 共查询到20条相似文献,搜索用时 93 毫秒
1.
Diagnostic real-time PCR for detection of Salmonella in food   总被引:4,自引:0,他引:4  
A robust 5' nuclease (TaqMan) real-time PCR was developed and validated in-house for the specific detection of Salmonella in food. The assay used specifically designed primers and a probe target within the ttrRSBCA locus, which is located near the Salmonella pathogenicity island 2 at centisome 30.5. It is required for tetrathionate respiration in Salmonella. The assay correctly identified all 110 Salmonella strains and 87 non-Salmonella strains tested. An internal amplification control, which is coamplified with the same primers as the Salmonella DNA, was also included in the assay. The detection probabilities were 70% when a Salmonella cell suspension containing 10(3) CFU/ml was used as a template in the PCR (5 CFU per reaction) and 100% when a suspension of 10(4) CFU/ml was used. A pre-PCR sample preparation protocol including a preenrichment step in buffered peptone water followed by DNA extraction-purification was applied when 110 various food samples (chicken rinses, minced meat, fish, and raw milk) were investigated for Salmonella. The diagnostic accuracy was shown to be 100% compared to the traditional culture method. The overall analysis time of the PCR method was approximately 24 h, in contrast to 4 to 5 days of analysis time for the traditional culture method. This methodology can contribute to meeting the increasing demand of quality assurance laboratories for standard diagnostic methods. Studies are planned to assess the interlaboratory performance of this diagnostic PCR method.  相似文献   

2.
Salmonellae have been some of the most frequently reported etiological agents in fresh-produce-associated outbreaks of human infections in recent years. PCR assays using four innovative pairs of primers derived from hilA and sirA, positive regulators of Salmonella invasive genes, were developed to identify Salmonella enterica serotype Montevideo on and in tomatoes. Based on examination of 83 Salmonella strains and 22 non-Salmonella strains, we concluded that a pair of hilA primers detects Salmonella specifically. The detection limits of the PCR assay were 101 and 100 CFU/ml after enrichment at 37°C for 6 and 9 h, respectively. When the assay was validated by detecting S. enterica serotype Montevideo in and on artificially inoculated tomatoes, 102 and 101 CFU/g were detected, respectively, after enrichment for 6 h at 37°C. Our results suggest that the hilA-based PCR assay is sensitive and specific, and can be used for rapid detection of Salmonellae in or on fresh produce.  相似文献   

3.

Background

Enteric fever remains an important cause of morbidity in many low-income countries and Salmonella Paratyphi A has emerged as the aetiological agent in an increasing proportion of cases. Lack of adequate diagnostics hinders early diagnosis and prompt treatment of both typhoid and paratyphoid but development of assays to identify paratyphoid has been particularly neglected. Here we describe the development of a rapid and sensitive blood culture PCR method for detection of Salmonella Paratyphi A from blood, potentially allowing for appropriate diagnosis and antimicrobial treatment to be initiated on the same day.

Methods

Venous blood samples from volunteers experimentally challenged orally with Salmonella Paratyphi A, who subsequently developed paratyphoid, were taken on the day of diagnosis; 10 ml for quantitative blood culture and automated blood culture, and 5 ml for blood culture PCR. In the latter assay, bacteria were grown in tryptone soy broth containing 2.4% ox bile and micrococcal nuclease for 5 hours (37°C) before bacterial DNA was isolated for PCR detection targeting the fliC-a gene of Salmonella Paratyphi A.

Results

An optimized broth containing 2.4% ox bile and micrococcal nuclease, as well as a PCR test was developed for a blood culture PCR assay of Salmonella Paratyphi A. The volunteers diagnosed with paratyphoid had a median bacterial burden of 1 (range 0.1–6.9) CFU/ml blood. All the blood culture PCR positive cases where a positive bacterial growth was shown by quantitative blood culture had a bacterial burden of ≥ 0.3 CFU/ ml blood. The blood culture PCR assay identified an equal number of positive cases as automated blood culture at higher bacterial loads (≥0.3 CFU/ml blood), but utilized only half the volume of specimens.

