Determination of vertilmicin in rat serum by high-performance liquid chromatography using 1-fluoro-2,4-dinitrobenzene derivatization
Authors:Zhou Maojin  Wei Guangli  Liu Youping  Sun Yuming  Xiao Shuhua  Lu Long  Liu Changxiao  Zhong Dafang
Institution:Tianjin Key Laboratory of Drug Metabolism and Pharmacokinetics, Tianjin Institute of Pharmaceutical Research, 308 Anshan West Road, Tianjin 300193, PR China.
Abstract:A procedure for the high-performance liquid chromatographic determination of vertilmicin in rat serum was described using pre-column derivatization. The serum proteins were precipitated with acetonitrile and vertilmicin in the supernatant was derivatized with 1-fluoro-2,4-dinitrobenzene. Etimicin was selected as the internal standard. The mobile phase consisted of methanol--20mM ammonium acetate (80:20, v/v), and flow-rate was 0.9 ml/min. Ultraviolet detection was set at 365 nm. The reaction products were chromatographed on a C(18) column kept at 40 degrees C. A good linearity was found in the range of 0.5-250 microg/ml. Both intra- and inter-day precisions of vertilmicin, expressed as the relative standard deviation, were less than 7.4%. Accuracy, expressed as the relative error, ranged from -0.1 to 3.6%. The mean absolute recovery of vertilmicin at three different concentrations was 92.5%. Serum volumes of 50 microl were sufficient for the determination of vertilmicin. The method was proved suitable for the pharmacokinetic study of vertilmicin in rats.
Keywords:Derivatization  LC  Vertilmicin  1-Fluoro-2  4-dinitrobenzene