首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Application of higher order statistics for atrial arrhythmia classification
Authors:Roshan Joy Martis  U Rajendra Acharya  Hari Prasad  Chua Kuang Chua  Choo Min Lim  Jasjit S Suri
Institution:1. Department of Electronics and Computer Engineering, Ngee Ann Polytechnic, Singapore 599489, Singapore;2. Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Malaysia;3. Department of Physiology, Johns Hopkins University, School of Medicine, Baltimore, MD 21205, USA;4. School of Engineering, Ngee Ann Polytechnic, Singapore 599489, Singapore;5. Global Biomedical Technologies Inc., Roseville, CA, USA;6. Biomedical Engineering Department, Idaho State University (Affiliated), Pocatello, ID, USA
Abstract:Atrial fibrillation (AF) and atrial flutter (AFL) are the two common atrial arrhythmia encountered in the clinical practice. In order to diagnose these abnormalities the electrocardiogram (ECG) is widely used. The conventional linear time and frequency domain methods cannot decipher the hidden complexity present in these signals. The ECG is inherently a non-linear, non-stationary and non-Gaussian signal. The non-linear models can provide improved results and capture minute variations present in the time series. Higher order spectra (HOS) is a non-linear dynamical method which is highly rugged to noise. In the present study, the performances of two methods are compared: (i) 3rd order HOS cumulants and (ii) HOS bispectrum. The 3rd order cumulant and bispectrum coefficients are subjected to dimensionality reduction using independent component analysis (ICA) and classified using classification and regression tree (CART), random forest (RF), artificial neural network (ANN) and k-nearest neighbor (KNN) classifiers to select the best classifier. The ICA components of cumulant coefficients have provided the average accuracy, sensitivity, specificity and positive predictive value of 99.50%, 100%, 99.22% and 99.72% respectively using KNN classifier. Similarly, the ICA components of HOS bispectrum coefficients have yielded the average accuracy, sensitivity, specificity and PPV of 97.65%, 98.16%, 98.75% and 99.53% respectively using KNN. So, the ICA performed on the 3rd order HOS cumulants coupled with KNN classifier performed better than the HOS bispectrum method. The proposed methodology is robust and can be used in mass screening of cardiac patients.
Keywords:Electrocardiogram  Atrial fibrillation  Atrial flutter  Classifier  Higher order spectra  Independent component analysis
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号