首页 | 本学科首页   官方微博 | 高级检索  
   检索      

基于MIMIC数据库的多参数数据D/A回放系统
引用本文:张春游赵捷,李大鹏陈甜甜尹文枫安佰京张军建.基于MIMIC数据库的多参数数据D/A回放系统[J].现代生物医学进展,2014,14(10):1961-1964.
作者姓名:张春游赵捷  李大鹏陈甜甜尹文枫安佰京张军建
作者单位:山东师范大学物理与电子科学学院,山东济南250014
基金项目:山东省自然科学基金(ZR2010HM020);济南市自主创新项目(201102005)
摘    要:文中分析了MIMIC多参数智能监护数据库存储文件的识读方法,该数据库公开发表于PhysioNET,还研究及基于STM32和DAC8568的多参数数据D/A回放系统,包括系统硬件工作原理和系统软件工作原理。MIMIC多参数智能监护数据库的数据文件对于变异性较大的生理参数采用连续采样的方式,而对于相对稳定的生理参数采用周期采样的方式,因此,多参数数据各信号的抽样频率不同。系统首先通过VC++编程读取一个多抽样频率数据并在PC机上显示其波形,然后经过D/A硬件设备进行D/A转换后使用示波器输出其波形,实现输出的波形与原始的波形能同时回放。系统可作为模拟信号源,为远程多参数生理监护仪的研制奠定了基础。

关 键 词:MIMIC多参数数据库  多抽样频率数据  D  A转换  STM32  DAC8568

Multi-Parameter Data D/A Redisplay SystemBased on MIMIC Database
ZHANG Chun-you,ZHAO Jie,LI Da-peng,CHEN Tian-tian,YIN Wen-feng,AN Bai-jing,ZHANG Jun-jian.Multi-Parameter Data D/A Redisplay SystemBased on MIMIC Database[J].Progress in Modern Biomedicine,2014,14(10):1961-1964.
Authors:ZHANG Chun-you  ZHAO Jie  LI Da-peng  CHEN Tian-tian  YIN Wen-feng  AN Bai-jing  ZHANG Jun-jian
Institution:(College of Physics and Electronics Shandong Normal University, Jinan, Shandong, 250014, China)
Abstract:The paper analyzes the MIMIC Multi-Parameter intelligent monitoring database storage file's reading method, the database is published in PhysioNET. The paper also describes a multi-parameter data D/A redisplay system based on STM32 and DAC8568, including the working principle of the system hardware and the working principle of the system software. The MIMIC Multi-Parameter intelligent monitoring database's data file for the large variability of physiological parameters use continuous sampling, and the relatively stable physiological parameters use periodic sampling. Therefore, Multi-parameter data for each of the signal sampling frequency is different. Firstly, the system through VC++ programming to read more than one sampling frequency data, and display its waveform in the personal computer. Secondly, after the D/A conversion of the D/A hardware equipment, using oscilloscope output its waveform. The output waveform with the original waveform can be playback simultaneously. The system can be used as an analog signal source, and laid the foundation for the development of remote multi-parameter physiological monitor.
Keywords:MIMIC Multi-Parameter Database  More than one sampling frequency data  D/A convertion  STM32  DAC8568
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《现代生物医学进展》浏览原始摘要信息
点击此处可从《现代生物医学进展》下载免费的PDF全文