Development and validation of a liquid chromatography and tandem mass spectrometry method for determination of roscovitine in plasma and urine samples utilizing on-line sample preparation |
| |
Authors: | Vita Marina Skansen Patrik Hassan Moustapha Abdel-Rehim Mohamed |
| |
Affiliation: | Department of Medicine, Division of Hematology, Laboratory of Hematology, Karolinska University Hospital, Huddinge, 141 86 Stockholm, Sweden. |
| |
Abstract: | ![]() Roscovitine, a purine analogue that selectively inhibits cyclin-dependent kinases, has been considered as a potential anti-tumor drug. The determination of roscovitine in plasma and urine was performed using microextraction in packed syringe as on-line sample preparation method with liquid chromatography and tandem mass spectrometry. The sampling sorbent utilized was polystyrene polymer. 2H3-lidocaine was used as internal standard. The limit of detection for roscovitine was as low as 0.5 ng/mL and the lower limit of quantification was 1.0 ng/mL. The accuracy and precision values of quality control samples were between +/-15% and < or =11%, respectively. The calibration curve was obtained within the concentration range 0.5-2000 ng/mL in both plasma and urine. The regression correlation coefficients for plasma and urine samples were > or =0.999 for all runs. The present method is miniaturized and fully automated and can be used for pharmacokinetic and pharmacodynamic studies. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|