首页 | 本学科首页   官方微博 | 高级检索  
   检索      

小麦印度腥黑穗病菌和黑麦草腥黑粉菌检测标准分子构建
引用本文:李小焦,王中康,章桂明,陈枝楠,殷幼平,程颖慧,王颖,向才玉,缪建锟.小麦印度腥黑穗病菌和黑麦草腥黑粉菌检测标准分子构建[J].微生物学通报,2010,37(10):1541-1547.
作者姓名:李小焦  王中康  章桂明  陈枝楠  殷幼平  程颖慧  王颖  向才玉  缪建锟
作者单位:1. 重庆大学生物工程学院,重庆市功能基因及调控技术重点实验室,重庆400030
2. 深圳出入境检验检疫局动植物检验检疫技术中心,广东深圳,518045;深圳市外来有害生物检测技术研发重点实验室,广东深圳,518045
3. 中国农业大学北京,100094
基金项目:国家863计划项目(No. 2006AA10Z434); 重大科技支撑项目(No. 2006BAD08A13-02)
摘    要:以小麦印度腥黑穗病菌和黑麦草腥黑粉菌为研究对象,采用分子克隆技术,分别构建了该两种真菌分子检测的标准分子。前者包括线粒体2297 bp的DNA序列以及rDNA710 bp的ITS序列,后者包括线粒体2.3kb的DNA序列以及rDNA710 bp的ITS序列。分别对该两个标准分子进行了性能评估试验,测试结果显示所构建的标准分子具有良好的特异性、均匀性和稳定性,能够满足小麦印度腥黑穗病菌和黑麦草腥黑粉菌分子检测需求。

关 键 词:克隆    分子检测    标准分子

Construction of Two Standard Molecules for Detection of Tilletia indica Mitra and Tilletia walkeri Castl.
LI Xiao-Jiao,WANG Zhong-Kang,ZHANG Gui-Ming,CHEN Zhi-Nan,YIN You-Ping,CHENG Ying-Hui,WANG Ying,XIANG Cai-Yu and MIU Jian-Kun.Construction of Two Standard Molecules for Detection of Tilletia indica Mitra and Tilletia walkeri Castl.[J].Microbiology,2010,37(10):1541-1547.
Authors:LI Xiao-Jiao  WANG Zhong-Kang  ZHANG Gui-Ming  CHEN Zhi-Nan  YIN You-Ping  CHENG Ying-Hui  WANG Ying  XIANG Cai-Yu and MIU Jian-Kun
Institution:1. Key Laboratory of Genetic Function and Regulation, College of Bioengineering, Chongqing University, Chongqing 400030, China;1. Key Laboratory of Genetic Function and Regulation, College of Bioengineering, Chongqing University, Chongqing 400030, China;2. Technical center of APIQ, Shenzhen Entr-Exit Inspection and Quarantine Bureau, Shenzhen 518000, China; 3. Shenzhen Key Laboratory for Research & Development on Detection Technology of Exotic Pests, Shenzhen 518000, China;2. Technical center of APIQ, Shenzhen Entr-Exit Inspection and Quarantine Bureau, Shenzhen 518000, China; 3. Shenzhen Key Laboratory for Research & Development on Detection Technology of Exotic Pests, Shenzhen 518000, China;1. Key Laboratory of Genetic Function and Regulation, College of Bioengineering, Chongqing University, Chongqing 400030, China;2. Technical center of APIQ, Shenzhen Entr-Exit Inspection and Quarantine Bureau, Shenzhen 518000, China; 3. Shenzhen Key Laboratory for Research & Development on Detection Technology of Exotic Pests, Shenzhen 518000, China;2. Technical center of APIQ, Shenzhen Entr-Exit Inspection and Quarantine Bureau, Shenzhen 518000, China; 3. Shenzhen Key Laboratory for Research & Development on Detection Technology of Exotic Pests, Shenzhen 518000, China;2. Technical center of APIQ, Shenzhen Entr-Exit Inspection and Quarantine Bureau, Shenzhen 518000, China; 3. Shenzhen Key Laboratory for Research & Development on Detection Technology of Exotic Pests, Shenzhen 518000, China;4. China Agricultural University, Beijing 100094, China
Abstract:Two standard molecules were constructed by molecular clone technology of Tilletia indica Mitra and Tilletia walkeri Castl.. The standard molecule for Tilletia indica Mitra contained two DNA fragments, one about 2297 bp DNA sequence from mitochondrial DNA, the other ITS sequence 710 bp. The standard molecule for Tilletia walkeri Castl. contained two DNA fragments, one about 2.3 kb DNA sequence from mitochondrial DNA, the other ITS sequence 710 bp. In this research, the two standard molecules were detected, the results show good specificity, homogeneity and stability which can satisfy the need of molecular detection of Tilletia indica Mitra and Tilletia walkeri Castl..
Keywords:Clone  Molecular detection  Standard molecule
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《微生物学通报》浏览原始摘要信息
点击此处可从《微生物学通报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号