首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Higher diagnostic accuracy with the ThinPrep method in a simulated intraoperative environment
Authors:C Ho  M Khalil  M A Duggan
Institution:Department of Pathology and Laboratory Medicine, University of Calgary, Calgary, AB, Canada
Abstract:Objective:  To compare the accuracy of intraoperative fine needle aspiration cytology samples prepared by the ThinPrep method to conventional cytological methods. Specimen adequacy and turn around time (TAT) were also assessed.
Methods:  Fifty consecutive fresh tumours submitted for histological analysis were aspirated and each prepared as follows: (i) direct smear with H&E stain, (ii) direct smear with Pap stain, (iii) ThinPrep slide with H&E stain, and (iv) ThinPrep slide with Pap stain. The slides were randomly distributed to three cytopathologists for interpretation. The quality of the preparation, the diagnosis and the time needed for interpretation were recorded.
Results:  Accuracy was measured as the percentage of absolute agreement between the cytological and the histopathological diagnoses of the lesions. Histologically, there were 43 malignant and six benign lesions and one atypical lipoma. The TAT began when the slides/cytolyte specimens arrived at the lab and ended with the pathologist's diagnosis.
Conclusions:  In terms of accuracy and specimen adequacy, ThinPrep slides with Pap stain is the best procedure. This advantage however is offset by the longer testing time.
Keywords:intraoperative cytology  ThinPrep  conventional smears  cyto-histological correlation  fine needle aspiration cytology  cytological techniques  cytodiagnosis
设为首页 | 免责声明 | 关于勤云 | 加入收藏