首页 | 本学科首页   官方微博 | 高级检索  
     


Development and validation of a high performance liquid chromatography-tandem mass spectrometry for the determination of etodolac in human plasma
Authors:Lee Hyun-Soo  Kang Il-Mo  Lee Heon-Woo  Seo Ji-Hyung  Ryu Ju-Hee  Choi Sang-Jun  Lee Myung-Jae  Jeong Seo-Young  Cho Young-Wuk  Lee Kyung-Tae
Affiliation:College of Pharmacy, Kyung-Hee University, Hoegi-Dong, Dongdaemun-Ku, Seoul 130-701, Republic of Korea.
Abstract:
A simple and specific method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the determination of etodolac in human plasma, using indomethacin as an internal standard (IS). Chromatographic separation was performed isocratically using a Capcellpak MGII C(18) column with 65% acetonitrile and 35% water containing 10mM ammonium formate (adjusted to pH 3.5 with formic acid). Acquisition was performed in multiple reaction monitoring (MRM) mode by monitoring the transitions: m/z 287.99>172.23 for etodolac and m/z 357.92>139.01 for IS. The method was validated to determine its selectivity, linearity, sensitivity, precision, accuracy, recovery and stability. The limit of quantitation (LLOQ) was 0.1microg/mL with a relative standard deviation of less than 15%. The devised method provides an accurate, precise and sensitive tool for determining etodolac levels in plasma.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