Conclusions

The blood culture PCR method for detection of Salmonella Paratyphi A can be completed within 9 hours and offers the potential for same-day diagnosis of enteric fever. Using 5 ml blood, it exhibited a lower limit of detection equal to 0.3 CFU/ml blood, and it performed at least as well as automated blood culture at higher bacterial loads (≥0.3 CFU/ml blood) of clinical specimens despite using half the volume of blood. The findings warrant its further study in endemic populations with a potential use as a novel diagnostic which fills the present gap of paratyphoid diagnostics.  相似文献   

4.
As part of a major international project for the validation and standardization of PCR for detection of five major food-borne pathogens, four primer sets specific for Salmonella species were evaluated in-house for their analytical accuracy (selectivity and detection limit) in identifying 43 Salmonella spp. and 47 non-Salmonella strains. The most selective primer set was found to be 139-141 (K. Rahn, S. A. De Grandis, R. C. Clarke, S. A. McEwen, J. E. Galán, C. Ginocchio, R. Curtiss III, and C. L. Gyles, Mol. Cell. Probes 6:271-279, 1992), which targets the invA gene. An extended determination of selectivity by using 364 strains showed that the inclusivity was 99.6% and the exclusivity was 100% for the invA primer set. To indicate possible PCR inhibitors derived from the sample DNA, an internal amplification control (IAC), which was coamplified with the invA target gene, was constructed. In the presence of 300 DNA copies of the IAC, the detection probability for primer set 139-141 was found to be 100% when a cell suspension containing 104 CFU/ml was used as the template in the PCR (50 CFU per reaction). The primer set was further validated in an international collaborative study that included 16 participating laboratories. Analysis with 28 coded (“blind”) DNA samples revealed an analytical accuracy of 98%. Thus, a simple PCR assay that is specific for Salmonella spp. and amplifies a chromosomal DNA fragment detected by gel electrophoresis was established through extensive validation and is proposed as an international standard. This study addresses the increasing demand of quality assurance laboratories for standard diagnostic methods and presents findings that can facilitate the international comparison and exchange of epidemiological data.  相似文献   

5.
Loop-mediated isothermal amplification (LAMP) assay was effective in detecting Salmonella enterica in naturally contaminated liquid egg samples. Salmonella was detected in 110 samples taken from four egg-breaking plants. The egg samples were pre-enriched in buffered peptone water (BPW) at 37°C for 20 h. The selective enrichment was done in Rappaport-Vassiliadis or tetrathionate broth and plated onto xylose lysine deoxycholate agar and brilliant green agar, modified. In addition, the PCR assay was used to detect Salmonella after pre-enrichment in BPW at 37°C for 20 h. The culture method and PCR assay were compared to the LAMP assay, which was also performed after pre-enrichment in BPW. PCR failed to detect Salmonella in 10% of 110 samples, whereas the culture method and LAMP assay successfully identified Salmonella in all samples. However, the LAMP assay was found to be much more rapid than the culture method and as sensitive in detecting Salmonella from liquid eggs. In all of the egg-breaking plants studied, Salmonella was isolated on most tested days. The positive samples showed that more than 75% of the Salmonella strains had identical genetic patterns when analyzed by pulsed-field gel electrophoresis. This suggests that the same Salmonella strains having survived long periods of time in the plants were contaminating the production line. The LAMP assay is rapid, specific, and sensitive for Salmonella detection in liquid eggs and is able to monitor Salmonella contamination in egg-handling plants more reliably.  相似文献   

6.
Enteroinvasive Escherichia coli (EIEC), heat-labile enterotoxin (LT) E. coli, Shigella spp., and Salmonella spp. are common enteric pathogens, which cause food-borne diseases if consumed in contaminated milk products. The rapid and reliable methods for detecting are imperative for reduction in hazard of infection. In this study, we selected primers, optimized the polymerase chain reaction (PCR) conditions, and analyzed the sensitivity and specificity of the multiplex PCR assay to screen raw milk from these enteric bacteria. Furthermore, EIEC, LT-E. coli, Shigella spp., Salmonella spp., and 11 non-targeted pathogenic strains were performed for the specificity of the multiplex PCR. Specific bands showed in EIEC, LT-E. coli, Shigella spp., and Salmonella spp. but no bands showed in other 11 pathogenic strains. The sensitivity of multiplex PCR was relatively high, was rounded to 200 CFU/ml (Shigella spp. and EIEC), 320 CFU/ml (Salmonella spp.), and 100 CFU/ml (LT-E. coli). This method for simultaneous and rapid detection of enteric pathogens (EIEC, LT-E. coli, Shigella spp., and Salmonella spp.) in raw milk showed high sensitivity and specificity, and led to faster track to report results.  相似文献   

