首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Evaluation of radiomic texture feature error due to MRI acquisition and reconstruction: A simulation study utilizing ground truth
Institution:1. Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois;2. Department of Radiological Sciences, University of California Irvine, Irvine, California;3. Department of Orthopedics, Affiliated Hospital of Qingdao University, Qingdao, Shandong, China;4. Department of Radiology, Peking Union Medical College Hospital, Beijing, China;5. Department of General Surgery, Nanfang Hospital, Southern Medical University, Guangdong Provincial Engineering Technology Research Center of Minimally Invasive Surgery, Guangzhou, China;6. Department of Radiology, Third Affiliated Hospital of Suzhou University, Changzhou, Jiangsu, China;7. Department of Radiology, First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China;8. Robert H. Lurie Comprehensive Cancer Center of Northwestern University, Chicago, Illinois;9. Chao Family Comprehensive Cancer Center, University of California Irvine, Irvine, California
Abstract:The purpose of this study was to examine the dependence of image texture features on MR acquisition parameters and reconstruction using a digital MR imaging phantom. MR signal was simulated in a parallel imaging radiofrequency coil setting as well as a single element volume coil setting, with varying levels of acquisition noise, three acceleration factors, and four image reconstruction algorithms. Twenty-six texture features were measured on the simulated images, ground truth images, and clinical brain images. Subtle algorithm-dependent errors were observed on reconstructed phantom images, even in the absence of added noise. Sources of image error include Gibbs ringing at image edge gradients (tissue interfaces) and well-known artifacts due to high acceleration; two of the iterative reconstruction algorithms studied were able to mitigate these image errors. The difference of the texture features from ground truth, and their variance over reconstruction algorithm and parallel imaging acceleration factor, were compared to the clinical “effect size”, i.e., the feature difference between high- and low-grade tumors on T1- and T2-weighted brain MR images of twenty glioma patients. The measured feature error (difference from ground truth) was small for some features, but substantial for others. The feature variance due to reconstruction algorithm and acceleration factor were generally smaller than the clinical effect size. Certain texture features may be preserved by MR imaging, but adequate precautions need to be taken regarding their validity and reliability. We present a general simulation framework for assessing the robustness and accuracy of radiomic textural features under various MR acquisition/reconstruction scenarios.
Keywords:Radiomics  Texture  MRI  Repeatability
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号