首页 | 本学科首页   官方微博 | 高级检索  
   检索      


The construction of the scoliosis 3D finite element model and the biomechanical analysis of PVCR orthopaedy
Institution:Department of Orthopedics, The Affiliated Hospital of Putian University, Putian 351100, China
Abstract:ObjectiveThe objective is to investigate the biomechanical conditions of the Posterior Vertebral Column Resection (PVCR) of the constructed scoliosis 3D finite element model.MethodsA patient with scoliosis was selected; before the PVCR orthopaedy, the patient was submitted to the radiography of normal and lateral full-length vertebral column scans and the total magnetic resonance imaging (MRI) scans; then, the idiopathic scoliosis model was constructed by the 3D finite element method, and the 3D finite element software utilized in the process of model construction included Mimics software, Geomagic Studio 12 software, and Unigraphic 8.0 (UG 8.0) software; in addition, PVCR orthopaedy was utilized to correct the scoliosis of the patient, and the biomechanical parameters, such as orthodontic force, vertebral body displacement, orthopedic rod stress, stress on the pin-bone interface of the vertebral body surface, and the stress on the intervertebral disc, were studied.ResultsThe 3D effective finite element model of scoliosis was successfully constructed by the Mimics software, the Geomagic Studio 12 software, and the UG 8.0 software, and the effectiveness was tested. PVCR orthopaedy could effectively solve the problem of scoliosis. The magnitude of the orthodontic force that a patient needed depended on the physical conditions and the personal orthodontic requirements of the patient. The maximum vertebral body displacement on the X-axis was the vertebral body L1, the maximum displacement on the Y-axis was the vertebral body T3, the maximum displacement on the Z-axis was the vertebral body T1, and the rang of orthopedic rod stress was 0.0050214e7 MPa to 0.045217e7 MPa, in which the maximum stress of 2 vertebral bodies in, above, and below the osteotomy area reached 0.045217e7 MPa, the stress on the pin-bone interface of the T10 vertebral body surface reached 11.83 MPa, and the stress of T8/T9 intervertebral disc reached 13.84 MPa.ConclusionThe 3D finite element model based on 3D finite element software was highly efficient, and its numerical simulation was accurate, which was important for the subsequent biomechanical analysis of PVCR orthopaedy. In addition, the vertebral stress of PVCR orthopaedy was different in each body part, which was mainly affected by the applied orthodontic force and the sites of the orthodontic area.
Keywords:Scoliosis  Stress  Model  Vertebral body  PVCR
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号