Abstract: | Dielectric spectroscopy is a non-invasive contact technique that permits the in vivo measurement of the specific electrical properties of biological tissue induced by an external electrical field. Permittivity, relaxation time and specific conductivity as a function of corneal hydration (wet weight/dry weight) and temperature were measured in 10 porcine corneas. Variation of tissue hydration has a minor influence on the signal, with a significant variation of the signal being detectable only for relatively dry tissue. A much greater influence was found for temperature, in particular on relaxation times. Dielectric spectroscopy provides us with an opportunity to detect structural, in particular temperature-induced, changes in living tissue. In the frequency range investigated, hydration has only a small influence on the dielectric properties of the tissue. |