7.
Presumptive identification of Escherichia coli O157:H7 is possible in an individual, nonmultiplexed PCR if the reaction targets the enterohemorrhagic E. coli (EHEC) eaeA gene. In this report, we describe the development and evaluation of the sensitivity and specificity of a PCR-based 5′ nuclease assay for presumptively detecting E. coli O157:H7 DNA. The specificity of the eaeA-based 5′ nuclease assay system was sufficient to correctly identify all E. coli O157:H7 strains evaluated, mirroring the previously described specificity of the PCR primers. The SZ-primed, eaeA-targeted 5′ nuclease detection assay was capable of rapid, semiautomated, presumptive detection of E. coli O157:H7 when ≥103 CFU/ml was present in modified tryptic soy broth (mTSB) or modified E. coli broth and when ≥104 CFU/ml was present in ground beef-mTSB mixtures. Incorporating an immunomagnetic separation (IMS) step, followed by a secondary enrichment culturing step and DNA recovery with a QIAamp tissue kit (Qiagen), improved the detection threshold to ≥102 CFU/ml. Surprisingly, immediately after IMS, the sensitivity of culturing on sorbitol MacConkey agar containing cefeximine and tellurite (CT-SMAC) was such that identifiable colonies were demonstrated only when ≥104 CFU/ml was present in the sample. Several factors that might be involved in creating these false-negative CT-SMAC culture results are discussed. The SZ-primed, eaeA-targeted 5′ nuclease detection system demonstrated that it can be integrated readily into standard culturing procedures and that the assay can be useful as a rapid, automatable process for the presumptive identification of E. coli O157:H7 in ground beef and potentially in other food and environmental samples.  相似文献   

8.
A rapid and sensitive 8-h PCR assay has been developed for detection of Salmonella serovars in seafood. A total of 110 fresh and raw seafood samples were analysed for the presence of Salmonella using different enrichment periods prior to PCR assay. Seafood samples included in this study were fish, shrimps, mussels, crabs, edible oysters, and clams, collected from local fish markets in Cochin (India). The assay was performed with a Salmonella-specific 284 bp invA gene amplicon. Specificity and sensitivity of the assay were ascertained with seafoods spiked with viable Salmonella cells to a level of 106 to 2 CFU per 25 g. Detection efficiency of the assay increased with increasing enrichment period for seafood, and 33.6% of seafood samples were found positive for Salmonella by 8-h PCR assay. Detection limit for the 8-h PCR assay showed visible 284 bp amplicon from seafood homogenates spiked with 2 CFU per 25 g. Seafood samples spiked with different Salmonella serovars, namely Salmonella typhi, Salmonella typhimurium, Salmonella enteritidis, Salmonella mbandka, Salmonella bareilly, and Salmonella weltevreden, were detected, confirming this technique would be ideal for detection of the Salmonella serovars prevalent in seafood. This study also covered inhibition by the seafood matrix and the detection limit for dead Salmonella cells during the PCR assay. There was no visible inhibition of this Salmonella PCR assay by seafood matrices. The detection limit for dead Salmonella cells by 8-h PCR assay was 2 × 103 CFU per 25 g seafood. The data indicated that dead cells of Salmonella in naturally contaminated seafood samples do not interfere with the assay resulting in false positives.  相似文献   

9.
A multiplex fluorogenic PCR assay for simultaneous detection of pathogenic Salmonella strains and Escherichia coli O157:H7 was developed and evaluated for use in detecting very low levels of these pathogens in meat and feces. Two sets of primers were used to amplify a junctional segment of virulence genes sipB and sipC of Salmonella and an intragenic segment of gene eae of E. coli O157:H7. Fluorogenic reporter probes were included in the PCR assay for automated and specific detection of amplified products. The assay could detect <10 CFU of Salmonella enterica serovar Typhimurium or E. coli O157:H7 per g of meat or feces artificially inoculated with these pathogens and cultured for 6 to 18 h in a single enrichment broth. Detection of amplification products could be completed in ≤4 h after enrichment.  相似文献   

