首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Targeted Deposition of Antibodies on a Multiplex CMOS Microarray and Optimization of a Sensitive Immunoassay Using Electrochemical Detection
Authors:John Cooper  Nina Yazvenko  Kia Peyvan  Karl Maurer  Chris R Taitt  Wanda Lyon  David L Danley
Institution:1. CombiMatrix Corporation, Mukilteo, Washington, United States of America.; 2. United States Naval Research Laboratory, Washington, D.C., United States of America.; 3. Air Force Research Laboratory, Dayton, Ohio, United States of America.;Charité-Universitätsmedizin Berlin, Germany
Abstract:

Background

The CombiMatrix ElectraSense® microarray is a highly multiplex, complementary metal oxide semiconductor with 12,544 electrodes that are individually addressable. This platform is commercially available as a custom DNA microarray; and, in this configuration, it has also been used to tether antibodies (Abs) specifically on electrodes using complementary DNA sequences conjugated to the Abs.

Methodology/Principal Findings

An empirical method is described for developing and optimizing immunoassays on the CombiMatrix ElectraSense® microarray based upon targeted deposition of polypyrrole (Ppy) and capture Ab. This process was automated using instrumentation that can selectively apply a potential or current to individual electrodes and also measure current generated at the electrodes by an enzyme-enhanced electrochemical (ECD) reaction. By designating groups of electrodes on the array for different Ppy deposition conditions, we determined that the sensitivity and specificity of a sandwich immunoassay for staphylococcal enterotoxin B (SEB) is influenced by the application of different voltages or currents and the application time. The sandwich immunoassay used a capture Ab adsorbed to the Ppy and a reporter Ab labeled for fluorescence detection or ECD, and results from these methods of detection were different.

Conclusions/Significance

Using Ppy deposition conditions for optimum results, the lower limit of detection for SEB using the ECD assay was between 0.003 and 0.01 pg/ml, which represents an order of magnitude improvement over a conventional enzyme-linked immunosorbant assay. In the absence of understanding the variables and complexities that affect assay performance, this highly multiplexed electrode array provided a rapid, high throughput, and empirical approach for developing a sensitive immunoassay.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