An inverse finite element method for determining the anisotropic properties of the cornea |
| |
Authors: | T. D. Nguyen and B. L. Boyce |
| |
Affiliation: | (1) Structural Biophysics Research Group, School of Optometry and Vision Sciences, Cardiff University, Maindy Road, Cardiff, CF24 4LU, UK |
| |
Abstract: | An inverse finite element method was developed to determine the anisotropic properties of bovine cornea from an in vitro inflation experiment. The experiment used digital image correlation (DIC) to measure the three-dimensional surface geometry and displacement field of the cornea at multiple pressures. A finite element model of a bovine cornea was developed using the DIC measured surface geometry of the undeformed specimen. The model was applied to determine five parameters of an anisotropic hyperelastic model that minimized the error between the measured and computed surface displacement field and to investigate the sensitivity of the measured bovine inflation response to variations in the anisotropic properties of the cornea. The results of the parameter optimization revealed that the collagen structure of bovine cornea exhibited a high degree of anisotropy in the limbus region, which agreed with recent histological findings, and a transversely isotropic central region. The parameter study showed that the bovine corneal response to the inflation experiment was sensitive to the shear modulus of the matrix at pressures below the intraocular pressure, the properties of the collagen lamella at higher pressures, and the degree of anisotropy in the limbus region. It was not sensitive to a weak collagen anisotropy in the central region. |
| |