Release kinetics of high-sensitivity cardiac troponins I and T and troponin T upstream open reading frame peptide (TnTuORF) in clinically induced acute myocardial infarction
Authors:Christoph Liebetrau  Luise Gaede  J. Sebastian Wolter  Julia Homann  Alexander Meyer  Oliver Dörr
Affiliation:1. Department of Cardiology, Kerckhoff Heart and Thorax Center, Bad Nauheim, Germany;2. DZHK (German Center for Cardiovascular Research), partner site RheinMain, Frankfurt am Main, Germany;3. Department of Cardiac Surgery, Kerckhoff Heart and Thorax Center, Bad Nauheim, Germany;4. Medical Clinic I, Cardiology and Angiology, University of Giessen, Giessen, Germany
Abstract:Context: Troponin T upstream open reading frame peptide (TnTuORF) may be useful as a novel biomarker in acute cardiac syndromes.

Objective: The study examined the early release kinetics of TnTuORF.

Materials and methods: We analyzed the time course of the release of cardiac troponins I and T and TnTuORF in patients (n?=?31) with hypertrophic obstructive cardiomyopathy undergoing transcoronary ablation of septal hypertrophy (TASH).

Results: Fifteen minutes after TASH, the levels of both troponins increased significantly (cTnT median: 18?ng/L versus 27?ng/L; cTnI median: 15?ng/L versus 25?ng/L). TnTuORF showed no variation.

Discussion: We observed a significantly greater increase in cTnI compared with cTnT.

Conclusion: Our results demonstrate that troponin assays allow early detection of myocardial injury, whereas TnTuORF levels remain unchanged in this setting.

Keywords:Acute coronary syndrome  HOCM  TASH