Electrochemical monitoring of malondialdehyde biomarker in biological samples via electropolymerized amino acid/chitosan nanocomposite |
| |
Authors: | Mohammad Hasanzadeh Fozieh Mokhtari Vahid Jouyban‐Gharamaleki Ahad Mokhtarzadeh Nasrin Shadjou |
| |
Affiliation: | 1. Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran;2. Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran;3. Department of Mechatronic Engineering, International Campus, University of Tabriz, Tabriz, Iran;4. Research Center of Immunology, Tabriz University of Medical Sciences, Tabriz, Iran;5. Department of Nanochemistry, Nano Technology Research Center, Urmia University, Urmia, Iran |
| |
Abstract: | This study reports on the electropolymerization of a low toxic and biocompatible nanopolymer with entitle poly arginine‐graphene quantum dots‐chitosan (PARG‐GQDs‐CS) as a novel strategy for surface modification of glassy carbon surface and preparation of a new interface for measurement of malondialdehyde (MDA) in exhaled breath condensate. Electrochemical deposition, as a well‐controlled synthesis procedure, has been used for subsequently layer‐by‐layer preparation of GQDs‐CS nanostructures on a PARG prepolymerized on the surface of glassy carbon electrode using cyclic voltammetry techniques in the regime of ?1.5 to 2 V. The modified electrode appeared as an effective electroactivity for detection of MDA by using cyclic voltammetry, linear sweep voltammetry, and differential pulse voltammetry. The prepared modified electrode demonstrated a noticeably good activity for electrooxidation of MDA than PARG. Enhancement of peak currents is ascribed to the fast heterogeneous electron transfer kinetics that arise from the synergistic coupling between the excellent properties of PARG and semiconducting polymer, GQDs as high density of edge plane sites and subtle electronic characteristics and unique properties of CS such as excellent film‐forming ability, high permeability, good adhesion, nontoxicity, cheapness, and a susceptibility to chemical modification. The prepared sensor showed 1 oxidation processes for MDA at potentials about 1 V with a low limit of quantification 5.94 nM. Finally, application of new sensor for determination of MDA in exhaled breath condensate was suited. In general, the simultaneous attachment of GQDs and CS to structure of poly amino acids provides new opportunities within the personal healthcare. |
| |
Keywords: | biomarker biomedical analysis interface science nanobiopolymer semiconductor |
|
|