首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Dosimetric analysis of Tomotherapy-based intracranial stereotactic radiosurgery of brain metastasis
Institution:2. Division of Radiation Oncology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand;3. Northern Thai Research Group of Radiation Oncology (NTRG-RO), Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand;2. Sir Charles Gairdner Hospital, Perth, Australia;3. Princess Alexandra Hospital, Brisbane, Australia;4. Royal Brisbane and Women''s Hospital, Brisbane, Australia;5. 5D Clinics, Perth, Australia;11. Herston Biofabrication Institute, Brisbane, Australia;1. School of Information Technology and Electrical Engineering, University of Queensland, St Lucia, Brisbane, Australia;2. School of Chemistry and Physics, Queensland University of Technology, Brisbane, Australia
Abstract:PurposeThis paper analyzes Tomotherapy-based intracranial stereotactic radiosurgery (HTSRS) of brain metastasis targeting two end-points: 1) evaluation of dose homogeneity, conformity and gradient scores for single and multiple lesions and 2) assay of dosimetric criticality of completion of HTSRS procedures.Methods42 treatment plans of 33 patients (53 brain lesions) treated with HTSRS were analyzed. Dose to healthy brain, homogeneity, conformity and gradient indexes were evaluated for each lesion. Influence of Field Length and multiple lesions cross-talk effect were assessed. Treatment interruption and completion was investigated using radiochromic films in order to examine the delivered dose and its robustness to patient intrafraction movement.ResultsThe average dose homogeneity index was 1.04 ± 0.02 (SD). Average dose conformity and gradient score indexes were 1.4 ± 0.2 and 50 ± 14 respectively. We found a strong correlation of the dose to healthy brain and conformity and gradient indexes with target(s) volume for which analytical functions were obtained. Field Length and cross-talk effect were significantly correlated with poor gradient scores, but were found not to affect dose conformity.ConclusionsHomogeneity and conformity of HTSRS plans achieved excellent scores, while dose falloff and dose to healthy brain were slightly larger when compared with non-coplanar SRS techniques. Care should be given if treating large (>3 cc) or multiple near in-plane lesions in order to reduce dose to healthy brain. Analysis of interrupted treatments suggests splitting HTSRS treatments in two consecutive fractions in order to prevent target miss and overdosage due to patient intrafraction movement.
Keywords:Tomotherapy  Stereotactic treatment  Brain radiosurgery  Conformity index  Dose gradient  Radionecrosis  Treatment interruption
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号