首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Shape and tension distribution of the passive rat diaphragm
Authors:Boriek A M  Rodarte J R  Reid M B
Institution:Department of Medicine, Baylor College of Medicine, Houston, Texas 77030, USA. boriek@bcm.tmc.edu
Abstract:We developed an in vitro preparation to investigate shape and stress distribution in the intact rat diaphragm. Our hypothesis was that the diaphragm is anisotropic with smaller compliance in transverse fiber direction than along fibers, and therefore shape change may be small. After the animals were killed (8 rats), the entire diaphragm was excised and fixed into a mold at the insertions. Oxygenated Krebs-Ringer solution was circulated under the diaphragm and perfused over its surface. A total of 20-23 small markers were sutured on the diaphragm surface. At transdiaphragmatic pressure (P(di)) of 3-15 cmH(2)O, curvature was smaller in transverse direction than along fibers. Using finite element analysis we computed membrane tension. At P(di) of 15 cmH(2)O, tension in central tendon was larger than muscle. In costal region maximum principal tension (sigma(1)) is essentially along the fibers and ranged from 6-10 g/cm. Minimum principal tension (sigma(2)) was 0. 3-4 g/cm. In central tendon, sigma(1) was 10-15 g/cm, compared with 4-10 g/cm for sigma(2). The diaphragm was considerably stiffer in transverse fiber direction than along the fibers.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号