Purification of coagulation factor VIII using chromatographic methods. Direct chromatography of plasma in anion exchange resins
Authors:Elisabeth Cheng  Daniela Jinzenji  Ana Paula Almeida Aranha Lorthiois  Roberta Rodrigues de Carvalho  Anita Mitiko Tanaka-Azevedo  Isaías Raw  Elizabeth Angélica Leme Martins
Institution:1.Centro de Biotecnologia,Instituto Butantan,S?o Paulo,Brazil;2.Programa de Pós-gradua??o Interunidades em Biotecnologia,Universidade de S?o Paulo,S?o Paulo,Brazil
Abstract:Coagulation factor VIII (FVIII) concentrates are used in the treatment of patients with Hemophilia A. Human FVIII was purified directly from plasma using anion exchange chromatography followed by gel filtration. Three Q-Sepharose resins were tested, resulting in 40% recovery of FVIII activity using Q-Sepharose XL resin, about 80% using Q-Sepharose Fast Flow and 70% using the Q-Sepharose Big Beads. The vitamin K-dependent coagulation factors co-eluted with FVIII from the anion exchange columns. In the second step of purification, when Sepharose 6FF was used, 70% of FVIII activity was recovered free from vitamin K-dependent factors.