首页 | 本学科首页   官方微博 | 高级检索  
     


Mean aortic pressure is the geometric mean of systolic and diastolic aortic pressure in resting humans.
Authors:Denis Chemla  Isabelle Antony  Karen Zamani  Alain Nitenberg
Affiliation:Service de Physiologie Cardio-Respiratoires, Université de Paris Sud 11, Centre Hospitalier Universitaire de Bicêtre, Le Kremlin-Bicêtre, France. denis.chemla@bct.ap-hop-paris.fr
Abstract:
The aim of our study was twofold: 1) to establish a mathematical link between mean aortic pressure (MAP) and systolic (SAP) and diastolic aortic pressures (DAP) by testing the hypothesis that either the geometric mean or the harmonic mean of SAP and DAP were reliable MAP estimates; and 2) to critically evaluate three empirical formulas recently proposed to estimate MAP. High-fidelity pressures were recorded at rest at the aortic root level in controls (n = 31) and in subjects with various forms of cardiovascular diseases (n = 108). The time-averaged MAP and the pulse pressure (PP = SAP - DAP) were calculated. The MAP ranged from 66 to 160 mmHg [mean = 107.9 mmHg (SD 18.2)]. The geometric mean, i.e., the square root of the product of SAP and DAP, furnished a reliable estimate of MAP [mean bias = 0.3 mmHg (SD 2.7)]. The harmonic mean was inaccurate. The following MAP formulas were also tested: DAP + 0.412 PP (Meaney E, Alva F, Meaney A, Alva J, and Webel R. Heart 84: 64, 2000), DAP + 0.33 PP + 5 mmHg [Chemla D, Hébert JL, Aptecar E, Mazoit JX, Zamani K, Frank R, Fontaine G, Nitenberg A, and Lecarpentier Y. Clin Sci (Lond) 103: 7-13, 2002], and DAP + [0.33 + (heart rate x 0.0012)] PP (Razminia M, Trivedi A, Molnar J, Elbzour M, Guerrero M, Salem Y, Ahmed A, Khosla S, Lubell DL. Catheter Cardiovasc Interv 63: 419-425, 2004). They all provided accurate and precise estimates of MAP [mean bias = -0.2 (SD 2.9), -0.3 (SD 2.7), and 0.1 mmHg (SD 2.9), respectively]. The implications of the geometric mean pressure strictly pertained to the central (not peripheral) level. It was demonstrated that the fractional systolic (SAP/MAP) and diastolic (DAP/MAP) pressures were reciprocal estimates of aortic pulsatility and that the SAP times DAP product matched the total peripheral resistance times cardiac power product. In conclusion, although the previously described thumb-rules applied, the "geometric MAP" appears more valuable as it established a simple mathematical link between the steady and pulsatile component of aortic pressure.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号