinical practice for spine SBRT. However, the latest advances in Deep Learning (DL) allow for fast localization of the vertebrae as landmarks. Acquiring projection images during treatment delivery allows for instant 2D position verification as well as sequential (delayed) 3D position verification when incorporated in a Digital TomoSynthesis (DTS) or Cone Beam Computed Tomography (CBCT). Upgrading to an instant 3D position verification system could be envisioned with a stereoscopic kilovoltage (kV) imaging setup. This paper describes a fast DL landmark detection model for vertebra (trained in-house) and evaluates its accuracy to detect 2D motion of the vertebrae with the help of projection images acquired during treatment. The introduced motion consists of both translational and rotational variations, which are detected by the DL model with a sub-millimeter accuracy.  相似文献   

5.
The purpose of this study is to validate the capability of in-house independent point dose calculation software to be used as a second check for Helical Tomotherapy treatment plans. The software performed its calculations in homogenous conditions (using the Cheese phantom, which is a cylindrical phantom with radius 15 cm and length 18 cm) using a factor-based algorithm. Fifty patients, who were treated for pelvic (10), prostate (14), lung (10), head & neck (12) and brain (4) cancers, were used. Based on the individual patient kVCT images and the pretreatment MVCT images for each treatment fraction, the corresponding daily patient setup shifts in the IEC-X, IEC-Y, and IEC-Z directions were registered. For each patient, the registered fractional setup shifts were grouped into systematic and random shifts. The average systematic dosimetric variations showed small dose deviation for the different cancer types (1.0%–3.0%) compared to the planned dose. Of the fifty patients, only three had percent differences larger than 5%. The average random dosimetric variations showed relatively small dose deviations (0.2%–1.1%) compared to the planned dose. None of the patients had percent differences larger than 5%. By examining the individual fractions of each patient, it is observed that only in 31 out of 1358 fractions the percent differences exceeded the border of 5%. These results indicate that the overall dosimetric impact from systematic and random variations is small and that the software is a capable platform for independent point dose validation for the Helical Tomotherapy modality.  相似文献   

6.
IntroductionWe evaluated the impact of 4DCT artifacts on carbon-ion pencil beam scanning dose distributions in lung and liver treatment.Methods & materials4DCT was performed in 20 liver and lung patients using area-detector CT (original 4DCT). 4DCT acquisition by multi-detector row CT was simulated using original 4DCT by selecting other phases randomly (plus/minus 20% phases). Since tumor position can move over the respiratory range in original 4DCT, mid-exhalation was set as reference phase. Total prescribed dose of 60 Gy (RBE) was delivered to the clinical target volume (CTV). Reference dose distribution was calculated with the original CT, and actual dose distributions were calculated with treatment planning parameters optimized using the simulated CT (simulated dose). Dose distribution was calculated by substituting these parameters into the original CT.ResultsFor liver cases, CTV-D95 and CTV-Dmin values for the reference dose were 97.6 ± 0.5% and 89.8 ± 0.6% of prescribed dose, respectively. Values for the simulated dose were significantly degraded, to 88.6 ± 14.0% and 46.3 ± 26.7%, respectively. Dose assessment results for lung cases were 84.8 ± 12.8% and 58.0 ± 24.5% for the simulated dose, showing significant degradation over the reference dose of 95.1 ± 1.5% and 87.0 ± 2.2%, respectively.Conclusions4DCT image quality should be closely checked to minimize degradation of dose conformation due to 4DCT artifacts. Medical staff should pay particular attention to checking the quality of 4DCT images as a function of respiratory phase, because it is difficult to recognize 4DCT artifact on a single phase in some cases  相似文献   

7.
Respiratory movement information is useful for radiation therapy, and is generally obtained using 4D scanners (4DCT). In the interest of patient safety, reducing the use of 4DCT could be a significant step in reducing radiation exposure, the effects of which are not well documented. The authors propose a customized 4D numerical phantom representing the organ contours. Firstly, breathing movement can be simulated and customized according to the patient’s anthroporadiametric data. Using learning sets constituted by 4D scanners, artificial neural networks can be trained to interpolate the lung contours corresponding to an unknown patient, and then to simulate its respiration. Lung movement during the breathing cycle is modeled by predicting the lung contours at any respiratory phases. The interpolation is validated comparing the obtained lung contours with 4DCT via Dice coefficient. Secondly, a preliminary study of cardiac and œsophageal motion is also presented to demonstrate the flexibility of this approach. The application may simulate the position and volume of the lungs, the œsophagus and the heart at every phase of the respiratory cycle with a good accuracy: the validation of the lung modeling gives a Dice index greater than 0.93 with 4DCT over a breath cycle.  相似文献   

