首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Emission spectroscopy diagnostics of rare gases in the PNX-U facility
Authors:S I Vetrov  A V Spitsyn  D A Shuvaev  S V Yanchenkov
Institution:(1) Nuclear Fusion Institute, Russian Research Centre Kurchatov Institute, pl. Akademika Kurchatova 1, Moscow, 123182, Russia
Abstract:Results are presented from measurements of the electron temperature and neutral atom density in a low-temperature microwave plasma by the method of emission spectroscopy. The measurements were conducted in the PNX-U facility—a magnetic confinement system with a “magnetic wall.” Multichord measurements of plasma radiation at a wavelength of 750.37 nm were performed with the help of an absolutely calibrated monochromator. The neutral atom density was calculated using the collisional-radiative model. The degree of plasma ionization near the axis of the facility was found to be close to unity. The electron temperature of the argon plasma was measured from the relative intensities of the spectral lines of neutral helium injected in small amounts into the plasma (the so-called helium thermometer method). At a low microwave heating power, the results of these measurements agree well with the results of probe measurements.
Keywords:
本文献已被 SpringerLink 等数据库收录!