Proteome wide evaluation of the separation ability of hydrophobic interaction chromatography by fluorescent dye binding analysis
Authors:Celeste C Ibarra‐Herrera  Rami Reddy‐Vennapusa  Marco Rito‐Palomares  Marcelo Fernández‐Lahore
Institution:1. Downstream Bioprocessing Laboratory, School of Engineering and Science, Jacobs University, , Bremen, D‐28759 Germany;2. Centro de Biotecnología‐FEMSA, Departamento de Biotecnología e Ingeniería de Alimentos, Tecnológico de Monterrey, , Monterrey, 64849 Mexico;3. Manufacturing Technologies Department, Shantha Biotechnics (A Sanofi Company), , Hyderabad, 50140 India
Abstract:Hydrophobic interaction chromatography (HIC) is an important tool in the industrial purification of proteins from various sources. The HIC separation behavior of individual (or model) proteins has been widely researched by others. On the contrary, this study focused on the fractionation ability of HIC when it is challenged with whole proteomes. The impact of the nature of three different proteomes, that is, yeast, soybean, and Chinese hamster ovary cells, on HIC separation was investigated. In doing so, chromatography fractions obtained under standardized conditions were evaluated in terms of their overall hydrophobicity—as measured by fluorescence dye binding. This technique allowed for the calculation of an average protein surface hydrophobicity (S0) for each fraction; a unique correlation between S0 and the observed chromatographic behavior was established in each case. Following a similar strategy, the effect of three different ligands (polypropylene glycol, phenyl, and butyl) and two adsorbent particle sizes (65 and 100 µm) on the chromatographic behavior of the yeast proteome was evaluated. As expected, the superficial hydrophobicity of the proteins eluted is correlated with the salt concentration of its corresponding elution step. The findings reveled how—and in which extent—the type of ligand and the size of the beads actually influenced the fractionation of the complex biological mixture. Summarizing, the approach presented here can be instrumental to the study of the performance of chromatography adsorbents under conditions close to industrial practice and to the development of downstream processing strategies. Copyright © 2013 John Wiley & Sons, Ltd.
Keywords:chromatography  adsorption  hydrophobicity  proteome  ligand  particle size
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号