8.
PurposeWe have developed a new method to track tumor position using fluoroscopic images, and evaluated it using hepatocellular carcinoma case data.MethodsOur method consists of a training stage and a tracking stage. In the training stage, the model data for the positional relationship between the diaphragm and the tumor are calculated using four-dimensional computed tomography (4DCT) data. The diaphragm is detected along a straight line, which was chosen to avoid 4DCT artifact. In the tracking stage, the tumor position on the fluoroscopic images is calculated by applying the model to the diaphragm. Using data from seven liver cases, we evaluated four metrics: diaphragm edge detection error, modeling error, patient setup error, and tumor tracking error. We measured tumor tracking error for the 15 fluoroscopic sequences from the cases and recorded the computation time.ResultsThe mean positional error in diaphragm tracking was 0.57 ± 0.62 mm. The mean positional error in tumor tracking in three-dimensional (3D) space was 0.63 ± 0.30 mm by modeling error, and 0.81–2.37 mm with 1–2 mm setup error. The mean positional error in tumor tracking in the fluoroscopy sequences was 1.30 ± 0.54 mm and the mean computation time was 69.0 ± 4.6 ms and 23.2 ± 1.3 ms per frame for the training and tracking stages, respectively.ConclusionsOur markerless tracking method successfully estimated tumor positions. We believe our results will be useful in increasing treatment accuracy for liver cases.  相似文献   

9.
Body composition measurement is of cardinal significance for medical and clinical applications. Currently, the dual-energy X-ray absorptiometry (DEXA) technique is widely applied for this measurement. In this study, we present a novel measurement method using the absorption and phase information obtained simultaneously from the X-ray grating-based interferometer (XGI). Rather than requiring two projection data sets with different X-ray energy spectra, with the proposed method, both the areal densities of the bone and the surrounding soft tissue can be acquired utilizing one projection data set. By using a human body phantom constructed to validate the proposed method, experimental results have shown that the compositions can be calculated with an improved accuracy comparing to the dual energy method, especially for the soft tissue measurement. Since the proposed method can be easily implemented on current XGI setup, it will greatly extend the applications of the XGI, and meanwhile has the potential to be an alternative to DEXA for human body composition measurement.  相似文献   

10.
PurposeEdge illumination (EI) X-ray phase-contrast imaging (XPCI) has been under development at University College London in recent years, and has shown great potential for both laboratory and synchrotron applications. In this work, we propose a new acquisition and processing scheme. Contrary to existing retrieval methods for EI, which require as input two images acquired in different setup configurations, the proposed approach can retrieve an approximate map of the X-ray phase from a single image, thus significantly simplifying the acquisition procedure and reducing data collection times.MethodsThe retrieval method is analytically derived, based on the assumption of a quasi-homogeneous object, i.e. an object featuring a constant ratio between refractive index and absorption coefficient. The noise properties of the input and retrieved images are also theoretically analyzed under the developed formalism. The method is applied to experimental synchrotron images of a biological object.ResultsThe experimental results show that the method can provide high-quality images, where the “edge” signal typical of XPCI images is transformed to an “area” contrast that enables an easier interpretation of the sample geometry. Moreover, the retrieved images confirm that the method is highly stable against noise.ConclusionsWe anticipate that the developed approach will become the method of choice for a variety of applications of EI XPCI, thanks to its ability to simplify the acquisition procedure and reduce acquisitions time and dose to the sample. Future work will focus on the adaptation of the method to computed tomography and to polychromatic radiation from X-ray tubes.  相似文献   

