首页 | 本学科首页   官方微博 | 高级检索  
     


Use of the glucose oxidase system for estimation of oxygen transfer rate in a solid-state bioreactor
Authors:Hua Zhao   Xiaoyong Zhang   Xiaohong Zhou  Zuohu Li
Affiliation:

a State Key Laboratory of Biochemical Engineering, Institute of Chemical Metallurgy, Chinese Academy of Sciences, P.O. Box 353, Beijing 100080, Peoples Republic of China

Abstract:The glucose oxidase system was adapted for estimation of the overall oxygen transfer rate in a periodic pressure oscillating, solid-state bioreactor. Enzyme concentration of 40 ml enzyme preparation L−1 was found adequate to give linear gluconic acid production and attain maximal oxygen absorption rates. At 4 atm and 30°C, the oxygen transfer rate reached 892 mmol kg−1 initial dry matter h−1 in this system, while only 121 mmol kg−1 initial dry matter h−1 was obtained in a conventional static tray bioreactor.
Keywords:Glucose oxidase system   Oxygen transfer rate   Periodic pressure oscillation   Solid-state bioreactor
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