Analysis of inter-/intra-E-plate repeatability in the real-time cell analyzer
Authors:Jiao Chen  Tianhong Pan  Bharathi Devi Devendran  Zhankun Xi  Swanand Khare  Biao Huang  Weiping Zhang  Stephan Gabos  Dorothy Yu Huang  Can Jin
Institution:1. School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China;2. School of Electronics and Electrical Engineering, Changzhou College of Information Technology, Changzhou, Jiangsu 213164, China;3. Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 2G6, Canada;4. Department of Mathematics, Indian Institute of Technology, Kharagpur 721302, India;5. Alberta Health, Edmonton, Alberta T5J 1S6, Canada;6. Division of Analytical and Environmental Toxicology, University of Alberta, Edmonton, Alberta T6G 2G3, Canada;g Alberta Centre for Toxicology, University of Calgary, Calgary, Alberta T2N 4N1, Canada;h Department of Biology, ACEA Biosciences, San Diego, CA 92121, USA
Abstract:Over the past decade, the real-time cell analyzer (RTCA) has provided a good tool to the cell-based in vitro assay. Unlike the traditional systems that label the target cells with luminescence, fluorescence, or light absorption, RTCA monitors cell properties using noninvasive and label-free impedance measuring. However, realization of the maximum value of RTCA for applications will require assurance of within-experiment repeatability, day-to-day repeatability, and robustness to variations in conditions that might occur from different experiments. In this article, the performance and variability of RTCA is evaluated and a novel repeatability index (RI) is proposed to analyze the intra-/inter-E-plate repeatability of RTCA. The repeatability assay involves six cell lines and two media (water H2O] and dimethyl sulfoxide DMSO]). First, six cell lines are exposed to the media individually, and time-dependent cellular response curves characterized as a cell index (CI) are recorded by RTCA. Then, the variations along sampling time and among repeated tests are calculated and RI values are obtained. Finally, a discriminating standard is set up to evaluate the degree of repeatability. As opposed to the standardized methodologies, it is shown that the presented index can give the quantitative evaluation for repeatability of RTCA within E-plate and variation on different days.
Keywords:Repeatability  Repeatability index (RI)  Percentage coefficient of variation (%CV)  Real-time cell analyzer (RTCA)  Cytotoxicity
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号