首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Liquid chromatographic method for detection and quantitation of STI-571 and its main metabolite N-desmethyl-STI in plasma, urine, cerebrospinal fluid, culture medium and cell preparations
Authors:Schleyer E  Pursche S  Köhne C H  Schuler U  Renner U  Gschaidmeier H  Freiberg-Richter J  Leopold T  Jenke A  Bonin M  Bergemann T  le Coutre P  Gruner M  Bornhäuser M  Ottmann O G  Ehninger G
Institution:1. Medizinische Klinik und Poliklinik I an der, Technischen Universität Dresden, Fetscherstr. 48, 01307 Dresden, Germany;2. Medizinische Klinik für Hämatologie und Onkologie, Campus Virchow, Charité, Humboldt Universität Berlin, Berlin, Germany;3. Medizinische Klinik III, Johann Wolfgang Goethe Universität, Frankfurt a.M., Germany;4. Institut für Organische Chemie der Technischen Universität Dresden, Dresden, Germany;5. Novartis Pharma AG, Nürnberg, Germany
Abstract:An isocratic online-enrichment HPLC-assay was developed allowing for the simple and fast separation and quantitation of STI-571 and its main metabolite N-desmethyl-STI (N-DesM-STI) in plasma, urine, cerebrospinal fluid (CSF), culture media and cell preparations in various concentrations using UV-detection at 260 nm. The analytical procedure consists of an online concentration of STI-571 and N-DesM-STI in the HPLC system followed by the elution on a ZirChrom-PBD analytical column. Time of analysis is 40 min including the enrichment time of 5 min. The detection limit is 10 ng/ml in plasma, CSF, culture medium (RPMI) and 25 ng/ml in urine for both STI-571 and N-DesM-STI. The intra-day precision, as expressed by the coefficient of variation (CV), in plasma samples ranges between 1.74 and 8.60% for STI-571 and 1.45 and 8.87% for N-DesM-STI. The corresponding values for urine measurements are 2.17-7.54% (STI-571) and 1.31-9.51% (N-DesM-STI). The inter-day precision analyzed over a 7-month time period was 8.31% (STI-571) or 6.88% (N-DesM-STI) and 16.45% (STI-571) or 14.83% (N-DesM-STI) for a concentration of 1000 ng/ml in plasma and 750 ng/ml in urine, respectively. Moreover, we demonstrate that with an alternative, but more time and labor consuming sample preparation and the implementation of electrochemical detection, a detection limit < 10 ng/ml can be achieved. The method described was used to perform pharmacokinetic measurements of STI-571 and N-desmethyl-STI in patient samples and for kinetic measurements of intracellular STI-571 and N-DesM-STI following in vitro incubation.
Keywords:STI-571  Corresponding author  Tel  : +49-351-458-5617  fax: +49-351-458-5362  
本文献已被 ScienceDirect PubMed 等数据库收录!