首页 | 本学科首页   官方微博 | 高级检索  
     


Lateral mobility of lipid analogues and GPI-anchored proteins in supported bilayers determined by fluorescent bead tracking
Authors:Martin Fein  Jay Unkeless  Frank Y. S. Chuang  Massimo Sassaroli  Rui da Costa  Heikki Väänänen  Josef Eisinger
Affiliation:(1) Department of Biochemistry, Mount Sinai School of Medicine, 10029 New York, New York;(2) Department of Biology, Bronx Community College-CUNY, 10453 New York, New York;(3) Department of Physiology and Biophysics, Mount Sinai School of Medicine, 10029 New York
Abstract:
Lipid analogues and glycosylphosphati-dylinositol (GPI)-anchored proteins incorporated in glass-supported phospholipid bilayers (SBL) were coupled to small (30 nm diameter) fluorescent beads whose motion in the liquid phase was tracked by intensified fluorescence video microscopy. Streptavidin (St), covalently attached to the carboxyl modified surface of the polystyrene bead, bound either the biotinylated membrane component, or a biotinylated monoclonal antibody (mAb) directed against a specific membrane constituent. The positions of the beads tethered to randomly diffusing membrane molecules were recorded at 0.2 sec intervals for about l min. The mean square displacement (rhov) of the beads was found to be a linear function of diffusion time t, and the diffusion coefficient, D, was derived from the relation, rhov(t) = 4Dt. The values of D for biotinylated phosphatidylethanolamine (Bi-PE) dispersed in an egg lecithin: cholesterol (80:20%) bilayer obtained by this methodology range from 0.05 to 0.6 mgrm2/sec with an average of langDrang = 0.26 mgrm2/sec, similar to the value of langDrang = 0.24 mgrm2/sec for fluorescein-conjugated phosphati-dylethanolamine (Fl-PE) linked to St-coupled beads by the anti-fluorescein mAb 4-4-20 or its Fab fragment. These values of D are comparable to those reported for Fl-PE linked to 30 nm gold particles but are several times lower than that of Fl-PE in the same planar bilayer as measured by fluorescence photobleaching recovery, D = 1.3 mgrm2sec. The mobilities of two GPI-anchored proteins in similar SBL were also determined by use of the appropriate biotinylated mAb and were found to be langDrang = 0.25 and 0.56 mgrm2/sec for the decay accelerating factor (DAF, CD55) and the human FcgammaRIIIB (CD16) receptors, respectively. The methodology described here is suitable for tracking any accessible membrane component.This work was supported by National Institutes of Health grants 1R24 RR05272 and AI-24322.
Keywords:Single particle tracking  Lateral diffusion  Fluorescent beads  Brownian motion  Fluorescence imaging  Membrane fluidity
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号