首页 | 本学科首页   官方微博 | 高级检索  
   检索      

实时剪切波弹性定量分析不同睾酮水平大鼠阴茎组织硬度
引用本文:乔晓慧,邢晋放,张佳杰,高峰,杜联芳.实时剪切波弹性定量分析不同睾酮水平大鼠阴茎组织硬度[J].现代生物医学进展,2016,16(24):4640-4642.
作者姓名:乔晓慧  邢晋放  张佳杰  高峰  杜联芳
作者单位:南京医科大学附属上海一院临床医学院超声医学科;上海交通大学附属第一人民医院超声医学科
基金项目:上海申康医院发展中心临床科技创新项目(SHDC22015011);上海交通大学医学院科技基金项目(14XJ10075); 上海交通大学附属第一人民医院院级科研项目(0601N16004)
摘    要:目的:利用实时剪切波弹性成像(shear wave elastography,SWE)定量分析不同睾酮水平阴茎组织硬度之间的差异。方法:睾酮水平不同SD大鼠两组,低睾酮水平组(1月龄,睾酮水平1.00~1.50 ng/m L,n=10)和高睾酮水平组(13月龄,睾酮水平2.00~2.50ng/m L,n=10)。采用放射免疫法测定各组大鼠血清睾酮水平。选用法国Super Sonic Imagine公司生产的Aixplorer超声诊断仪,启动SWE模式对阴茎进行SWE成像并测量其剪切波硬度(shear wave stiffness,SWS)。分析比较两组大鼠血清睾酮水平之间的差异及SWS之间的差异。结果:所有大鼠血清睾酮水平及阴茎组织SWS的测量均成功完成。低睾酮水平组大鼠血清睾酮水平为(1.30±0.16)ng/m L,高睾酮水平组为(2.29±0.14)ng/m L,两组大鼠血清睾酮水平存在显著差异(P0.01);低睾酮水平组大鼠阴茎组织SWS为(9.86±0.72)k Pa,高睾酮水平组为(7.80±1.43)k Pa,两组大鼠阴茎组织SWS存在显著差异(P0.01)。结论:SWE可以检测出睾酮水平不同导致的阴茎组织硬度的差异,提示SWE可作为一项评价阴茎组织硬度的无创新技术。

关 键 词:实时剪切波弹性成像  阴茎  硬度  睾酮

Quantitative Analysis of Penis Stiffness in Rat with Different Levels of Testosterone using Shear Wave Elastography
Abstract:Objective:To quantitatively analyze the differences of penis stiffness with different levels of testosterone using shear wave elastography (SWE).Methods:Two groups of SD rats with different levels of testosterone: the low testosterone group (1 month, testosterone 1.00~1.50 ng/mL, n=10) and the high testosterone group (13 month, testosterone 2.00~2.50 ng/mL, n=10). The radioimmunoassay was used to measure the level of testosterone and the ultrasound device Aixplorer (SuperSonic Imagine, Aix-en-Provence, France) was used for the SWE imaging and SWS measurement of penis. The differences of the level of testosterone between the two groups and SWS between the two groups were analyzed.Results:The level of testosterone and SWS of penis were all successfully measured. The level of testosterone of the two groups was respectively (1.30± 0.16) ng/mL and (2.29± 0.14) ng/mL, there were significant differences of the level of testosterone between the two groups (P<0.01). The penis SWS of the two groups was respectively (9.86± 0.72) kPa and (7.80± 1.43) kPa, there were significant differences of penis SWS between the two groups (P<0.01).Conclusion:The differences of penis stiffness with different levels of testosterone can be detected using SWE. Therefore, SWE maybe serve as a potential noninvasive method of evaluating the penis stiffness.
Keywords:Shear wave elastography  Penis  Stiffness  Testosterone
本文献已被 CNKI 等数据库收录!
点击此处可从《现代生物医学进展》浏览原始摘要信息
点击此处可从《现代生物医学进展》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号