首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Measurement of mass flow of water in the stems of herbaceous plants
Authors:J M BAKER  C H M VAN  BAVEL
Institution:Department of Soil and Crop Sciences, Texas Agricultural Experiment Station, Texas A &M University, College Station, TX 77843, U.S.A.
Abstract:Abstract. Heat balance methods of stem flow measurement offer the opportunity to measure directly the mass flow rate of water in plants. We have tested one such approach; the constant power heat balance method of Sakuratani (1981). The results supported his statement of an approximate accuracy of 10% when measuring the transpiration rate of herbaceous plants. The response to sudden changes in stem flow rate is not instantaneous, but investigation of the time constant shows that it decreases as stem flow increases, to the extent that, at flow rates typical of daytime conditions the system is capable of accurately tracking changes in stem flow within 5 min or less.
We describe a new gauge design that is relatively rugged, simple to use with an appropriate digital datalogger and suitable for field use over prolonged periods of time. It does not injure or penetrate the stem, is amenable to continuous and direct recording of the mass flow rate of water in the stem and requires no calibration. A further refinement, which should improve both the accuracy and the dynamic response of the system, is proposed.
Keywords:sap flow  stem flow  transpiration measurement  heat balance