Abstract: | A rapid and sensitive high-performance liquid chromatography assay method was developed to determine serum fluoxetine and norfluoxetine levels by single extraction of 0.1 ml of serum with sodium hydroxide. The mobile phase (55% acetonitrile–45% distilled water containing 10 mM aqueous triethylamine) was used to separate fluoxetine and norfluoxetine (25–1000 ng/ml, using clomipramine as the internal standard) by ultraviolet detection at 226 nm. The inter- and intra-day variabilities of fluoxetine and norfluoxetine were 13–18%, and the recoveries of both drugs exceeded 89%. This assay method was applied to a pharmacokinetic disposition study of fluoxetine in mice. |