首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Synthesis and biological properties of 7alpha-cyano derivatives of the (17alpha,20E/Z)-[125I]iodovinyl- and 16alpha-[125I]iodo-estradiols
Authors:Ali Hasrat  Rousseau Jacques  Paquette Benoit  Dubé Charlotte  Marko Bernadette  van Lier Johan E
Institution:Department of Nuclear Medicine and Radiobiology, Faculty of Medicine, Université de Sherbrooke, Sherbrooke, Que., Canada J1H 5N4.
Abstract:The synthesis, receptor binding affinity, estrogenic potency and tissue distribution of the 7alpha-cyano derivatives of the (17alpha,20E/Z)-125I]iodovinyl-(CIVE) and 16alpha-125I]iodo-estradiols (CIE) are reported. The iodovinyl derivatives were prepared via the (17alpha,20E/Z)-tri-n-butylstannyl intermediates, derived from the addition of tri-n-butyl tin hydride to the 17alpha-ethynyl group of the 7alpha-cyano-17alpha-ethynylestradiol, using triethylborane as a catalyst. The no-carrier-added 125I]-CIVE isomers were prepared via the same stereospecific reaction. 125I]-CIE was prepared from 7alpha-cyano-16beta-bromoestradiol via halogen exchange with Na125I. Addition of the 7alpha-cyano group to 16alpha-iodoestradiol did not affect estrogen receptor binding affinity (RBA of CIE is 115). However the estrogenic potential of CIE, as measured by the capacity to stimulate the expression of the pS2 gene, was reduced to 1% as compared to that of estradiol. Addition of a 7alpha-cyano group to the (17alpha,20E/Z)-IVE isomers reduced the RBA to 21 and 36, respectively, while the estrogenic potential was reduced to 2-3% of that of estradiol. Uterus uptake in immature rats of the 125I-labeled CIVE 20E-isomer and the 16alpha-iodo CIE peaked at 0.5h post injection while the (17alpha,20Z)-CIVE isomer showed a maximum only past 5h post injection. Uptake of all three 125I-labeled 7alpha-cyanoestrogens was suppressed by the co-injection of non-radioactive estradiol confirming the role of estrogen receptors in the localization process. Uterus retention pattern differ substantially from those of the analogues 7alpha-methylestrogens, which were previously shown to give high maximum 125I-uptake values at 2h post injection. Overall our data indicate that addition of a 7alpha-cyano group to 123I-labeled estrogens does not improve their potential to serve as SPECT agents for the imaging of estrogen receptor densities in breast cancer.
Keywords:7α-Cyanoestradiol derivatives  16α-Iodoestradiol  (17α  20E/Z)-iodovinylestradiol derivatives  Breast tumor imaging
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号