10.
Polymerase chain reaction (PCR) primers for O9 antigen (rfbE) and phase 1 flagellin antigen (fliC) were designed for the rapid identification and detection of Salmonella serovar Enteritidis and Dublin. The rfbE primer pairs selectively amplified the rfbE region of group O9 Salmonella serovars. The fliC primer pairs amplified the DNAs of g,m and g,p-type flagellar antigen; Salmonella serovar Enteritidis, Dublin, and Essen. However, DNA from flagellar-negative Salmonella serovar Gallinarum-Pullorum was also amplified. The sensitivity of PCR primer pairs was 10 CFU/assay by boiled DNA preparation and 102 CFU/assay by proteinase K-treated DNA preparation.  相似文献   

11.
The application of rapid, specific, and sensitive methods for pathogen detection and quantification is very advantageous in diagnosis of human pathogens in several applications, including food analysis. The aim of this study was the evaluation of a method for the multiplexed detection and quantification of three significant foodborne pathogenic species (Escherichia coli O157, Salmonella spp., and Listeria monocytogenes). The assay combines specific DNA extraction by multiplex magnetic capture hybridization (mMCH) with multiplex real-time PCR. The amplification assay showed linearity in the range 106–10 genomic units (GU)/PCR for each co-amplified species. The sensitivity corresponded to 1 GU/PCR for E. coli O157 and L. monocytogenes, and 10 GU/PCR for Salmonella spp. The immobilization process and the hybrid capture of the MCH showed good efficiency and reproducibility for all targets, allowing the combination in equal amounts of the different nanoparticle types in mMCH. MCH and mMCH efficiencies were similar. The detection limit of the method was 10 CFU in samples with individual pathogens and 102 CFU in samples with combination of the three pathogens in unequal amounts (amount’s differences of 2 or 3 log). In conclusion, this multiplex molecular platform can be applied to determine the presence of target species in food samples after culture enrichment. In this way, this method could be a time-saving and sensitive tool to be used in routine diagnosis.  相似文献   

12.
Because biochemical testing and 16S rRNA sequence analysis have proven inadequate for the differentiation of Vibrio parahaemolyticus from closely related species, we employed the gyrase B gene (gyrB) as a molecular diagnostic probe. The gyrB genes of V. parahaemolyticus and closely related Vibrio alginolyticus were cloned and sequenced. Oligonucleotide PCR primers were designed for the amplification of a 285-bp fragment from within gyrB specific for V. parahaemolyticus. These primers recognized 117 of 117 reference and wild-type V. parahaemolyticus strains, whereas amplification did not occur when 90 strains of 37 other Vibrio species or 60 strains representing 34 different nonvibrio species were tested. In 100-μl PCR mixtures, the lower detection limits were 5 CFU for live cells and 4 pg for purified DNA. The possible application of gyrB primers for the routine identification of V. parahaemolyticus in food was examined. We developed and tested a procedure for the specific detection of the target organism in shrimp consisting of an 18-h preenrichment followed by PCR amplification of the 285-bp V. parahaemolyticus-specific fragment. This method enabled us to detect an initial inoculum of 1.5 CFU of V. parahaemolyticus cells per g of shrimp homogenate. By this approach, we were able to detect V. parahaemolyticus in all of 27 shrimp samples artificially inoculated with this bacterium. We present here a rapid, reliable, and sensitive protocol for the detection of V. parahaemolyticus in shrimp.  相似文献   

13.
We have developed a rapid procedure for the detection of virulent Yersinia enterocolitica in ground pork by combining a previously described PCR with fluorescent dye technologies. The detection method, known as the fluorogenic 5′ nuclease assay (TaqMan), produces results by measuring the fluorescence produced during PCR amplification, requiring no post-PCR processing. The specificity of the chromosomal yst gene-based assay was tested with 28 bacterial isolates that included 7 pathogenic and 7 nonpathogenic serotypes of Y. enterocolitica, other species of Yersinia (Y. aldovae, Y. pseudotuberculosis, Y. mollaretti, Y. intermedia, Y. bercovieri, Y. ruckeri, Y. frederiksenii, and Y. kristensenii), and other enteric bacteria (Escherichia, Salmonella, Citrobacter, and Flavobacterium). The assay was 100% specific in identifying the pathogenic strains of Y. enterocolitica. The sensitivity of the assay was found to be ≥102 CFU/ml in pure cultures and ≥103 CFU/g in spiked ground pork samples. Results of the assay with food enrichments prespiked with Y. enterocolitica serotypes O:3 and O:9 were comparable to standard culture results. Of the 100 field samples (ground pork) tested, 35 were positive for virulent Y. enterocolitica with both 5′ nuclease assay and conventional virulence tests. After overnight enrichment the entire assay, including DNA extraction, amplification, and detection, could be completed within 5 h.  相似文献   

