首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Prospective Evaluation of Three Rapid Diagnostic Tests for Diagnosis of Human Leptospirosis
Authors:Marga G A Goris  Mariska M G Leeflang  Martin Loden  Jiri F P Wagenaar  Paul R Klatser  Rudy A Hartskeerl  Kimberly R Boer
Institution:1. KIT Biomedical Research, Royal Tropical Institute (KIT), Amsterdam, The Netherlands.; 2. Department of Clinical Epidemiology and Biostatistics, Academic Medical Center, Amsterdam, The Netherlands.; 3. Department of Global Health, Academic Medical Center, Amsterdam, The Netherlands.; Universidad Peruana Cayetano Heredia, Peru,
Abstract:

Background

Diagnosis of leptospirosis by the microscopic agglutination test (MAT) or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs) can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively.

Methodology

During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture) on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1st submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness.

Results

The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1st submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB), but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB).

Conclusions

All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号