11.
PurposeA novel variable cycle-based respiratory guidance method was proposed to synchronize the patterns between patients’ breathing and the magnetic excitation of synchrotron under the mode of full-energy depth scanning beam delivery, in order to improve the treatment precision and efficiency for carbon ion therapy.MethodsAudio-visual biofeedback system with variable cycle-based respiratory guidance method was developed. We enrolled 6 healthy volunteers and a simulation study of the fixed cycle-based and variable cycle-based respiratory guidance with three treatment fractions was performed. A total of 72 breathing curves were collected for 4D dose calculations with three 4DCT datasets of lung tumor cases. Target dose coverage (D95: the percent dose covering 95% of the target), dose homogeneity (D5-D95), and treatment time were analyzed. The Wilcoxon signed-rank test was used for statistical difference analysis, and p < 0.05 was considered significant.ResultsWith the variable cycle-based respiratory guidance method, the breath hold phase of breathing curve could be synchronized with the synchrotron flat-top phase over time. The dose homogeneity was improved by factors of 1.94–2.92 compared to the fixed cycle-based respiratory guidance maneuvers alone or in combination with gating technique. Moreover, the treatment efficiency increased by 11–23%, depending on the duty cycle settings of the gating window.ConclusionsThe proposed variable cycle-based respiratory guidance method could improve both the treatment efficiency and precision under the mode of the full-energy depth scanning beam delivery for synchrotron-based carbon ion therapy.  相似文献   

12.
To study temporal resolved computed tomography imaging (4-Dimensional Computed Tomography: 4DCT) artifacts correlations with scanning parameters and target kinetics and to assess uncertainty introduced by 4DCT in radiotherapy treatment planning.In this work we classified 4DCT artifacts as finite gantry rotation speed related (FGS) and finite sampling frequency related (FSF). We studied FGS artifacts using a respiratory phantom and FSF artifacts using a Monte Carlo simulation of acquisition timing.From our analysis FGS localization error is comparable with image resolution determined by voxel dimensions. Remaining FGS artifacts are correlated with gantry rotation time (Trot), target velocity (v) and their interaction.FSF artifacts occurrence is correlated with sampling ratio (SR), i.e. the ratio of patient respiratory period (Tresp) and sampling time (Ts).In the studied velocity range (0–2 cm/s), using a Trot of 0,5s and a SR higher than 15, FGS and FSF artifacts became comparable with other sources of uncertainty.Our considerations are valid for “ideal” breathing pattern only. When variations from periodical breathing, high target velocity (more than 2 cm/s) or high peak to peak amplitude (more than 2 cm) are present, patient specific images artifacts analysis is recommended.  相似文献   

13.
PurposeThis work aims to validate new 6D couch features and their implementation for seated radiotherapy in RayStation (RS) treatment planning system (TPS).Materials and methodsIn RS TPS, new 6D couch features are (i) chair support device, (ii) patient treatment option of “Sitting: face towards the front of the chair”, and (iii) patient support pitch and roll capabilities. The validation of pitch and roll was performed by comparing TPS generated DRRs with planar x-rays. Dosimetric tests through measurement by 2D ion chamber array were performed for beams created with varied scanning and treatment orientation and 6D couch rotations. For the implementation of 6D couch features for treatments in a seated position, the TPS and oncology information system (Mosaiq) settings are described for a commercial chair. An end-to-end test using an anthropomorphic phantom was performed to test the complete workflow from simulation to treatment delivery.ResultsThe 6D couch features were found to have a consistent implementation that met IEC 61712 standard. The DRRs were found to have an acceptable agreement with planar x-rays based on visual inspection. For dose map comparison between measured and calculated, the gamma index analysis for all the beams was >95% at a 3% dose-difference and 3 mm distance-to-agreement tolerances. For an end-to end-testing, the phantom was successfully set up at isocenter in the seated position and treatment was delivered.ConclusionsChair-based treatments in a seated position can be implemented in RayStation through the use of newly released 6D couch features.  相似文献   

14.

Background

During a proper execution of dMLC plans, there occurs an undesired but frequent effect of the dose locally accumulated by tissue being significantly different than expected. The conventional dosimetric QA procedures give only a partial picture of the quality of IMRT treatment, because their solely quantitative outcomes usually correspond more to the total area of the detector than the actually irradiated volume.

Aim

The aim of this investigation was to develop a procedure of dynamic plans verification which would be able to visualize the potential anomalies of dose distribution and specify which tissue they exactly refer to.

Materials & methods

The paper presents a method discovered and clinically examined in our department. It is based on a Gamma Evaluation concept and allows accurate localization of deviations between predicted and acquired dose distributions, which were registered by portal as well as film dosimetry. All the calculations were performed on the self-made software GammaEval, the γ-images (2-dimensional distribution of γ-values) and γ-histograms were created as quantitative outcomes of verification.