14.
Despite the beneficial role of Saccharomyces cerevisiae in the food industry for food and beverage production, it is able to cause spoilage in wines. We have developed a real-time PCR method to directly detect and quantify this yeast species in wine samples to provide winemakers with a rapid and sensitive method to detect and prevent wine spoilage. Specific primers were designed for S. cerevisiae using the sequence information obtained from a cloned random amplified polymorphic DNA band that differentiated S. cerevisiae from its sibling species Saccharomyces bayanus, Saccharomyces pastorianus, and Saccharomyces paradoxus. The specificity of the primers was demonstrated for typical wine spoilage yeast species. The method was useful for estimating the level of S.cerevisiae directly in sweet wines and red wines without preenrichment when yeast is present in concentrations as low as 3.8 and 5 CFU per ml. This detection limit is in the same order as that obtained from glucose-peptone-yeast growth medium (GPY). Moreover, it was possible to quantify S. cerevisiae in artificially contaminated samples accurately. Limits for accurate quantification in wine were established, from 3.8 × 105 to 3.8 CFU/ml in sweet wine and from 5 × 106 to 50CFU/ml in red wine.  相似文献   

15.
A PCR-based method was developed for the stone fruit quarantine pathogen Xanthomonas arboricola pv. pruni (Xap), which provides rapid, sensitive and specific in planta detection and isolate identification. Primers specific for Xap were identified using random amplified polymorphic DNA (RAPD). Simplex PCR with these primers had a limit of detection per PCR reaction of approximately 10 CFU for isolate cultures and 50 CFU for plant material when used on tenfold dilutions of isolate culture or genomic DNA extracted from spiked samples, respectively. The primers were adapted as a high-throughput single-step screening based on a digoxigenin-labeled DNA probe assay with a detection limit of 4 × 102 CFU from isolate cultures. A duplex-PCR method was designed that includes the pathovar-level with species-level primers based on species-specific regions of the quinate metabolic gene qumA, increasing diagnostic confidence and offering the first molecular test for all X. arboricola pathovars.  相似文献   

16.
Aims: Salmonella spp. are an important cause of food‐borne infections throughout world, and the availability of rapid and simple detection techniques is critical for the food industry. Salmonella enterica serovars Enteritidis and Typhimurium cause the majority of human gastroenteritis infections, and there are a reported 40 000 cases of salmonellosis in the United States each year. Methods and Results: A novel rapid and simple isothermal target and probe amplification (iTPA) assay that rapidly amplifies target DNA (Salmonella invA gene) using a FRET‐based signal probe in an isothermal environment was developed for detection Salmonella spp. in pre‐enriched food samples. The assay was able to specifically detect all of 10 Salmonella spp. strains without detecting 40 non‐Salmonella strains. The detection limit was 4 × 101 CFU per assay. The iTPA assay detected at an initial inoculum level of <10 CFU in the pre‐enriched food samples (egg yolk, chicken breast and peanut butter). Conclusions: This detection system requires only a water bath and a fluorometer and has great potential for use as a hand‐held device or point‐of‐care‐testing diagnostics. The iTPA assay is sensitive and specific and has potential for rapid screening of Salmonella spp. by food industry.  相似文献   

