Effect of accelerated electron beam on mechanical properties of human cortical bone: influence of different processing methods |
| |
Authors: | Artur Kaminski Ewelina Grazka Anna Jastrzebska Joanna Marowska Grzegorz Gut Artur Wojciechowski Izabela Uhrynowska-Tyszkiewicz |
| |
Affiliation: | Department of Transplantology and Central Tissue Bank, Medical University of Warsaw, ul. Chalubinskiego 5, 02-004, Warsaw, Poland, artur.kaminski@wum.edu.pl. |
| |
Abstract: | Accelerated electron beam (EB) irradiation has been a sufficient method used for sterilisation of human tissue grafts for many years in a number of tissue banks. Accelerated EB, in contrast to more often used gamma photons, is a form of ionizing radiation that is characterized by lower penetration, however it is more effective in producing ionisation and to reach the same level of sterility, the exposition time of irradiated product is shorter. There are several factors, including dose and temperature of irradiation, processing conditions, as well as source of irradiation that may influence mechanical properties of a bone graft. The purpose of this study was to evaluate the effect e-beam irradiation with doses of 25 or 35?kGy, performed on dry ice or at ambient temperature, on mechanical properties of non-defatted or defatted compact bone grafts. Left and right femurs from six male cadaveric donors, aged from 46 to 54?years, were transversely cut into slices of 10?mm height, parallel to the longitudinal axis of the bone. Compact bone rings were assigned to the eight experimental groups according to the different processing method (defatted or non-defatted), as well as e-beam irradiation dose (25 or 35?kGy) and temperature conditions of irradiation (ambient temperature or dry ice). Axial compression testing was performed with a material testing machine. Results obtained for elastic and plastic regions of stress-strain curves examined by univariate analysis are described. Based on multivariate analysis, including all groups, it was found that temperature of e-beam irradiation and defatting had no consistent significant effect on evaluated mechanical parameters of compact bone rings. In contrast, irradiation with both doses significantly decreased the ultimate strain and its derivative toughness, while not affecting the ultimate stress (bone strength). As no deterioration of mechanical properties was observed in the elastic region, the reduction of the energy absorption capacity of irradiated bone rings apparently resulted from changes generated by irradiation within the plastic strain region. |
| |
Keywords: | |
本文献已被 PubMed SpringerLink 等数据库收录! |
|