首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Registration of 6-DOFs electrogoniometry and CT medical imaging for 3D joint modeling
Authors:Van Sint Jan S  Salvia P  Hilal I  Sholukha V  Rooze M  Clapworthy G
Institution:Department of Anatomy (CP 619), University of Brussels, Lennik Street 808, 1070 Brussels, Belgium. sintjans@ulb.ac.be
Abstract:The paper describes a method in which two data-collecting systems, medical imaging and electrogoniometry, are combined to allow the accurate and simultaneous modeling of both the spatial kinematics and the morphological surface of a particular joint. The joint of interest (JOI) is attached to a Plexiglas jig that includes four metallic markers defining a local reference system (R(GONIO)) for the kinematics data. Volumetric data of the JOI and the R(GONIO) markers are collected from medical imaging. The spatial location and orientation of the markers in the global reference system (R(CT)) of the medical-imaging environment are obtained by applying object-recognition and classification methods on the image dataset. Segmentation and 3D isosurfacing of the JOI are performed to produce a 3D model including two anatomical objects-the proximal and distal JOI segments. After imaging, one end of a custom-made 3D electrogoniometer is attached to the distal segment of the JOI, and the other end is placed at the R(GONIO) origin; the JOI is displaced and the spatial kinematics data is recorded by the goniometer. After recording, data registration from R(GONIO) to R(CT) occurred prior to simulation. Data analysis was performed using both joint coordinate system (JCS) and instantaneous helical axis (IHA).Finally, the 3D joint model is simulated in real time using the experimental kinematics data. The system is integrated into a computer graphics interface, allowing free manipulation of the 3D scene.The overall accuracy of the method has been validated with two other kinematics data collection methods including a 3D digitizer and interpolation of the kinematics data from discrete positions obtained from medical imaging. Validation has been performed on both superior and inferior radio-ulna joints (i.e. prono-supination motion). Maximal RMS error was 1 degrees and 1.2mm on the helical axis rotation and translation, respectively. Prono-supination of the forearm showed a total rotation of 132 degrees for 0.8mm of translation. The method reproducibility using JCS parameters was in average 1 degrees (maximal deviation=2 degrees ) for rotation, and 1mm (maximal deviation=2mm) for translation. In vitro experiments have been performed on both knee joint and ankle joint. Averaged JCS parameters for the knee were 109 degrees, 17 degrees and 4 degrees for flexion, internal rotation and abduction, respectively. Averaged maximal translation values for the knee were 12, 3 and 4mm posteriorly, medially and proximally, respectively. Averaged JCS parameters for the ankle were 43 degrees, 9 degrees and 3 degrees for plantarflexion, adduction and internal rotation, respectively. Averaged maximal translation values for the ankle were 4, 2 and 1mm anteriorly, medially and proximally, respectively.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号