Results

Over 150 maps of dose distribution have been analyzed and the cross-examination of the gamma images with DRRs was performed.

Conclusions

It seems, that the complex monitoring of treatment would be possible owing to the images obtained as a cross-examination of γ-images and corresponding DRRs.  相似文献   

15.
IntroductionOur markerless tumor tracking algorithm requires 4DCT data to train models. 4DCT cannot be used for markerless tracking for respiratory-gated treatment due to inaccuracies and a high radiation dose. We developed a deep neural network (DNN) to generate 4DCT from 3DCT data.MethodsWe used 2420 thoracic 4DCT datasets from 436 patients to train a DNN, designed to export 9 deformation vector fields (each field representing one-ninth of the respiratory cycle) from each CT dataset based on a 3D convolutional autoencoder with shortcut connections using deformable image registration. Then 3DCT data at exhale were transformed using the predicted deformation vector fields to obtain simulated 4DCT data. We compared markerless tracking accuracy between original and simulated 4DCT datasets for 20 patients. Our tracking algorithm used a machine learning approach with patient-specific model parameters. For the training stage, a pair of digitally reconstructed radiography images was generated using 4DCT for each patient. For the prediction stage, the tracking algorithm calculated tumor position using incoming fluoroscopic image data.ResultsDiaphragmatic displacement averaged over 40 cases for the original 4DCT were slightly higher (<1.3 mm) than those for the simulated 4DCT. Tracking positional errors (95th percentile of the absolute value of displacement, “simulated 4DCT” minus “original 4DCT”) averaged over the 20 cases were 0.56 mm, 0.65 mm, and 0.96 mm in the X, Y and Z directions, respectively.ConclusionsWe developed a DNN to generate simulated 4DCT data that are useful for markerless tumor tracking when original 4DCT is not available. Using this DNN would accelerate markerless tumor tracking and increase treatment accuracy in thoracoabdominal treatment.  相似文献   

16.
The structure of thin three-dimensional crystals of the light-harvesting chlorophyll a/b protein complex, an integral membrane protein from the photosynthetic membrane of chloroplasts, has been determined at 7 A (1 A = 0.1 nm) resolution in projection. The structure analysis was carried out by image processing of low-dose electron micrographs, and electron diffraction of thin three-dimensional crystals preserved in tannin. The three-dimensional crystals appeared to be stacks of two-dimensional crystals having p321 symmetry. Results of the image analysis indicated that the crystals were disordered, due to random translational displacement of stacked layers. This was established by a translation search routine that used the low-resolution projection of a single layer as a reference. The reference map was derived from the symmetrized average of two images that showed features consistent with the projected structure of negatively stained two-dimensional crystals. The phase shift resulting from the displacement of each layer was corrected. Phase shifts were then refined by minimizing the phase residual, bringing all layers to the same phase origin. Refined phases from different images were in agreement and reliable to 7 A resolution. A projection map was generated from the averaged phases and electron diffraction amplitudes. The map showed that the complex was a trimer composed of three protein monomers related by 3-fold symmetry. The projected density within the protein monomer suggested membrane-spanning alpha-helices roughly perpendicular to the crystal plane. The density in the centre and on the periphery of the trimeric complex was lower than that of the protein, indicating that this region contained low-density matter, such as lipids and antenna chlorophylls.  相似文献   

17.
Thin, three-dimensional crystals of CaATPase have been studied at high resolution by electron crystallography. These crystals were grown by adding purified CaATPase to appropriate concentrations of lipid, detergent and calcium. A thin film of crystals was then rapidly frozen and maintained in the frozen-hydrated state during electron microscopy. The resulting electron diffraction patterns extend to 4.1 A resolution and images contain phase data to 6 A resolution. By combining Fourier amplitudes from electron diffraction patterns with phases from images, a density map has been calculated in projection. Comparison of this map from unstained crystals with a previously determined map from negatively stained crystals reveals distinct contributions from intramembranous and extramembranous protein domains. On the basis of this distinction and of the packing of molecules in the crystal, we have proposed a specific arrangement for the ten alpha-helices that have been suggested as spanning the bilayer.  相似文献   

