首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Comparative evaluation of whole blood D-dimer test to plasma D-dimer test for diagnosis of disseminated intravascular coagulation
Authors:Gupta P K  Gupta M  Chatterjee T  Saxena R
Institution:Department of Haematology, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India.
Abstract:Three rapid D-dimer test methods were compared for the diagnosis of acute disseminated intravascular coagulation (DIC). These were (a) SimpliRED, an autologous red cell agglutination assay. (b) DIMERTEST latex agglutination assay, containing monoclonal antibody DD-3B6/22(6), and (c) D-DI latex agglutination assay containing mouse anti-human D-dimer monoclonal antibodies. The D-DI latex method having higher sensitivity (100%) and specificity (81%) in clinically acute DIC was postulated as the gold standard and compared with the other two methods. The results suggest that D-DI latex agglutination assay containing mouse anti-human D-Dimer monoclonal antibodies are the better assay methods amongst all the three kits analyzed. It is advisable to look for the nature of the antibody used to coat the latex particles in plasma based kits. In emergency setting RBC kits may be of some use as rapid diagnosis is advantageous.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