17.
An automated fluorescence-based PCR system (a model AG-9600 AmpliSensor analyzer) was investigated to determine whether it could detect Shiga toxin-producing Escherichia coli (STEC). The AmpliSensor PCR assay involves amplification-mediated disruption of a fluorogenic DNA signal duplex (AmpliSensor) that is homologous to conserved target sequences in a 323-bp amplified fragment of Shiga toxin genes stx1, stx2, and stxe. Using the Amplisensor assay, we detected 113 strains of STEC belonging to 50 different serotypes, while 18 strains of non-Shiga-toxin-producing E. coli and 68 strains of other bacteria were not detected. The detection limits of the assay were less than 1 to 5 CFU per PCR mixture when pure cultures of five reference strains were used and 3 CFU per 25 g of food when spiked ground beef samples that were preenriched overnight were used. The performance of the assay was also evaluated by using 53 naturally contaminated meat samples and 48 raw milk samples. Thirty-two STEC-positive samples that were confirmed to be positive by the culture assay were found to be positive when the AmpliSensor assay was used. Nine samples that were found to be positive when the PCR assay was used were culture negative. The system described here is an automated PCR-based system that can be used for detection of all serotypes of STEC in food or clinical samples.  相似文献   

18.
Cronobacter spp. is an emerging pathogen that causes meningitis, sepsis, bacteremia, and necrotizing enterocolitis in neonates and children. The present study developed an assay integrating real-time PCR and high resolution melting (HRM) analysis targeting the OmpA gene for the specific detection and rapid identification of Cronobacter spp. (formerly Enterobacter sakazakii) in powdered infant formula. Eleven Cronobacter field isolates and 25 reference strains were examined using one pair of primers, having the accuracy of 100% in reference to conventional methods. The assay was proved to be highly sensitive with a detection limit of 102 CFU/ml without pre-enrichment, and highly concordant (100%) when compared with ISO-IDF 22964 in 89 actual samples. The method performed for Cronobacter spp. detection was less than 24 h, drastically shortened, compared to several days using standard culturing method, it is probe-free and reduces a risk of PCR carryover. Moreover, all Cronobacter strains examined in this study were genotyped into two species according to their HRM profiles. The established method should provide a molecular tool for direct detection and simultaneous genotyping of Cronobacter spp. in powdered infant formula.  相似文献   

19.
A new two-step filtration protocol followed by a real-time PCR assay based on SYBR green I detection was developed to directly quantitate salmonellae in two types of biological samples: i.e., chicken rinse and spent irrigation water. Four prefiltration filters, one type of final filter, and six protocols for recovery of salmonellae from the final filter were evaluated to identify an effective filtration protocol. This method was then combined with a real-time PCR assay based on detection of the invA gene. The best results were obtained by subsequent filtration of 100 ml of chicken rinse or 100 ml of spent irrigation water through filters with pore diameters of >40 μm to remove large particles and of 0.22 μm to recover the Salmonella cells. After this, the Salmonella cells were removed from the filter by vortexing in 1 ml of physiological saline, and this sample was then subjected to real-time quantitative PCR. The whole procedure could be completed within 3 h from sampling to quantitation, and cell numbers as low as 7.5 × 102 CFU per 100-ml sample could be quantified. Below this limit, qualitative detection of concentrations as low as 2.2 CFU/100 ml sample was possible on occasion. This study has contributed to the development of a simple, rapid, and reliable method for quantitation of salmonellae in food without the need for sample enrichment or DNA extraction.  相似文献   

20.
A PCR procedure has been developed for routine analysis of viable Salmonella spp. in feed samples. The objective was to develop a simple PCR-compatible enrichment procedure to enable DNA amplification without any sample pretreatment such as DNA extraction or cell lysis. PCR inhibition by 14 different feed samples and natural background flora was circumvented by the use of the DNA polymerase Tth. This DNA polymerase was found to exhibit a high level of resistance to PCR inhibitors present in these feed samples compared to DyNAzyme II, FastStart Taq, Platinum Taq, Pwo, rTth, Taq, and Tfl. The specificity of the Tth assay was confirmed by testing 101 Salmonella and 43 non-Salmonella strains isolated from feed and food samples. A sample preparation method based on culture enrichment in buffered peptone water and DNA amplification with Tth DNA polymerase was developed. The probability of detecting small numbers of salmonellae in feed, in the presence of natural background flora, was accurately determined and found to follow a logistic regression model. From this model, the probability of detecting 1 CFU per 25 g of feed in artificially contaminated soy samples was calculated and found to be 0.81. The PCR protocol was evaluated on 155 naturally contaminated feed samples and compared to an established culture-based method, NMKL-71. Eight percent of the samples were positive by PCR, compared with 3% with the conventional method. The reasons for the differences in sensitivity are discussed. Use of this method in the routine analysis of animal feed samples would improve safety in the food chain.  相似文献   