首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Evaluation of an intact,an ACL-deficient,and a reconstructed human knee joint finite element model
Authors:Achilles Vairis  George Stefanoudakis  Markos Petousis  Nectarios Vidakis  Andreas-Marios Tsainis  Betina Kandyla
Institution:1. Mechanical Engineering Department, Technological Education Institute of Crete, Estavromenos, 71004 Heraklion, Crete, Greece;2. Creta Interclinic Hospital, Minoos 63 Str., 71304 Heraklion, Crete, Greece;3. 3 Karistou Rd, Athens 11523, Greece
Abstract:The human knee joint has a three-dimensional geometry with multiple body articulations that produce complex mechanical responses under loads that occur in everyday life and sports activities. Understanding the complex mechanical interactions of these load-bearing structures is of use when the treatment of relevant diseases is evaluated and assisting devices are designed. The anterior cruciate ligament (ACL) in the knee is one of four main ligaments that connects the femur to the tibia and is often torn during sudden twisting motions, resulting in knee instability. The objective of this work is to study the mechanical behavior of the human knee joint and evaluate the differences in its response for three different states, i.e., intact, ACL-deficient, and surgically treated (reconstructed) knee. The finite element models corresponding to these states were developed. For the reconstructed model, a novel repair device was developed and patented by the author in previous work. Static load cases were applied, as have already been presented in a previous work, in order to compare the calculated results produced by the two models the ACL-deficient and the surgically reconstructed knee joint, under the exact same loading conditions. Displacements were calculated in different directions for the load cases studied and were found to be very close to those from previous modeling work and were in good agreement with experimental data presented in literature. The developed finite element model for both the intact and the ACL-deficient human knee joint is a reliable tool to study the kinematics of the human knee, as results of this study show. In addition, the reconstructed human knee joint model had kinematic behavior similar to the intact knee joint, showing that such reconstruction devices can restore human knee stability to an adequate extent.
Keywords:finite element modeling  knee ligament repair  tendon graft  anterior cruciate ligament  biomechanics
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号