首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Direct measurement of static chest wall compliance in animal and human neonates
Authors:Davis  G M; Coates  A L; Papageorgiou  A; Bureau  M A
Institution:McGill University-Montreal Children's Hospital Research Institute, Quebec, Canada.
Abstract:The measurement of pulmonary mechanics has been developed extensively for adults, and these techniques have been applied directly to neonates and infants. However, the compliant chest wall of the infant frequently predisposes to chest wall distortion, especially when there is a low dynamic lung compliance (CL,dyn). We describe a technique of directly measuring the static chest wall compliance (Cw,st), developed initially in the newborn lamb and subsequently applied to the premature neonate with chest wall distortion. The mean CL,dyn in seven intubated newborn lambs in normoxia was 2.45 +/- 0.41 ml.cmH2O-1.kg-1, whereas Cw,st was 11.81 +/- 0.25 ml.cmH2O-1.kg-1. These values did not change significantly in seven animals breathing through a tight-fitting face mask or with hypercapnia-induced tachypnea. For the eight premature infants the mean CL,dyn was 1.35 +/- 0.36 ml.cmH2O-1.kg-1, whereas the mean Cw,st was 3.16 +/- 1.01 ml.cmH2O-1.kg-1. This study shows that, under relaxed conditions when measurements of static compliance are performed, the chest wall is more compliant than the lung. The measurement of Cw,st may thus be used to determine the contribution of the respiratory musculature in stabilizing the chest wall.
Keywords:
点击此处可从《Journal of applied physiology (Bethesda, Md. : 1985)》浏览原始摘要信息
点击此处可从《Journal of applied physiology (Bethesda, Md. : 1985)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号