18.
PurposeTo use Discrete Cosine Transform to include tumor motion variations on ITV definition of SBRT patients.MethodsData from 66 patients was collected. 2D planar fluoroscopy images (FI) were available for 54 patients. Daily CBCT projections (CBCTp) from 29 patients were employed to measure interfraction amplitude variability. Systematic amplitude variations were obtained from 17 patients with data from both FI and CBCTp.Tumor motion curves obtained from FI were characterized with a Cosine model (CM), based on cosine functions to the power of 2, 4 or 6, and DCT. Performance of both models was evaluated by means of R2 coefficient and by comparing their results on Internal Target Volume (ITV) margins against those calculated from original tumor motion curves.Amplitude variations from CBCTp, as well as estimations of baseline shift variations were added to the DCT model to account for their effect on ITV margins.ResultsDCT replicated tumor motion curves with a mean R2 values for all patients of 0.86, 0.91 and 0.96 for the lateral (LAT), anterior-posterior (AP) and cranio-caudal (CC) directions respectively. CM yielded worst results, with R2 values of 0.64, 0.61 and 0.74 in the three directions.Interfraction amplitude variation increased ITV margins by a 9%, while baseline shift variability implied a 40% and 80–100% increase for normalized values of baseline shift of 0.2 and 0.4 respectively.ConclusionsProbability distribution functions of tumor positions can be successfully characterized with DCT. This permits to include tumor motion variablilities obtained from patient population into patient specific ITVs.  相似文献   

19.
PurposeSimulating low-dose Computed Tomography (CT) facilitates in-silico studies into the required dose for a diagnostic task. Conventionally, low-dose CT images are created by adding noise to the projection data. However, in practice the raw data is often simply not available. This paper presents a new method for simulating patient-specific, low-dose CT images without the need of the original projection data.MethodsThe low-dose CT simulation method included the following: (1) computation of a virtual sinogram from a high dose CT image through a radon transform; (2) simulation of a ‘reduced’-dose sinogram with appropriate amounts of noise; (3) subtraction of the high-dose virtual sinogram from the reduced-dose sinogram; (4) reconstruction of a noise volume via filtered back-projection; (5) addition of the noise image to the original high-dose image. The required scanner-specific parameters, such as the apodization window, bowtie filter, the X-ray tube output parameter (reflecting the photon flux) and the detector read-out noise, were retrieved from calibration images of a water cylinder. The low-dose simulation method was evaluated by comparing the noise characteristics in simulated images with experimentally acquired data.ResultsThe models used to recover the scanner-specific parameters fitted accurately to the calibration data, and the values of the parameters were comparable to values reported in literature. Finally, the simulated low-dose images accurately reproduced the noise characteristics in experimentally acquired low-dose-volumes.ConclusionThe developed methods truthfully simulate low-dose CT imaging for a specific scanner and reconstruction using filtered backprojection. The scanner-specific parameters can be estimated from calibration data.  相似文献   

20.
AimPatient setup errors were aimed to be reduced in radiotherapy (RT) of head-and-neck (H&N) cancer. Some remedies in patient setup procedure were proposed for this purpose.BackgroundRT of H&N cancer has challenges due to patient rotation and flexible anatomy. Residual position errors occurring in treatment situation and required setup margins were estimated for relevant bony landmarks after the remedies made in setup process and compared with previous results.Materials and methodsThe formation process for thermoplastic masks was improved. Also image matching was harmonized to the vertebrae in the middle of the target and a 5 mm threshold was introduced for immediate correction of systematic errors of the landmarks. After the remedies, residual position errors of bony landmarks were retrospectively determined from 748 orthogonal X-ray images of 40 H&N cancer patients. The landmarks were the vertebrae C1–2, C5–7, the occiput bone and the mandible. The errors include contributions from patient rotation, flexible anatomy and inter-observer variation in image matching. Setup margins (3D) were calculated with the Van Herk formula.ResultsSystematic residual errors of the landmarks were reduced maximally by 49.8% (p  0.05) and the margins by 3.1 mm after the remedies. With daily image guidance the setup margins of the landmarks were within 4.4 mm, but larger margins of 6.4 mm were required for the mandible.ConclusionsRemarkable decrease in the residual errors of the bony landmarks and setup margins were achieved through the remedies made in the setup process. The importance of quality assurance of the setup process was demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号