首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Molecular Flow Quantified beyond the Diffraction Limit by Spatiotemporal Image Correlation of Structured Illumination Microscopy Data
Authors:George?W Ashdown  Andrew Cope  Paul?W Wiseman  Dylan?M Owen
Institution:1.Department of Physics and Randall Division of Cell and Molecular Biophysics, King’s College London, London, United Kingdom;2.Academic Department of Rheumatology, Centre for Molecular and Cellular Biology of Inflammation, Division of Immunology, Infection and Inflammatory Disease, King’s College London, London, United Kingdom;3.Departments of Chemistry and Physics, McGill University, Montreal, Quebec, Canada
Abstract:We combine total internal reflection fluorescence structured illumination microscopy with spatiotemporal image correlation spectroscopy to quantify the flow velocities and directionality of filamentous-actin at the T cell immunological synapse. These techniques demonstrate it is possible to image retrograde flow of filamentous-actin at superresolution and provide flow quantification in the form of velocity histograms and flow vector maps. The flow was found to be retrograde and radially directed throughout the periphery of T-cells during synapse formation.Many biological processes are now being visualized with the use of superresolution fluorescence microscopy techniques. However, localization-based techniques primarily rely on fixed or slow moving samples to permit the collection of structural information. The 10-fold gains in resolution afforded by these superresolution techniques are usually possible through sacrificing the factors that originally made microscopy such a powerful tool: the ability to image live cells. In the case of stimulated emission depletion imaging, the scanning approach associated with this technique may fail to detect faster molecular events when imaging whole cellular regions.Structured illumination microscopy (SIM) is an alternative to these methods (1). It increases the resolution of conventional fluorescence microscopy twofold; it has the advantage of using a wide-field system, providing fast acquisition speeds of whole cells with relatively low laser powers; and it is compatible with standard fluorophores. By using a physical grating to produce interference patterns from a laser, periodic illumination is created. This patterned illumination causes information from higher spatial frequencies to be downmodulated (i.e., shifted) into the optical transfer function (support region) of the lens, resulting in higher-resolution spatial information being captured than is ordinarily obtainable.To quantify the directional motion of intracellular molecules, spatiotemporal image correlation spectroscopy (STICS (2)) was applied. Using spatial image correlation in time, STICS measures the similarity of pixels with those surrounding in lagging frames via a correlation function. The correlation function provides information on both flow velocities and directionality, while discounting static structures through the immobile object filter, achieved by subtracting a moving average of pixel intensities.The formation of an immunological synapse between T cells and antigen-presenting cells is a process requiring many dynamic (3) and subdiffraction-limited clustering events (4–6) to take place. The polymerization of actin is important for the spreading of cells over their target antigen-presenting cells (7), as well as cell mobility and migration (8). Retrograde flow of densely meshed cortical actin is observed at the basal membrane of synapse-forming T cells, where it may have a role in the corralling and clustering of signaling molecules at the plasma membrane (9), as well as at the leading edge of migrating cells (10). Filamentous actin is an extremely dynamic (7), densely packed, and thin (7-nm) structure (11,12).Here, we perform STICS on SIM data acquired on a total internal reflection fluorescence (TIRF) microscope system, which generated an evanescent field of 75-nm depth for excitation. To our knowledge, this is the first demonstration of an image correlation approach to quantify molecular dynamics on subresolution length scales using wide-field microscopy. To demonstrate the technique, we analyze two-dimensional actin flows in CD4+ T cells during immunological synapse formation, performed after cross-linking of antigen T cell receptors on a coverslip coated with specific antibodies.Fig. 1 a shows a schematic of the TIRF SIM setup. Excitation light (488 nm) passes through a polarizing module and then a phase-grating block, producing diffracted beams. These are then passed through a diffraction filter module to isolate the −1 and +1 order laser beams. These first-order laser beams are angled through the objective to produce total internal reflection conditions at the glass-water interface. The two evanescent waves interfere at the sample, producing structured illumination. The setup then produces lateral and rotational shifts through three orientations, producing nine raw images containing higher spatial frequencies than can normally be acquired by an objective using standard light microscopy. Fig. 1 b demonstrates the increased resolution obtained from TIRF SIM. Shown are the collected Fourier frequencies compared to those of a conventional microscope (dotted red line). Resolution was also measured using sparse 100-nm diameter fluorescent beads. Fig. 1 c shows a magnified image of these beads from which a line profile was obtained (yellow arrow). The full width at half-maximum of this profile (Fig. 1 d) gives a lateral resolution for the system of 120 nm.Open in a separate windowFigure 1(a) Schematic of the TIRF SIM setup. (b) Demonstration of the doubling of spatial resolution of collected frequencies through a Fourier transform (superimposed red circle demonstrating regular spatial frequency limits). (c) SIM reconstructed image of 100-nm bead (scale bar 0.5 μm). (d) (Plotted line) Bead showing full width at half-maximum of 120 nm.We then applied STICS analysis to quantify actin flow in T cell synapses acquired using TIRF SIM (Fig. 2). Fig. 2 a shows a schematic of the STICS analysis. From the raw data, immobile objects are first filtered by subtracting a moving average of the pixel values. Vector maps were obtained from correlation analysis of the time-series as previously published in Hebert et al. (2) and Brown et al. (13). Fig. 2 b shows a reconstructed TIRF SIM image of a mature T cell immunological synapse, representative of a time-point derived from the time series acquired at 1.28 fps (see Movie S1 in the Supporting Material). From this reconstructed image, two representative regions have been selected. In these regions, pseudo-colored actin flow vectors are overlaid onto the fluorescence intensity image. These range in magnitude from 0.01 μm/min (blue) to 5.61 μm/min (red). It can be observed that all flow vectors are directed radially toward the synapse center. A histogram of this flow is shown in Fig. 2 c. The histogram shows a peak retrograde flow velocity of 1.91 ± 1.27 μm/min. These data are representative of n = 7 T-cell synapses imaged by TIRF SIM.Open in a separate windowFigure 2(a) STICS analysis, performed by isolating mobile from immobile structures through a moving average filter (i) and binning a subset of pixels into blocks of superpixels (ii); the STICS software correlates spatial fluorescence fluctuations through time (iii). The code then outputs vector maps showing directionality and flow velocities. (b) TIRF SIM image of actin flow in a T cell 5 min after contact with a stimulatory coverslip. (Zoomed regions) Retrograde actin flow at the synapse periphery. (c) Histograms showing flow speed statistics of vectors from T-cell synapses (n = 7).
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号